SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Garrido J.) srt2:(2005-2009)"

Sökning: WFRF:(Garrido J.) > (2005-2009)

  • Resultat 1-16 av 16
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Schael, S, et al. (författare)
  • Precision electroweak measurements on the Z resonance
  • 2006
  • Ingår i: Physics Reports. - : Elsevier BV. - 0370-1573 .- 1873-6270. ; 427:5-6, s. 257-454
  • Forskningsöversikt (refereegranskat)abstract
    • We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLID experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, m(Z) and Gamma(Z), and its couplings to fermions, for example the p parameter and the effective electroweak mixing angle for leptons, are precisely measured: m(Z) = 91.1875 +/- 0.0021 GeV, Gamma(Z) = 2.4952 +/- 0.0023 GeV, rho(l) = 1.0050 +/- 0.0010, sin(2)theta(eff)(lept) = 0.23153 +/- 0.00016. The number of light neutrino species is determined to be 2.9840 +/- 0.0082, in agreement with the three observed generations of fundamental fermions. The results are compared to the predictions of the Standard Model (SM). At the Z-pole, electroweak radiative corrections beyond the running of the QED and QCD coupling constants are observed with a significance of five standard deviations, and in agreement with the Standard Model. Of the many Z-pole measurements, the forward-backward asymmetry in b-quark production shows the largest difference with respect to its SM expectation, at the level of 2.8 standard deviations. Through radiative corrections evaluated in the framework of the Standard Model, the Z-pole data are also used to predict the mass of the top quark, m(t) = 173(+10)(+13) GeV, and the mass of the W boson, m(W) = 80.363 +/- 0.032 GeV. These indirect constraints are compared to the direct measurements, providing a stringent test of the SM. Using in addition the direct measurements of m(t) and m(W), the mass of the as yet unobserved SM Higgs boson is predicted with a relative uncertainty of about 50% and found to be less than 285 GeV at 95% confidence level. (c) 2006 Elsevier B.V. All rights reserved.
  •  
2.
  • Abate, E., et al. (författare)
  • Combined performance tests before installation of the ATLAS Semiconductor and Transition Radiation Tracking Detectors
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS (A Toroidal LHC ApparatuS) Inner Detector provides charged particle tracking in the centre of the ATLAS experiment at the Large Hadron Collider (LHC). The Inner Detector consists of three subdetectors: the Pixel Detector, the Semiconductor Tracker (SCT), and the Transition Radiation Tracker (TRT). This paper summarizes the tests that were carried out at the final stage of SCT+TRT integration prior to their installation in ATLAS. The combined operation and performance of the SCT and TRT barrel and endcap detectors was investigated through a series of noise tests, and by recording the tracks of cosmic rays. This was a crucial test of hardware and software of the combined tracker detector systems. The results of noise and cross-talk tests on the SCT and TRT in their final assembled configuration, using final readout and supply hardware and software, are reported. The reconstruction and analysis of the recorded cosmic tracks allowed testing of the offline analysis chain and verification of basic tracker performance parameters, such as efficiency and spatial resolution, in combined operation before installation.
  •  
3.
  •  
4.
  • Abat, E., et al. (författare)
  • Study of the response of the ATLAS central calorimeter to pions of energies from 3 to 9 GeV
  • 2009
  • Ingår i: Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment. - : Elsevier BV. - 0167-5087 .- 0168-9002 .- 1872-9576. ; 607:2, s. 372-386
  • Tidskriftsartikel (refereegranskat)abstract
    • A fully instrumented slice of the ATLAS central detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. in this paper, the response of the central calorimeters to pions with energies in the range between 3 and 9 GeV is presented. The linearity and the resolution of the combined calorimetry (electromagnetic and hadronic calorimeters) was measured and compared to the prediction of a detector simulation program using the toolkit Geant 4. (C) 2009 Elsevier B.V. All rights reserved.
  •  
5.
  • Abat, E., et al. (författare)
  • The ATLAS TRT end-cap detectors
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS TRT end-cap is a tracking drift chamber using 245,760 individual tubular drift tubes. It is a part of the TRT tracker which consist of the barrel and two end-caps. The TRT end-caps cover the forward and backward pseudo-rapidity region 1.0 < vertical bar eta vertical bar < 2.0, while the TRT barrel central eta region vertical bar eta vertical bar < 1.0. The TRT system provides a combination of continuous tracking with many measurements in individual drift tubes ( or straws) and of electron identification based on transition radiation from fibers or foils interleaved between the straws themselves. Along with other two sub-systems, namely the Pixel detector and Semi Conductor Tracker (SCT), the TRT constitutes the ATLAS Inner Detector. This paper describes the recently completed and installed TRT end-cap detectors, their design, assembly, integration and the acceptance tests applied during the construction.
  •  
6.
  • Abat, E., et al. (författare)
  • The ATLAS Transition Radiation Tracker (TRT) proportional drift tube: design and performance
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:2
  • Tidskriftsartikel (refereegranskat)abstract
    • A straw proportional counter is the basic element of the ATLAS Transition Radiation Tracker (TRT). Its detailed properties as well as the main properties of a few TRT operating gas mixtures are described. Particular attention is paid to straw tube performance in high radiation conditions and to its operational stability.
  •  
7.
  • Abat, E., et al. (författare)
  • The ATLAS TRT barrel detector
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS TRT barrel is a tracking drift chamber using 52,544 individual tubular drift tubes. It is one part of the ATLAS Inner Detector, which consists of three sub-systems: the pixel detector spanning the radius range 4 to 20 cm, the semiconductor tracker (SCT) from 30 to 52 cm, and the transition radiation tracker ( TRT) from 56 to 108 cm. The TRT barrel covers the central pseudo-rapidity region |eta| < 1, while the TRT endcaps cover the forward and backward eta regions. These TRT systems provide a combination of continuous tracking with many measurements in individual drift tubes ( or straws) and of electron identification based on transition radiation from fibers or foils interleaved between the straws themselves. This paper describes the recently-completed construction of the TRT Barrel detector, including the quality control procedures used in the fabrication of the detector.
  •  
8.
  • Abat, E., et al. (författare)
  • The ATLAS TRT electronics
  • 2008
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 3:6
  • Tidskriftsartikel (refereegranskat)abstract
    • The ATLAS inner detector consists of three sub-systems: the pixel detector spanning the radius range 4cm-20cm, the semiconductor tracker at radii from 30 to 52 cm, and the transition radiation tracker (TRT), tracking from 56 to 107 cm. The TRT provides a combination of continuous tracking with many projective measurements based on individual drift tubes (or straws) and of electron identification based on transition radiation from fibres or foils interleaved between the straws themselves. This paper describes the on and off detector electronics for the TRT as well as the TRT portion of the data acquisition (DAQ) system.
  •  
9.
  • Galluzzi, L, et al. (författare)
  • Guidelines for the use and interpretation of assays for monitoring cell death in higher eukaryotes.
  • 2009
  • Ingår i: Cell death and differentiation. - : Springer Science and Business Media LLC. - 1476-5403 .- 1350-9047. ; 16:8, s. 1093-107
  • Forskningsöversikt (refereegranskat)abstract
    • Cell death is essential for a plethora of physiological processes, and its deregulation characterizes numerous human diseases. Thus, the in-depth investigation of cell death and its mechanisms constitutes a formidable challenge for fundamental and applied biomedical research, and has tremendous implications for the development of novel therapeutic strategies. It is, therefore, of utmost importance to standardize the experimental procedures that identify dying and dead cells in cell cultures and/or in tissues, from model organisms and/or humans, in healthy and/or pathological scenarios. Thus far, dozens of methods have been proposed to quantify cell death-related parameters. However, no guidelines exist regarding their use and interpretation, and nobody has thoroughly annotated the experimental settings for which each of these techniques is most appropriate. Here, we provide a nonexhaustive comparison of methods to detect cell death with apoptotic or nonapoptotic morphologies, their advantages and pitfalls. These guidelines are intended for investigators who study cell death, as well as for reviewers who need to constructively critique scientific reports that deal with cellular demise. Given the difficulties in determining the exact number of cells that have passed the point-of-no-return of the signaling cascades leading to cell death, we emphasize the importance of performing multiple, methodologically unrelated assays to quantify dying and dead cells.
  •  
10.
  • Genuneit, J., et al. (författare)
  • A multi-centre study of candidate genes for wheeze and allergy : the International Study of Asthma and Allergies in Childhood Phase 2
  • 2009
  • Ingår i: Clinical and Experimental Allergy. - : John Wiley & Sons. - 0954-7894 .- 1365-2222. ; 39:12, s. 1875-1888
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Common polymorphisms have been identified in genes suspected to play a role in asthma. We investigated their associations with wheeze and allergy in a case-control sample from Phase 2 of the International Study of Asthma and Allergies in Childhood.METHODS: We compared 1105 wheezing and 3137 non-wheezing children aged 8-12 years from 17 study centres in 13 countries. Genotyping of 55 candidate single nucleotide polymorphisms (SNPs) in 14 genes was performed using the Sequenom System. Logistic regression models were fitted separately for each centre and each SNP. A combined per allele odds ratio and measures of heterogeneity between centres were derived by random effects meta-analysis.RESULTS: Significant associations with wheeze in the past year were detected in only four genes (IL4R, TLR4, MS4A2, TLR9, P<0.05), with per allele odds ratios generally <1.3. Variants in IL4R and TLR4 were also related to allergen-specific IgE, while polymorphisms in FCER1B (MS4A2) and TLR9 were not. There were also highly significant associations (P<0.001) between SPINK5 variants and visible eczema (but not IgE levels) and between IL13 variants and total IgE. Heterogeneity of effects across centres was rare, despite differences in allele frequencies.CONCLUSIONS: Despite the biological plausibility of IgE-related mechanisms in asthma, very few of the tested candidates showed evidence of association with both wheeze and increased IgE levels. We were unable to confirm associations of the positional candidates DPP10 and PHF11 with wheeze, although our study had ample power to detect the expected associations of IL13 variants with IgE and SPINK5 variants with eczema.
  •  
11.
  • Astermark, Jan, et al. (författare)
  • Current European practice in immune tolerance induction therapy in patients with haemophilia and inhibitors.
  • 2006
  • Ingår i: Haemophilia. - : Wiley. - 1351-8216 .- 1365-2516. ; 12:4, s. 363-371
  • Tidskriftsartikel (refereegranskat)abstract
    • The management of patients with inhibitors is an important challenge in haemophilia care. The lack of randomized controlled trials means that clinical decisions are generally based on subjective opinions, and purchasers' attention is likely to focus on the costs of treatment. In order to assess the current management of inhibitor patients and use of immune tolerance induction therapy (ITI) in Europe, we performed a survey within a European network of 21 comprehensive care centres from 14 countries (the European Haemophilia Therapy Standardisation Board). The survey identified a total of 381 patients with inhibitors attending the centres, 211 (55.4%) of whom had never been exposed to ITI. Between 1998 and 2003, the centres performed 233 procedures and 114 (48.9%) were successful. The survey demonstrated that dosing, which is the time to start and stop the ITI, the type of concentrate to use and the definition of success varied among the centres. Well-designed trials are warranted to guide decision-making, but in the absence of these studies we have developed consensus guidance for the management of inhibitor patients based on current clinical practice, as identified by the survey, and review of the literature.
  •  
12.
  • Astermark, Jan, et al. (författare)
  • Current use of by-passing agents in Europe in the management of acute bleeds in patients with haemophilia and inhibitors.
  • 2007
  • Ingår i: Haemophilia. - : Wiley. - 1351-8216 .- 1365-2516. ; 13:1, s. 38-45
  • Tidskriftsartikel (refereegranskat)abstract
    • The ultimate goal of treatment for patients with inhibitory antibodies should be to permanently eradicate the inhibitor by immune tolerance induction therapy (ITI). However, ITI procedures fail in a substantial number of patients and in many countries ITI is not even offered owing to its high cost. How patients with inhibitors are managed in different European countries is evaluated with a special focus on the use of by-passing agents, i.e. recombinant FVIIa (rFVIIa) and activated prothrombin complex concentrates (aPCC), as well as the type of monitoring performed. Investigators from 22 large haemophilia centres participating within the network of the European Haemophilia Therapy Standardisation Board (EHTSB) were asked to complete a questionnaire. rFVIIa was routinely used in all centres for both children and adults at dosages ranging from 90 to 250 mu g kg(-1) at an interval of 2-4 h. aPCC was used in 85% of the centres in adults and in 25% of the centres in children with haemophilia A at dosages of 50-100 IU kg(-1) every 6-12 h. The corresponding figures for children and adults with haemophilia B were 40% and 15% of the centres, respectively. Higher dosages of both agents were considered in the case of life-threatening bleeds. General recommendations were developed, based on the information provided by the survey. The results clearly indicate the need for well-designed comparative studies to optimize the use of by-passing agents.
  •  
13.
  •  
14.
  • Garrido, Mario, 1981-, et al. (författare)
  • Efficient Memoryless Cordic for FFT Computation
  • 2007
  • Ingår i: Efficient Memoryless Cordic for FFT Computation. - : IEEE. - 1424407281 - 1424407273 ; , s. II-113-II-116
  • Konferensbidrag (refereegranskat)abstract
    • A new memoryless CORDIC algorithm for the FFT computation is proposed in this paper. This approach calculates the direction of the micro-rotations from the control counter of the FFT, so the area of the rotator hardly depends on the number of rotations, which is particularly suitable for the computation of FFTs of a high number of points. Moreover, the new CORDIC presents other advantages such as the simplification of the basic CORDIC processor used to calculate the micro-rotations, or an easy way to compensate the intrinsic gain of the CORDIC algorithm. Additionally, the VLSI implementation of the algorithm is a pipeline architecture with high performance in terms of speed, throughput and latency.
  •  
15.
  •  
16.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-16 av 16

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy