SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Högberg Charlotta) srt2:(2020-2022)"

Sökning: WFRF:(Högberg Charlotta) > (2020-2022)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lossow, Stefan, et al. (författare)
  • A reassessment of the discrepancies in the annual variation of delta D-H2O in the tropical lower stratosphere between the MIPAS and ACE-FTS satellite data sets
  • 2020
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 13:1, s. 287-308
  • Tidskriftsartikel (refereegranskat)abstract
    • The annual variation of delta D in the tropical lower stratosphere is a critical indicator for the relative importance of different processes contributing to the transport of water vapour through the cold tropical tropopause region into the stratosphere. Distinct observational discrepancies of the delta D annual variation were visible in the works of Steinwagner et al. (2010) and Randel et al. (2012). Steinwagner et al. (2010) analysed MIPAS (Michelson Interferometer for Passive Atmospheric Sounding) observations retrieved with the IMK/IAA (Institut fur Meteorologie und Klimaforschung in Karlsruhe, Germany, in collaboration with the Instituto de Astrofisica de Andalucia in Granada, Spain) processor, while Randel et al. (2012) focused on ACE-FTS (Atmospheric Chemistry Experiment Fourier Transform Spectrometer) observations. Here we reassess the discrepancies based on newer MIPAS (IMK/IAA) and ACE-FTS data sets, also showing for completeness results from SMR (Sub-Millimetre Radiometer) observations and a ECHAM/MESSy (European Centre for Medium-Range Weather Forecasts Hamburg and Modular Earth Sub-model System) Atmospheric Chemistry (EMAC) simulation (Eichinger et al., 2015b). Similar to the old analyses, the MIPAS data set yields a pronounced annual variation (maximum about 75 parts per thousand), while that derived from the ACE-FTS data set is rather weak (maximum about 25 parts per thousand). While all data sets exhibit the phase progression typical for the tape recorder, the annual maximum in the ACE-FTS data set precedes that in the MIPAS data set by 2 to 3 months. We critically consider several possible reasons for the observed discrepancies, focusing primarily on the MIPAS data set. We show that the delta D annual variation in the MIPAS data up to an altitude of 40 hPa is substantially impacted by a start altitude effect, i.e. dependency between the lowermost altitude where MIPAS retrievals are possible and retrieved data at higher altitudes. In itself this effect does not explain the differences with the ACE-FTS data. In addition, there is a mismatch in the vertical resolution of the MIPAS HDO and H2O data (being consistently better for HDO), which actually results in an artificial tape-recorder-like signal in delta D. Considering these MIPAS characteristics largely removes any discrepancies between the MIPAS and ACE-FTS data sets and shows that the MIPAS data are consistent with a delta D tape recorder signal with an amplitude of about 25 parts per thousand in the lowermost stratosphere.
  •  
2.
  • Lossow, Stefan, 1977, et al. (författare)
  • A reassessment of the discrepancies in the annual variation of δD-H2O in the tropical lower stratosphere between the MIPAS and ACE-FTS satellite data sets
  • 2020
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 13:1, s. 287-308
  • Tidskriftsartikel (refereegranskat)abstract
    • The annual variation of δD in the tropical lower stratosphere is a critical indicator for the relative importance of different processes contributing to the transport of water vapour through the cold tropical tropopause region into the stratosphere. Distinct observational discrepancies of the δD annual variation were visible in the works of Steinwagner et al. (2010) and Randel et al. (2012). Steinwagner et al. (2010) analysed MIPAS (Michelson Interferometer for Passive Atmospheric Sounding) observations retrieved with the IMK/IAA (Institut für Meteorologie und Klimaforschung in Karlsruhe, Germany, in collaboration with the Instituto de Astrofísica de Andalucía in Granada, Spain) processor, while Randel et al. (2012) focused on ACE-FTS (Atmospheric Chemistry Experiment Fourier Transform Spectrometer) observations. Here we reassess the discrepancies based on newer MIPAS (IMK/IAA) and ACE-FTS data sets, also showing for completeness results from SMR (Sub-Millimetre Radiometer) observations and a ECHAM/MESSy (European Centre for Medium-Range Weather Forecasts Hamburg and Modular Earth Submodel System) Atmospheric Chemistry (EMAC) simulation (Eichinger et al., 2015b). Similar to the old analyses, the MIPAS data set yields a pronounced annual variation (maximum about 75 ‰), while that derived from the ACE-FTS data set is rather weak (maximum about 25 ‰). While all data sets exhibit the phase progression typical for the tape recorder, the annual maximum in the ACE-FTS data set precedes that in the MIPAS data set by 2 to 3 months. We critically consider several possible reasons for the observed discrepancies, focusing primarily on the MIPAS data set. We show that the δD annual variation in the MIPAS data up to an altitude of 40 hPa is substantially impacted by a “start altitude effect”, i.e. dependency between the lowermost altitude where MIPAS retrievals are possible and retrieved data at higher altitudes. In itself this effect does not explain the differences with the ACE-FTS data. In addition, there is a mismatch in the vertical resolution of the MIPAS HDO and H2O data (being consistently better for HDO), which actually results in an artificial tape-recorder-like signal in δD. Considering these MIPAS characteristics largely removes any discrepancies between the MIPAS and ACE-FTS data sets and shows that the MIPAS data are consistent with a δD tape recorder signal with an amplitude of about 25 ‰ in the lowermost stratosphere.
  •  
3.
  • Sandström, Olof, et al. (författare)
  • Five-year follow-up of new cases after a coeliac disease mass screening
  • 2022
  • Ingår i: Archives of Disease in Childhood. - : BMJ Publishing Group Ltd. - 0003-9888 .- 1468-2044. ; 107:6, s. 596-600
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: We previously performed a population-based mass screening of coeliac disease in children aged 12 years in two birth cohorts resulting in 296 seropositive children, of whom 242 were diagnosed with coeliac disease after duodenal biopsies. In this follow-up study, we wanted to identify new cases in the screening population that tested negative-either converting from potential coeliac disease (seropositive but normal duodenal mucosa) or converting from seronegative at screening to diagnosed coeliac disease.METHODS: All seropositive children were invited to a follow-up appointment 5 years after the screening with renewed serological testing and recommended endoscopic investigation if seropositive. Seronegative children in the screening study (n=12 353) were linked to the National Swedish Childhood Coeliac Disease Register to find cases diagnosed in healthcare during the same period.RESULTS: In total, 230 (77%) came to the follow-up appointment, including 34 of 39 with potential coeliac disease. Of these, 11 (32%) had converted to coeliac disease. One new case was found in the National Swedish Childhood Coeliac Disease Register who received the diagnosis through routine screening in children with type 1 diabetes.CONCLUSIONS: There is a high risk of conversion to coeliac disease among those with potential disease. However, a negative screening test was associated with a very low risk for a clinical diagnosis within a follow-up period of 5 years.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy