SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Eriksson LA) srt2:(2005-2009)"

Sökning: WFRF:(Eriksson LA) > (2005-2009)

  • Resultat 1-13 av 13
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Barret, B., et al. (författare)
  • Intercomparisons of trace gases profiles from the Odin/SMR and Aura/MLS limb sounders
  • 2006
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 111:D21
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the intercomparison of O(3), HNO(3), ClO, N(2)O and CO profiles measured by the two spaceborne microwave instruments MLS ( Microwave Limb Sounder) and SMR ( Submillimetre Radiometer) on board the Aura and Odin satellites, respectively. We compared version 1.5 level 2 data from MLS with level 2 data produced by the French data processor version 222 and 225 and by the Swedish data processor version 2.0 for several days in September 2004 and in March 2005. For the five gases studied, an overall good agreement is found between both instruments. Most of the observed discrepancies between SMR and MLS are consistent with results from other intercomparison studies involving MLS or SMR. O(3) profiles retrieved from the SMR 501.8 GHz band are noisier than MLS profiles but mean biases between both instruments do not exceed 10%. SMR HNO(3) profiles are biased low relative to MLS's by similar to 30% above the profile peak. In the lower stratosphere, MLS ClO profiles are biased low by up to 0.3 ppbv relative to coincident SMR profiles, except in the Southern Hemisphere polar vortex in the presence of chlorine activation. N(2)O profiles from both instruments are in very good agreement with mean biases not exceeding 15%. Finally, the intercomparison between SMR and MLS CO profiles has shown a good agreement from the middle stratosphere to the middle mesosphere in spite of strong oscillations in the MLS profiles. In the upper mesosphere, MLS CO concentrations are biased high relative to SMR while negative values in the MLS retrievals are responsible for a negative bias in the tropics around 30 hPa.
  •  
2.
  •  
3.
  • Jégou, F., et al. (författare)
  • Validation of Odin/SMR limb observations of ozone, comparisons with OSIRIS, POAM III, ground-based and balloon-borne intruments
  • 2008
  • Ingår i: Atmospheric Chemistry and Physics. - : Copernicus GmbH. - 1680-7316 .- 1680-7324. ; 8:13, s. 3385-3409
  • Tidskriftsartikel (refereegranskat)abstract
    • The Odin satellite carries two instruments capable of determining stratospheric ozone profiles by limb sounding: the Sub-Millimetre Radiometer (SMR) and the UV-visible spectrograph of the OSIRIS (Optical Spectrograph and InfraRed Imager System) instrument. A large number of ozone profiles measurements were performed during six years from November 2001 to present. This ozone dataset is here used to make quantitative comparisons with satellite measurements in order to assess the quality of the Odin/SMR ozone measurements. In a first step, we compare Swedish SMR retrievals version 2.1, French SMR ozone retrievals version 222 (both from the 501.8 GHz band), and the OSIRIS retrievals version 3.0, with the operational version 4.0 ozone product from POAM III (Polar Ozone Atmospheric Measurement). In a second step, we refine the Odin/SMR validation by comparisons with ground-based instruments and balloon-borne observations. We use observations carried out within the framework of the Network for Detection of Atmospheric Composition Change (NDACC) and balloon flight missions conducted by the Canadian Space Agency (CSA), the Laboratoire de Physique et de Chimie de l\'{}Environnement (LPCE, Orléans, France), and the Service d'Aéronomie (SA, Paris, France). Coincidence criteria were 5° in latitude×10° in longitude, and 5 h in time in Odin/POAM III comparisons, 12 h in Odin/NDACC comparisons, and 72 h in Odin/balloons comparisons. An agreement is found with the POAM III experiment (10–60 km) within −0.3±0.2 ppmv (bias±standard deviation) for SMR (v222, v2.1) and within −0.5±0.2 ppmv for OSIRIS (v3.0). Odin ozone mixing ratio products are systematically slightly lower than the POAM III data and show an ozone maximum lower by 1–5 km in altitude. The comparisons with the NDACC data (10–34 km for ozonesonde, 10–50 km for lidar, 10–60 for microwave instruments) yield a good agreement within −0.15±0.3 ppmv for the SMR data and −0.3±0.3 ppmv for the OSIRIS data. Finally the comparisons with instruments on large balloons (10–31 km) show a good agreement, within −0.7±1 ppmv. The official SMR v2.1 dataset is consistent in all altitude ranges with POAM III, NDACC and large balloon-borne instruments measurements. In the SMR v2.1 data, no different systematic error has been found in the 0–35km range in comparison with the 35–60 km range. The same feature has been highlighted in both hemispheres in SMR v2.1/POAM III intercomparisons, and no latitudinal dependence has been revealed in SMR v2.1/NDACC intercomparisons.
  •  
4.
  • Lamalle, P. U., et al. (författare)
  • Expanding the operating space of ICRF on JET with a view to ITER
  • 2006
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 0029-5515 .- 1741-4326. ; 46:2, s. 391-400
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper reports on ITER-relevant ion cyclotron resonance frequency (ICRF) physics investigated on JET in 2003 and early 2004. Minority heating of helium three in hydrogen plasmas-(He-3)H-was systematically explored by varying the 3 He concentration and the toroidal phasing of the antenna arrays. The best heating performance (a maximum electron temperature of 6.2 keV with 5 MW of ICRF power) was obtained with a preferential wave launch in the direction of the plasma current. A clear experimental demonstration was made of the sharp and reproducible transition to the mode conversion heating regime when the 3 He concentration increased above similar to 2%. In the latter regime the best heating performance (a maximum electron temperature of 8 keV with 5 MW of ICRF power) was achieved with dipole array phasing, i.e. a symmetric antenna power spectrum. Minority heating of deuterium in hydrogen plasmas-(D)H-was also investigated but was found inaccessible because this scenario is too sensitive to impurity ions with Z/A = 1/2 such as C6+, small amounts of which directly lead into the mode conversion regime. Minority heating of up to 3% of tritium in deuterium plasmas was systematically investigated during the JET trace tritium experimental campaign (TTE). This required operating JET at its highest possible magnetic field (3.9 to 4 T) and the ICRF system at its lowest frequency (23 MHz). The interest of this scenario for ICRF heating at these low concentrations and its efficiency at boosting the suprathermal neutron yield were confirmed, and the measured neutron and gammay ray spectra permit interesting comparisons with advanced ICRF code simulations. Investigations of finite Larmor radius effects on the RF-induced high-energy tails during second harmonic (omega = 2 omega(c)) heating of a hydrogen minority in D plasmas clearly demonstrated a strong decrease in the RF diffusion coefficient at proton energies similar to 1 MeV in agreement with theoretical expectations. Fast wave heating and current drive experiments in deuterium plasmas showed effective direct electron heating with dipole phasing of the antennas, but only small changes of the central plasma current density were observed with the directive phasings, in particular at low single pass damping. New investigations of the heating efficiency of ICRF antennas confirmed its strong dependence on the parallel wavenumber spectrum. Advances in topics of a more technological nature are also summarized: ELM studies using fast RF measurements, the successful experimental demonstration of a new ELM-tolerant antenna matching scheme and technical enhancements planned on the JET ICRF system for 2006, they being equally strongly driven by the preparation for ITER.
  •  
5.
  • Lamalle, P.U, et al. (författare)
  • Expanding the operating space of ICRF on JET with a view to ITER
  • 2006
  • Ingår i: Nucl. Fusion. ; 46, s. 391-
  • Tidskriftsartikel (refereegranskat)abstract
    • Mercury (Hg) has been used for millennia in many applications, primarily in artisanal mining and as an electrode in the chlor–alkali industry. It is anthropogenically emitted as a pollutant from coal fired power plants and naturally emitted, primarily from volcanoes. Its unique chemical characteristics enable global atmospheric transport and it is deposited after various processes, ultimately ending up in one of its final sinks, such as incorporated into deep sediment or bioaccumulated, primarily in the marine environment. All forms of Hg have been established as toxic, and there have been no noted biological benefits from the metal.Throughout time, there have been notable incidents of Hg intoxication documented, and the negative health effects have been documented to those chronically or acutely exposed. Today, exposure to Hg is largely diet or occupationally dependent, however, many are exposed to Hg from their amalgam fillings. This paper puts a tentative monetary value on Hg polluted food sources in the Arctic, where local, significant pollution sources are limited, and relates this to costs for strategies avoiding Hg pollution and to remediation costs of contaminated sites in Sweden and Japan. The case studies are compiled to help policy makers and the public to evaluate whether the benefits to the global environment from banning Hg and limiting its initial emission outweigh the benefits from its continued use or lack of control of Hg emissions. The cases we studied are relevant for point pollution sources globally and their remediation costs ranged between 2500 and 1.1 million US$ kg−1 Hg isolated from the biosphere. Therefore, regulations discontinuing mercury uses combined with extensive flue gas cleaning for all power plants and waste incinerators is cost effective.
  •  
6.
  •  
7.
  • Rubio, Carlos A., et al. (författare)
  • Reliability of the reported size of removed colorectal polyps
  • 2006
  • Ingår i: Anticancer Research. - 0250-7005 .- 1791-7530. ; 26:6C, s. 4895-4899
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The size of colorectal polyps is important in the clinical management of these lesions. Aim: To audit the accuracy in calculating the size of polyps by various specialists. Materials and Methods: Eighteen pathologists and four surgeons measured, with a conventional millimetre ruler, the largest diameter of 12 polyp phantoms. The results of two independent measurements (two weeks apart) were compared with the gold standard-size assessed at The Royal Institute of Technology, Sweden. Results: Thirty-one percent (83/264-trial 1) and 33% (88/264-trial 2) of the measurements underestimated or overestimated the gold standard size by > 1 mm. Of the 22 experienced participants, 95% (21/22-trial 1) and 91% (20/22-trial 2) misjudged by > 1 mm the size of one or more polyps. Values given by 13 participants (4.9%) in trial I and by 15 participants (5.7%) in trial 2, differed by ! 4 mm from the gold standard size. In addition, a big difference between the highest and the lowest values was recorded in some polyps (up to 11.4 mm). Those disparate values were regarded as a human error in reading the scale on the ruler. Conclusion: Using a conventional ruler (the tool of pathologists worldwide) unacceptably high intra-observer and inter-observer variations in assessing the size of polyp-phantoms was found. The volume and the shape of devices, as well as human error in reading the scale of the ruler were confounding factors in size assessment. In praxis, the size is crucial in the management of colorectal polyps. Considering the clinical implications of the results obtained, the possibility of developing a method that will allow assessment of the true size of removed clinical polyps is being explored.
  •  
8.
  •  
9.
  •  
10.
  •  
11.
  • Urban, Joachim, 1964, et al. (författare)
  • Odin/SMR Limb Observations of Stratospheric Trace Gases: Level 2 Processing of ClO, N2O, O3, and HNO3
  • 2005
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 110:D14, s. 1-20
  • Tidskriftsartikel (refereegranskat)abstract
    • The Sub-Millimetre Radiometer (SMR) on board the Odin satellite, launched on 20 February 2001, observes key species with respect to stratospheric chemistry and dynamics such as O-3, ClO, N2O, and HNO3 using two bands centered at 501.8 and 544.6 GHz. We present the adopted methodology for level 2 processing and the achieved in-orbit measurement capabilities of the SMR radiometer for these species in terms of altitude range, altitude resolution, and measurement precision. The characteristics of the relevant level 2 data versions, namely version 1.2 of the operational processor as well as versions 222 and 223 of the reference code, are discussed and differences are evaluated. An analysis of systematic retrieval errors, resulting from spectroscopic and instrumental uncertainties, is also presented.
  •  
12.
  • Urban, Joachim, 1964, et al. (författare)
  • Odin/SMR limb observations of stratospheric trace gases: Validation of N2O
  • 2005
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 110:9, s. D09301-20
  • Tidskriftsartikel (refereegranskat)abstract
    • The Sub-Millimetre Radiometer (Odin/SMR) on board the Odin satellite, launched on 20 February 2001, performs regular measurements of the global distribution of stratospheric nitrous oxide (N2O) using spectral observations of the J = 20→ 19 rotational transition centered at 502.296 GHz. We present a quality assessment for the retrieved N2O profiles (level 2 product) by comparison with independent balloonborne and aircraftborne validation measurements as well as by cross-comparing with preliminary results from other satellite instruments. An agreement with the airborne validation experiments within 28 ppbv in terms of the root mean square (RMS) deviation is found for all SMR data versions (v222, v223, and v1.2) under investigation. More precisely, the agreement is within 19 ppbv for N2O volume mixing ratios (VMR) lower than 200 ppbv and within 10% for mixing ratios larger than 150 ppbv. Given the uncertainties due to atmospheric variability inherent to such comparisons, these values should be interpreted as upper limits for the systematic error of the Odin/SMR N2O measurements. Odin/SMR N2O mixing ratios are systematically slightly higher than nonvalidated data obtained from the Improved Limb Atmospheric Spectrometer-II (ILAS-II) on board the Advanced Earth Observing Satellite-II (ADEOS-II). Root mean square deviations are generally within 23 ppbv (or 20% for VMR-N2O > 100 ppbv) for versions 222 and 223. The comparison with data obtained from the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on the Envisat satellite yields a good agreement within 9-17 ppbv (or 10% for VMR-N2O > 100 ppbv) for the same data versions. Odin/SMR version 1.2 data show somewhat larger RMS deviations and a higher positive bias.
  •  
13.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-13 av 13

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy