SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Fredriksson Ingemar 1980 ) srt2:(2010-2014)"

Sökning: WFRF:(Fredriksson Ingemar 1980 ) > (2010-2014)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Fredriksson, Ingemar, 1980-, et al. (författare)
  • Inverse Monte Carlo in a multilayered tissue model: merging diffuse reflectance spectroscopy and laser Doppler flowmetry
  • 2013
  • Ingår i: Journal of Biomedical Optics. - Bellingham, WA, United States : SPIE - International Society for Optical Engineering. - 1083-3668 .- 1560-2281. ; 18:12, s. 127004-1-127004-14
  • Tidskriftsartikel (refereegranskat)abstract
    • The tissue fraction of red blood cells (RBCs) and their oxygenation and speed-resolved perfusion areestimated in absolute units by combining diffuse reflectance spectroscopy (DRS) and laser Doppler flowmetry(LDF). The DRS spectra (450 to 850 nm) are assessed at two source–detector separations (0.4 and 1.2 mm), allowingfor a relative calibration routine, whereas LDF spectra are assessed at 1.2mmin the same fiber-optic probe. Data areanalyzed using nonlinear optimization in an inverse Monte Carlo technique by applying an adaptive multilayeredtissue model based on geometrical, scattering, and absorbing properties, as well as RBC flow-speed information.Simulations of 250 tissue-like models including up to 2000 individual blood vessels were used to evaluatethe method. The absolute root mean square (RMS) deviation between estimated and true oxygenation was 4.1percentage units, whereas the relative RMS deviations for the RBC tissue fraction and perfusion were 19% and23%, respectively. Examples of in vivo measurements on forearm and foot during common provocations arepresented. The method offers several advantages such as simultaneous quantification of RBC tissue fractionand oxygenation and perfusion from the same, predictable, sampling volume. The perfusion estimate is speedresolved, absolute (% RBC × mm∕s), and more accurate due to the combination with DRS.
  •  
2.
  • Fredriksson, Ingemar, 1980-, et al. (författare)
  • Laser doppler flowmetry
  • 2012
  • Ingår i: Microcirculation imaging. - Weinheim : Wiley-VCH Verlagsgesellschaft. - 3527328947 - 9783527328949 - 9783527651238 ; , s. 67-86
  • Bokkapitel (övrigt vetenskapligt/konstnärligt)abstract
    • Adopting a multidisciplinary approach with input from physicists, researchers and medical professionals, this is the first book to introduce many different technical approaches for the visualization of microcirculation, including laser Doppler and laser speckle, optical coherence tomography and photo-acoustic tomography. It covers everything from basic research to medical applications, providing the technical details while also outlining the respective strengths and weaknesses of each imaging technique. Edited by an international team of top experts, this is the ultimate handbook for every clinician and researcher relying on microcirculation imaging.
  •  
3.
  • Fredriksson, Ingemar, 1980-, et al. (författare)
  • Model-based quantitative laser Doppler flowmetry in skin
  • 2010
  • Ingår i: Journal of Biomedical Optics. - : Society of Photo-optical Instrumentation Engineers. - 1083-3668 .- 1560-2281. ; 15:5
  • Tidskriftsartikel (refereegranskat)abstract
    • Laser Doppler Flowmetry (LDF) can be used for assessing the microcirculatory perfusion. However, conventional LDF (cLDF) gives only a relative perfusion estimate in an unknown measurement volume. To overcome these limitations a model-based analysis method for quantitative LDF (qLDF) is proposed. The method uses an inverse Monte Carlo technique with an adaptive three layer skin model. By analyzing the optimal model where measured and simulated LDF spectra using two different source-detector separations match, the absolute microcirculatory perfusion for a specified velocity region in a predefined volume is determined. The robustness of the qLDF method and how much it is affected by physiologically relevant variations in optical properties were evaluated using additional Monte Carlo simulations. When comparing qLDF to cLDF, a much smaller deviation from the true perfusion was attained. For physiologically relevant variations in the optical properties of static tissue and blood absorption, qLDF displayed errors <12%. Variations in the scattering properties of blood displayed larger errors (<58%). Evaluations on inhomogeneous models containing small blood vessels, hair and sweat glands displayed errors <5%. For extremely inhomogeneous models containing larger blood vessels, the error increased substantially, but this was detected by analyzing the qLDF model residual. The qLDF algorithm was applied to an in vivo local heat provocation. The perfusion increase was higher with qLDF than cLDF, due to non-linear effects in the latter. The qLDF showed that the perfusion increase was due to an increased amount of blood cells with a velocity > 1 mm/s.
  •  
4.
  • Strömberg, Tomas, 1966-, et al. (författare)
  • Experimental results using a three-layer skin model for diffuse reflectance spectroscopy
  • 2013
  • Ingår i: Optical Tomography and Spectroscopy of Tissue X. - : SPIE - International Society for Optical Engineering. - 9780819493477 ; , s. 857834-1-857834-8
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • We have previously presented an inverse Monte Carlo algorithm based on a three-layer semi-infinite skin model for analyzing diffuse reflectance spectroscopy (DRS) data. The algorithm includes pre-simulated Monte Carlo data for a range of physiologically relevant epidermal thicknesses and tissue scattering levels. The simulated photon pathlength distributions in each layer are stored and the absorption effect from tissue chromophores added in the post-processing. Recorded DRS spectra at source-detector distances of 0.4 and 1.2 mm were calibrated for the relative intensity between the two distances and matched to simulated spectra in a non-linear optimization algorithm. This study evaluates the DRS spectral fitting accuracy and presents data on the main output parameters; the tissue fraction of red blood cells and local oxygenation (SO2). As a reference, the microcirculatory perfusion (Perf) was measured simultaneously in the same probe using laser Doppler Flowmetry. Data were recorded on the volar forearm of three healthy subjects in a protocol involving a 5 min systolic occlusion. The DRS spectra were modeled with an rms-error < 2%. In two subjects, SO2 decreased during occlusion to <10%, and increased to above baseline after hyperemia, while Perf increased >7 times compared to baseline. In the third subject the SO2 decreased less during occlusion and increased to baseline values at hyperemia with only a 2-fold increase in Perf. The observed difference could be due to different microvascular beds being probed. It is concluded that integrating DRS and LDF enables new possibilities to deduce microcirculation status.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy