1.
  • Digas, Georgios, 1963, et al. (författare)
  • Bioactive cement or ceramic/porous coating vs. conventional cement to obtain early stability of the acetabular cup. Randomised study of 96 hips followed with radiostereometry
  • 2004
  • Ingår i: J Orthop Res. - : Wiley. - 0736-0266. ; 22:5, s. 1035-43
  • Tidskriftsartikel (refereegranskat)abstract
    • Ninety patients (96 hips) scheduled for THA were stratified to fixation of the acetabular component in three main groups of about equal size. Fluoride cement, porous coated press-fit cup with ceramic coating or Palacos cum Gentamicin cement were used. All patients received Spectron EF stem. The migration of the cups and the femoral head penetration into the socket were measured with radiostereometric analysis. At 2 years the choice of fixation did not influence the migration or rotation of the cup. Patients with compromised bone quality showed increased three-dimensional (3D or total) migration. Proximal and 3D penetration rates were increased in cemented compared with the uncemented cups (p<0.001), which probably not could be related to the choice of fixation. Appearance of radiolucent lines was almost equal in the two cemented groups. Uncemented cups had less radiolucent lines at 2 years. Fluoride containing cement or uncemented fixation did not improve the early postoperative stability of the socket.
  •  
2.
  • Digas, Georgios, 1963 (författare)
  • New polymer materials in total hip arthroplasty. Evaluation with radiostereometry, bone densitometry, radiography and clinical parameters
  • 2004
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Aims: To evaluate the outcome of different types of polyethylene, bone cements and one design of uncemented fixation with porous and ceramic coating using radiostereometry, bone densitometry, conventional radiography and clinical parameters.Materials and methods: Study 1: 201 patients were extracted from 5 prospective randomised studies to evaluate femoral head penetration at two years with radiostereometry in four basic designs, cemented Lubinus and Reflection cups, uncemented Trilogy and Reflection cups. Studies II and III. 60 patients (61 hips) were randomised to receive either highly cross-linked or conventional all PE cups. 32 patients with bilateral arthrosis received hybrid THA with highly cross-linked PE on one side and conventional on the contra lateral side. Femoral head penetration and the migration of the cups were evaluated with radiostereometry in the supine and standing positions. DEXA and conventional radiography were used to evaluate the bone mineral density and radiolucencies around the cemented acetabular component. Studies IV and V: 90 patients (97 and 96 hips respectively) were stratified depended on age, gender, diagnosis and preoperative BMD to create 3 main groups of socket fixation. In the first group fluoride containing cement was used, in the second group Palacos cum Gentamicin and in the third hybrid THA with porous coated HA/TCP cup. In the hybrid group the fixation of the femoral component was again randomised to either of the two cements. The results on femoral and acetabular sides are presented separately in studies IV and V, respectively.Results: Study I: Cups with polyethylene sterilized in EtO had almost twice the proximal and 3D penetration rates compared with gamma-sterilized polyethylene. Regression analysis showed that the type of sterilization, age and weight was the most important factors affecting the penetration rate. Studies II and III: In the cemented study the proximal penetration was lower in the study group independent of position at 3 years, while in the hybrid study the penetration was lower in the study group only in the supine position at 2 years. The migration of the cup did not differ between the plastics in both studies. At 2 years the periprosthetic radiolucency and BMD did not differ significantly between the 2 types of PE used in the cemented study. Study IV: The subsidence of the stem did not differ between the groups, but the periprosthetic BMD decreased more in fluoride cement group at 2 years. Conventional radiography revealed higher progression of radiolucent lines in the Palacos group, but only in one region. Study V: The proximal migration of the cup was almost similar in all three groups. The three dimensional migration was increased in patients with osteoporosis. Postoperative radiolucent lines tended to disappear with use of porous coating covered with HA/TCP.Conclusions: Study I: EtO sterilized polyethylene increased the femoral head penetration. Age and weight were also important predictors of the penetration rate. Studies II and III. The highly cross-linked polyethylene decreased the penetration rate mainly after one year probably reflecting less wear. The different mechanical properties of the two types of PE studied did not affect the early fixation of the cemented cup. Study IV: There were no obvious advantage of addition of fluoride to acrylic bone cement when used to fixate the femoral component. Study V: Use of fluoride containing cement or uncemented fixation did not improve the early stability of the socket compared to Palacos with Gentamicin.
  •  
3.
  • Digas, Georgios, 1963, et al. (författare)
  • The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
  • 2004
  • Ingår i: Clin Orthop Relat Res. - 0009-921X. ; :429, s. 6-16
  • Tidskriftsartikel (refereegranskat)abstract
    • The annual wear rate in polyethylene articulations should be 0.1 mm or less to avoid future osteolysis. Highly cross-linked polyethylene shows an 80 to 90% wear reduction in hip simulator testing, but the clinical documentation of this new polyethylene is still inadequate. We evaluated the highly cross-linked polyethylene in two prospective randomized clinical studies. Thirty-two patients (12 men, 20 women; 64 hips) with a median age of 48 years (range, 29-70 years) with bilateral primary or secondary arthrosis of the hip had hybrid total hip arthroplasty with liners made of highly cross-linked polyethylene on one side and conventional polyethylene on the other. Twenty-seven patients in this study have passed 2 years followup. A further group, comprised of 60 patients (61 hips) with a median age of 55 years (range, 35-70 years), was randomized to receive either highly cross-linked polyethylene or conventional cemented all-polyethylene of the same design. Forty-nine of these 60 patients have been observed for 3 years. In both studies all patients received Spectron stems with 28-mm Co-Cr heads. Radiostereometric examinations with the patient supine or standing were done at regular intervals. Wear was measured in the supine position from the first postoperative week, whereas standing examinations were initiated 3 months after the operation. The penetration rate almost was identical in the study and control groups at 6 months after the operation. Thereafter, the penetration rate leveled out in the two groups with highly cross-linked polyethylene. At 2 years the highly cross-linked polyethylene liner showed 62% lower proximal penetration and 31% lower total (three-dimensional) penetration when the patients were examined in supine position. The highly crosslinked all-polyethylene cemented cups showed lower proximal penetration in both positions. The better wear performance of highly cross-linked polyethylene could increase the implant longevity. Longer followup is needed to evaluate if this new material is associated with less occurrence of osteolysis.
  •  
4.
  • Karladani, Abbas, 1954, et al. (författare)
  • Ankle arthrodesis using dowel bone graft and cancellous-bone screws: a mechanical study in cadavers
  • 2004
  • Ingår i: Acta Orthop Scand. - 0001-6470. ; 75:4, s. 471-6
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: There are numerous techniques for ankle arthrodesis. MATERIAL AND METHODS: We studied the stability of an ankle arthrodesis with the use of two cross-screws combined with dowel graft technique in 14 fresh-frozen ankles from amputees. The arthrodesis was performed by a dowel graft technique, in the coronal plane in 7 specimens (group 1) and in the diagonal plane in the remaining 7 (group 2). Allocation into the two groups took place after normalization according to the bone mineral content of the specimens. All ankles were fixed with two 6.5-mm diameter cancellous-bone screws, with the ankle in neutral position. Tibiotalar motion was measured during 5 Nm torque loading in plantar flexion-dorsiflexion, abduction-adduction and eversion-inversion planes of the ankle joint. Two testing sequences were performed and the mean value of both tests in each direction was used for the analysis. RESULTS: In all 3 planes, the torque applied caused more motion with the dowel graft in the coronal plane (group 1) than with the graft in the diagonal plane (group 2). The differences between the two groups were significant for abduction-adduction and eversion-inversion planes. Statistical analysis of differences between the first and second test showed significantly greater stiffness in group 2 than in group 1 in plantar flexion-dorsiflexion torque. INTERPRETATION: The placement of a dowel graft in the diagonal plane in comparison to the coronal plane significantly increased the initial stability of an ankle arthrodesis.
  •  