1.
  • Gjertsson, Peter, et al. (författare)
  • The added value of ECG-gating for the diagnosis of myocardial infarction using myocardial perfusion scintigraphy and artificial neural networks
  • 2006
  • Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961. ; 26:5, s. 301-304
  • Tidskriftsartikel (refereegranskat)abstract
    • To assess the value of ECG-gating for the diagnosis of myocardial infarction using myocardial perfusion scintigraphy (MPS) and an artificial neural network. A total of 422 patients referred for MPS were studied using a one day Tc-99m-tetrofosmin protocol. Adenosine stress combined with submaximal dynamic exercise was used. The images were interpreted by one of three experienced clinicians and these interpretations regarding the presence or absence of myocardial infarction were used as the standard. A fully automated method using artificial neural networks was compared with the clinical interpretation. Either perfusion data alone or a combination of perfusion and function from ECG-gated images were used as input to different artificial neural networks. After a training session, the two types of neural networks were evaluated in separate test groups using an eightfold cross-validation procedure. The neural networks trained with both perfusion and ECG-gated images had a 4-7% higher specificity compared with the corresponding networks using perfusion data only, in four of five segments compared at the same level of sensitivity. The greatest improvement in specificity, from 70% to 77%, was seen in the inferior segment. In the septal and lateral segments the specificity rose from 73% to 77% and from 81% to 85%, respectively. In the anterior segment, the increase in specificity from 93% to 94% by adding functional data was not significant. The addition of functional information from ECG-gated MPS is of value for the diagnosis of myocardial infarction using an automated method of interpreting myocardial perfusion images.
  •  
2.
  • Lomsky, Milan, 1948, et al. (författare)
  • A new automated method for analysis of gated-SPECT images based on a three-dimensional heart shaped model
  • 2005
  • Ingår i: Clin Physiol Funct Imaging. - 1475-0961. ; 25:4, s. 234-40
  • Tidskriftsartikel (refereegranskat)abstract
    • A new automated method for quantification of left ventricular function from gated-single photon emission computed tomography (SPECT) images has been developed. The method for quantification of cardiac function (CAFU) is based on a heart shaped model and the active shape algorithm. The model contains statistical information of the variability of left ventricular shape. CAFU was adjusted based on the results from the analysis of five simulated gated-SPECT studies with well defined volumes of the left ventricle. The digital phantom NURBS-based Cardiac-Torso (NCAT) and the Monte-Carlo method SIMIND were used to simulate the studies. Finally CAFU was validated on ten rest studies from patients referred for routine stress/rest myocardial perfusion scintigraphy and compared with Cedar-Sinai quantitative gated-SPECT (QGS), a commercially available program for quantification of gated-SPECT images. The maximal differences between the CAFU estimations and the true left ventricular volumes of the digital phantoms were 11 ml for the end-diastolic volume (EDV), 3 ml for the end-systolic volume (ESV) and 3% for the ejection fraction (EF). The largest differences were seen in the smallest heart. In the patient group the EDV calculated using QGS and CAFU showed good agreement for large hearts and higher CAFU values compared with QGS for the smaller hearts. In the larger hearts, ESV was much larger for QGS than for CAFU both in the phantom and patient studies. In the smallest hearts there was good agreement between QGS and CAFU. The findings of this study indicate that our new automated method for quantification of gated-SPECT images can accurately measure left ventricular volumes and EF.
  •  
3.
  •  
4.
  • Lomsky, Milan, et al. (författare)
  • Evaluation of a decision support system for interpretation of myocardial perfusion gated SPECT
  • 2008
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 35:8, s. 1523-1529
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose We have recently presented a decision support system for interpreting myocardial perfusion scintigraphy (MPS). In this study, we wanted to evaluate the system in a separate hospital from where it was trained and to compare it with a quantification software package. Methods A completely automated method based on neural networks was trained for the interpretation of MPS regarding myocardial ischaemia and infarction using 418 MPS from one hospital. Features from each examination describing rest and stress perfusion, regional and global function were used as inputs to different neural networks. After the training session, the system was evaluated using 532 MPS from another hospital. The test images were also processed with the quantification software package Emory Cardiac Toolbox (ECTb). The images were interpreted by experienced clinicians at both the training and the test hospital, regarding the presence or absence of myocardial ischaemia and/or infarction and these interpretations were used as gold standard. Results The neural network showed a sensitivity of 90% and a specificity of 85% for myocardial ischaemia. The specificity for the ECTb was 46% (p < 0.001), measured at the same sensitivity. The neural network sensitivity for myocardial infarction was 89% and the specificity 96%. The corresponding specificity for the ECTb was 54% (p < 0.001). Conclusions A decision support system based on neural networks presents interpretations more similar to experienced clinicians compared to a conventional automated quantification software package. This study shows the feasibility of disseminating the expertise of experienced clinicians to less experienced physicians by the use of neural networks.
  •  
5.
  • Lomsky, Milan, et al. (författare)
  • Normal limits for left ventricular ejection fraction and volumes determined by gated single photon emission computed tomography - a comparison between two quantification methods
  • 2008
  • Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961. ; 28:3, s. 169-173
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare gender-related normal limits for left ventricular (LV) ejection fraction (EF), end-diastolic and end-systolic volumes (EDV and ESV), obtained using two myocardial perfusion-gated single photon emission computed tomography (SPECT) quantification methods. A total of 185 patients were retrospectively selected from a consecutive series of patients examined for coronary artery disease (CAD) or for management of known CAD. Patients were included in the study group if they had normal or probably normal results with stress and rest perfusion imaging and if the combined interpretation of perfusion studies and gated rest studies showed no signs or suspicion of myocardial infarction. The gated SPECT studies were performed using a 2-day stress/gated rest Tc-99m sestamibi protocol. All patient studies were processed using CAFU and quantitative-gated SPECT (QGS), the two software packages for quantification of gated SPECT images. The lower normal limits for EF were higher for CAFU compared with QGS for both women (59% versus 53%) and men (54% versus 47%). The upper normal limits for EDV were also higher for CAFU compared with QGS for both women (133 versus 107 ml) and men (182 versus 161 ml). The differences between the software packages were small for ESV (women 44 versus 44 ml; men 69 versus 74 ml). Gender-specific normal limits need to be applied for LV EF and volumes determined by gated SPECT. Separate criteria for abnormal LV EF and EDV need to be used for women and men depending on the software package used.
  •  
6.
  • Lomsky, Milan, 1948, et al. (författare)
  • Validation of a new automated method for analysis of gated-SPECT images
  • 2006
  • Ingår i: Clin Physiol Funct Imaging. - 1475-0961. ; 26:3, s. 139-45
  • Tidskriftsartikel (refereegranskat)abstract
    • We recently presented a new method for quantification of CArdiac FUnction--denoted CAFU--as the first step in the development of an automated method for integrated interpretation of gated myocardial perfusion single photon emission computed tomography (SPECT) images. The aim of this study was to validate CAFU in the assessment of global and regional function of the left ventricle. Quantitative gated-SPECT (QGS), the most widely used software package for quantification of gated-SPECT images, was used as reference method for the measurements of ejection fraction (EF) and ventricular volumes, and visual analysis by an experienced physician was used as reference method for the measurements of regional wall motion and thickening. Two different groups of consecutive patients referred for myocardial perfusion scintigraphy were studied. Global function was evaluated in 316 patients and regional function in 49 other patients. The studies were performed using a 2-day stress/rest 99 m-Tc-sestamibi protocol. A good correlation was found between EF values from QGS and CAFU (EF CAFU = 0.84 EF QGS + 13, r = 0.94), but CAFU values were on average 4 EF points higher than QGS values. With CAFU the segments with normal thickening according to the physician showed significantly higher thickening values (in all parts of the myocardium) compared to the segments classified as having abnormal thickening. In conclusion, this study demonstrates that CAFU can be used to quantify global and regional function in gated-SPECT images. This is an important step in our development of an automated method for integrated interpretation of gated-SPECT myocardial perfusion scintigraphy studies.
  •  
Skapa referenser, mejla, bekava och länka