SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lokshin Anna E.)
 

Sökning: WFRF:(Lokshin Anna E.) > (2010) > Temporal reliabilit...

Temporal reliability of cytokines and growth factors in EDTA plasma

Clendenen, Tess V (författare)
Arslan, Alan A (författare)
Lokshin, Anna E (författare)
visa fler...
Idahl, Annika (författare)
Umeå universitet,Obstetrik och gynekologi
Hallmans, Göran, 1947- (författare)
Umeå universitet,Näringsforskning
Koenig, Karen L (författare)
Marrangoni, Adele M (författare)
Nolen, Brian M (författare)
Ohlson, Nina (författare)
Umeå universitet,Patologi
Zeleniuch-Jacquotte, Anne (författare)
Lundin, Eva (författare)
Umeå universitet,Patologi
visa färre...
 (creator_code:org_t)
2010-11-13
2010
Engelska.
Ingår i: BMC research notes. - : Springer Science and Business Media LLC. - 1756-0500. ; 3:1, s. 302-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Cytokines are involved in the development of chronic diseases, including cancer. It is important to evaluate the temporal reproducibility of cytokines in plasma prior to conducting epidemiologic studies utilizing these markers. FINDINGS: We assessed the temporal reliability of CRP, 22 cytokines and their soluble receptors (IL-1alpha, IL-1beta, IL-1Ra, IL-2, sIL-2R, IL-4, IL-5, IL-6, sIL-6R, IL-7, IL-8, IL-10, IL-12p40, IL-12p70, IL-13, IL-15, IL-17, TNFalpha, sTNF-R1, sTNF-R2, IFNalpha, IFNgamma) and eight growth factors (GM-CSF, EGF, bFGF, G-CSF, HGF, VEGF, EGFR, ErbB2) in repeated EDTA plasma samples collected an average of two years apart from 18 healthy women (age range: 42-62) enrolled in a prospective cohort study. We also estimated the correlation between serum and plasma biomarker levels using 18 paired clinical samples from postmenopausal women (age range: 75-86). Twenty-six assays were able to detect their analytes in at least 70% of samples. Of those 26 assays, we observed moderate to high intra-class correlation coefficients (ICCs)(ranging from 0.53-0.89) for 22 assays, and low ICCs (0-0.47) for four assays. Serum and plasma levels were highly correlated (r > 0.6) for most markers, except for seven assays (r < 0.5). CONCLUSIONS: For 22 of the 31 biomarkers, a single plasma measurement is a reliable estimate of a woman's average level over a two-year period.

Nyckelord

MEDICINE
MEDICIN
Pathology
patologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy