SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Gaeta Araujo H) srt2:(2021)"

Sökning: WFRF:(Gaeta Araujo H) > (2021)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Gaeta-Araujo, H, et al. (författare)
  • Two decades of research on CBCT imaging in DMFR - an appraisal of scientific evidence
  • 2021
  • Ingår i: Dento maxillo facial radiology. - : British Institute of Radiology. - 0250-832X. ; 50:4, s. 20200367-
  • Tidskriftsartikel (refereegranskat)abstract
    • This article aims to appraise how scientific evidence related to CBCT has changed over the years, based on levels of evidence and diagnostic efficacy. Methods: A general search strategy was used in different databases (Pubmed, Embase, and Web of Science) to identify systematic reviews (SRs) on CBCT until November of 2020. The SRs included were divided according to different specialties of dentistry. A critical review of the articles was made, describing the level of evidence and efficacy. Results: In total, 75 articles were selected. There was an increase in the number of SRs on CBCT from 2014 onwards, as 83% of the SRs on this topic were published after 2013, and 72% between 2016 and to date. Twenty SRs (27%) performed meta-analysis. Only 28% of the SRs provided a detailed description of CBCT protocols. According to SR evidence, almost all specialties of dentistry have advanced concomitantly with the introduction of CBCT. The majority of SRs were related to clinical applications (level 2 of efficacy), followed by technical parameters (level 1 of efficacy). Only some CBCT models were mentioned in the SRs selected. Conclusion: Over the course of 20 years, SRs related to CBCT applications for a broad range of dental specialties have been published, with the vast majority of studies at levels 1 and 2 of diagnostic efficacy. Not all CBCT models available on the market have been scientifically validated. At all times, one should remain cautious as such not to simply extrapolate in vitro results to the clinical setting. Also, considering the wide variety of CBCT devices and protocols, reported results should not be overstated or generalized, as outcomes often refer to specific CBCT devices and protocols.
  •  
4.
  •  
5.
  • Rodrigues, CT, et al. (författare)
  • Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars
  • 2021
  • Ingår i: Dento maxillo facial radiology. - : British Institute of Radiology. - 0250-832X. ; 50:5, s. 20200503-
  • Tidskriftsartikel (refereegranskat)abstract
    • To evaluate the influence of artefacts in cone beam CT (CBCT) images of filled root canals in isthmus-containing molars.Methods:10 teeth presenting canals with an isthmus were instrumented and filled with a thermoplasticised obturation technique. The teeth were scanned using a micro-CT device and two CBCT devices: 3D Accuitomo 170 (ACC) and NewTom VGi evo (NT), with different acquisition protocols: larger and smaller voxel size. Three examiners assessed the CBCT images for: (1) detection of filling voids; (2) assessment of under- or overestimation of the filling material and (3) resemblance of CBCT images to the reference standard. Analyses of Task 1 yielded accuracy, sensitivity and specificity for detection of filling voids. For tasks 2 and 3, statistical analysis was performed using Wilcoxon test. The level of significance was set at p < .05.Results:For Task 1, ACC showed higher sensitivity, whereas NT presented higher specificity. No significant difference was found between the protocols in ACC, however, for NT, differences between protocols were significant for all diagnostic values. In Task 2, visualisation of the filling was overestimated for NT, while for ACC, underestimation was observed. For Task 3, images with smaller voxel size were more similar to the reference image, for both CBCT devices.Conclusions:Different artefacts compromise the detection of filling voids on CBCT images of canals in mandibular molars with isthmus. ACC and NT present rather similar diagnostic accuracy, even though artefact expression remains device-specific.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy