SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Khan Sheroz)
 

Sökning: WFRF:(Khan Sheroz) > (2021) > RF Remote Blood Glu...

RF Remote Blood Glucose Sensor and a Microfluidic Vascular Phantom for Sensor Validation

Yunos, Muhammad Farhan Affendi Mohamad (författare)
Int Islamic Univ Malaysia, Malaysia
Manczak, Remi (författare)
Univ Limoges, France
Guines, Cyril (författare)
Univ Limoges, France
visa fler...
Mansor, Ahmad Fairuzabadi Mohd (författare)
Int Islamic Univ Malaysia, Malaysia
Mak, Wing Cheung (författare)
Linköpings universitet,Sensor- och aktuatorsystem,Tekniska fakulteten
Khan, Sheroz (författare)
Onaizah Coll Engn, Saudi Arabia
Ramli, Noor Amalina (författare)
Int Islamic Univ Malaysia, Malaysia
Pothier, Arnaud (författare)
Univ Limoges, France
Nordin, Anis Nurashikin (författare)
Int Islamic Univ Malaysia, Malaysia
visa färre...
 (creator_code:org_t)
2021-12-03
2021
Engelska.
Ingår i: Biosensors. - : MDPI. - 2079-6374. ; 11:12
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Diabetes has become a major health problem in society. Invasive glucometers, although precise, only provide discrete measurements at specific times and are unsuitable for long-term monitoring due to the injuries caused on skin and the prohibitive cost of disposables. Remote, continuous, self-monitoring of blood sugar levels allows for active and better management of diabetics. In this work, we present a radio frequency (RF) sensor based on a stepped impedance resonator for remote blood glucose monitoring. When placed on top of a human hand, this RF interdigital sensor allows detection of variation in blood sugar levels by monitoring the changes in the dielectric constant of the material underneath. The designed stepped impedance resonator operates at 3.528 GHz with a Q factor of 1455. A microfluidic device structure that imitates the blood veins in the human hand was fabricated in PDMS to validate that the sensor can measure changes in glucose concentrations. To test the RF sensor, glucose solutions with concentrations ranging from 0 to 240 mg/dL were injected into the fluidic channels and placed underneath the RF sensor. The shifts in the resonance frequencies of the RF sensor were measured using a network analyzer via its S-11 parameters. Based on the change in resonance frequencies, the sensitivity of the biosensor was found to be 264.2 kHz/mg center dot dL(-1) and its LOD was calculated to be 29.89 mg/dL.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Nyckelord

blood glucose monitoring; diabetes; non-invasive sensor; PDMS; vascular phantom; glucometer; RF sensor

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy