SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Henrichsen Svein) srt2:(2015-2019)"

Sökning: WFRF:(Henrichsen Svein) > (2015-2019)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kritikos, Vicky, et al. (författare)
  • A multinational observational study identifying primary care patients at risk of overestimation of asthma control
  • 2019
  • Ingår i: npj Primary Care Respiratory Medicine. - : NATURE PUBLISHING GROUP. - 2055-1010. ; 29
  • Tidskriftsartikel (refereegranskat)abstract
    • Factors related to the discrepancy between patient-perceived and actual disease control remain unclear. Identifying patients at risk of overestimation of asthma control remains elusive. This study aimed to (i) investigate the relationship between patient-reported and actual level of asthma control (ii), compare the characteristics between patients who believe their asthma is well controlled that accurately report 'well-controlled' asthma with those that do not, and (iii) identify factors associated with inaccurately reported 'well-controlled' asthma. A historical, multinational, cross-sectional study using data from the iHARP (initiative Helping Asthma in Real-life Patients) review service for adults with asthma prescribed fixed-dose combination therapy. Data from 4274 patients were analysed. A major discrepancy between patient-reported and Global Initiative for Asthma defined asthma control was detected; 71.1% of patients who reported 'well-controlled' asthma were inaccurate in their perception despite receiving regular maintenance therapy. Significant differences were noted in age, gender, body mass index, education level, medication use, side effects, attitudes to preventer inhaler use, inhaler technique review and respiratory specialist review between patients who accurately reported 'wellcontrolled' asthma and those who did not. Independent risk factors associated with inaccurately reported 'well-controlled' asthma were: having taken a maximum of 5-12 puffs or more of reliever inhaler on at least one day within the previous 4 weeks; being female; having seen a respiratory specialist more than a year ago (rather than in the previous year); and having required oral corticosteroids for worsening asthma in the previous year. The study highlighted the significant hidden burden associated with under-recognition of poor asthma control, on the part of the patient and the need for targeted interventions designed to address the continuing discrepancy between perceived and actual disease control.
  •  
2.
  • Price, David B., et al. (författare)
  • Inhaler Errors in the CRITIKAL Study : Type, Frequency, and Association with Asthma Outcomes
  • 2017
  • Ingår i: Journal of Allergy and Clinical Immunology. - : Elsevier BV. - 2213-2198 .- 2213-2201. ; 5:4, s. 1071-1081.e9
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Poor inhaler technique has been linked to poor asthma outcomes. Training can reduce the number of inhaler errors, but it is unknown which errors have the greatest impact on asthma outcomes.OBJECTIVE: The CRITical Inhaler mistaKes and Asthma controL study investigated the association between specific inhaler errors and asthma outcomes.METHODS: This analysis used data from the iHARP asthma review service-a multicenter cross-sectional study of adults with asthma. The review took place between 2011 and 2014 and captured data from more than 5000 patients on demographic characteristics, asthma symptoms, and inhaler errors observed by purposefully trained health care professionals. People with asthma receiving a fixed-dose combination treatment with inhaled corticosteroids and long-acting beta agonist were categorized by the controller inhaler device they used-dry-powder inhalers or metered-dose inhalers: inhaler errors were analyzed within device cohorts. Error frequency, asthma symptom control, and exacerbation rate were analyzed to identify critical errors.RESULTS: This report contains data from 3660 patients. Insufficient inspiratory effort was common (made by 32%-38% of dry-powder inhaler users) and was associated with uncontrolled asthma (adjusted odds ratios [95% CI], 1.30 [1.08-1.57] and 1.56 [1.17-2.07] in those using Turbohaler and Diskus devices, respectively) and increased exacerbation rate. In metered-dose inhaler users, actuation before inhalation (24.9% of patients) was associated with uncontrolled asthma (1.55 [1.11-2.16]). Several more generic and device-specific errors were also identified as critical.CONCLUSIONS: Specific inhaler errors have been identified as critical errors, evidenced by frequency and association with asthma outcomes. Asthma management should target inhaler training to reduce key critical errors.
  •  
3.
  • Westerik, Janine A. M., et al. (författare)
  • Characteristics of patients making serious inhaler errors with a dry powder inhaler and association with asthma-related events in a primary care setting
  • 2016
  • Ingår i: Journal of Asthma. - : Informa UK Limited. - 0277-0903 .- 1532-4303. ; 53:3, s. 321-329
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Correct inhaler technique is central to effective delivery of asthma therapy. The study aim was to identify factors associated with serious inhaler technique errors and their prevalence among primary care patients with asthma using the Diskus dry powder inhaler (DPI).Methods: This was a historical, multinational, cross-sectional study (2011-2013) using the iHARP database, an international initiative that includes patient- and healthcare provider-reported questionnaires from eight countries. Patients with asthma were observed for serious inhaler errors by trained healthcare providers as predefined by the iHARP steering committee. Multivariable logistic regression, stepwise reduced, was used to identify clinical characteristics and asthma-related outcomes associated with 1 serious errors.Results: Of 3681 patients with asthma, 623 (17%) were using a Diskus (mean [SD] age, 51 [14]; 61% women). A total of 341 (55%) patients made 1 serious errors. The most common errors were the failure to exhale before inhalation, insufficient breath-hold at the end of inhalation, and inhalation that was not forceful from the start. Factors significantly associated with 1 serious errors included asthma-related hospitalization the previous year (odds ratio [OR] 2.07; 95% confidence interval [CI], 1.26-3.40); obesity (OR 1.75; 1.17-2.63); poor asthma control the previous 4 weeks (OR 1.57; 1.04-2.36); female sex (OR 1.51; 1.08-2.10); and no inhaler technique review during the previous year (OR 1.45; 1.04-2.02).Conclusions: Patients with evidence of poor asthma control should be targeted for a review of their inhaler technique even when using a device thought to have a low error rate.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy