SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Funehag Johan 1975) srt2:(2003-2004)"

Sökning: WFRF:(Funehag Johan 1975) > (2003-2004)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Funehag, Johan, 1975 (författare)
  • Grouting and Analyses of a Fracture in Äspö HRL, Characterisation, grouting and verification of grouting results for silica sol
  • 2004
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • This report is part of the project Non-cementitious low-pH injection grout for smaller fractures that is a sub-project under the main project Injection grout for deep repositories. The project is financed by SKB (Sweden), Posiva (Finland) and NUMO (Japan). The sub-project objective is to find a grout that can be used to grout fractures with a hydraulic aperture less than 100 μm and that fulfills environmental and long-term safety demands.This report describes a field test conducted during spring 2004 in a pillar located in the main tunnel at Äspö HRL at a depth of around 100 m below the surface. Previous studies (Fransson, 2001) show that the fracture of interest is found in a section 2.0-2.5 m in a borehole drilled parallel to the main tunnel. The transmissivity is around 5x10-8 m2/s corresponding to a hydraulic aperture of approximately 40 50 μm. The fracture has earlier been grouted with cement which resulted in a penetration length of around 0.1 m around the grouted borehole (Eriksson, 2002).The fracture was grouted with a silica sol, produced by Eka Chemicals, Bohus under the name Eka® Gel EXP36. It consists of extremely small amorphous silica particles suspended in water. The accelerator used was a salt solution, CaCl2 (2,9%). The pH is around 10. The grout was also mixed with optical brightener to make it possible to see the grout using UV-light. The grouting design was determined using the hydraulic aperture analysed by Fransson, 2001. Three methods were used to determine the penetration length and sealing efficiency; namely detection of grout in 6 cores using UV-light, analysing part of the grouted fracture in microscope and using hydraulic tests. The results show that five of totally six cores had traces of silica sol, which would indicate a penetration length of at least 1 m in the fracture. The microscopy analyses verify that silica sol were apparent in the fracture but not completely filled. The achieved penetration length of 1 m was compared with 2-D mathematical model. The results show that the model underestimates the penetration length with 0.25 to 0.35 m. The hydraulic tests result in a sealing efficiency of the silica sol grouting in the affected rock mass of 70%.
  •  
2.
  •  
3.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4
Typ av publikation
rapport (2)
tidskriftsartikel (2)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (2)
refereegranskat (2)
Författare/redaktör
Funehag, Johan, 1975 (4)
Axelsson, Magnus, 19 ... (1)
Gustafson, Gunnar, 1 ... (1)
Lärosäte
Chalmers tekniska högskola (4)
Språk
Engelska (3)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (4)
Teknik (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy