SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Matson M) srt2:(2005-2009)"

Sökning: WFRF:(Matson M) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Abdesselam, A., et al. (författare)
  • The ATLAS semiconductor tracker end-cap module
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 575:3, s. 353-389
  • Tidskriftsartikel (refereegranskat)abstract
    • The challenges for the tracking detector systems at the LHC are unprecedented in terms of the number of channels, the required read-out speed and the expected radiation levels. The ATLAS Semiconductor Tracker. (SCT) end-caps have a total of about 3 million electronics channels each reading out every 25 ns into its own on-chip 3.3 mu s buffer. The highest anticipated dose after 10 years operation is 1.4x10(14) cm(-2) in units of 1 MeV neutron equivalent (assuming the damage factors scale with the non-ionising energy loss). The forward tracker has 1976 double-sided modules, mostly of area similar to 70 cm(2), each having 2 x 768 strips read out by six ASICs per side. The requirement to achieve an average perpendicular radiation length of 1.5% X-0, while coping with up to 7 W dissipation per module (after irradiation), leads to stringent constraints on the thermal design. The additional requirement of 1500e(-) equivalent noise charge (ENC) rising to only 1800e(-) ENC after irradiation, provides stringent design constraints on both the high-density Cu/Polyimide flex read-out circuit and the ABCD3TA read-out ASICs. Finally, the accuracy of module assembly must not compromise the 16 mu m (r phi) resolution perpendicular to the strip directions or 580 mu m radial resolution coming from the 40 mrad front-back stereo angle. A total of 2210 modules were built to the tight tolerances and specifications required for the SCT. This was 234 more than the 1976 required and represents a yield of 93%. The component flow was at times tight, but the module production rate of 40-50 per week was maintained despite this. The distributed production was not found to be a major logistical problem and it allowed additional flexibility to take advantage of where the effort was available, including any spare capacity, for building the end-cap modules. The collaboration that produced the ATLAS SCT end-cap modules kept in close contact at all times so that the effects of shortages or stoppages at different sites could be rapidly resolved.
  •  
2.
  • Abdesselam, A., et al. (författare)
  • The barrel modules of the ATLAS semiconductor tracker
  • 2006
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 568:2, s. 642-671
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper describes the silicon microstrip modules in the barrel section of the SemiConductor Tracker (SCT) of the ATLAS experiment at the CERN Large Hadron Collider (LHC). The module requirements, components and assembly techniques are given, as well as first results of the module performance on the fully assembled barrels that make up the detector being installed in the ATLAS experiment.
  •  
3.
  •  
4.
  • Vesikari, Timo, et al. (författare)
  • Safety and efficacy of a pentavalent human-bovine (WC3) reassortant rotavirus vaccine.
  • 2006
  • Ingår i: N Engl J Med. - 1533-4406. ; 354:1, s. 23-33
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Rotavirus is a leading cause of childhood gastroenteritis and death worldwide. METHODS: We studied healthy infants approximately 6 to 12 weeks old who were randomly assigned to receive three oral doses of live pentavalent human-bovine (WC3 strain) reassortant rotavirus vaccine containing human serotypes G1, G2, G3, G4, and P[8] or placebo at 4-to-10-week intervals in a blinded fashion. Active surveillance was used to identify subjects with serious adverse and other events. RESULTS: The 34,035 infants in the vaccine group and 34,003 in the placebo group were monitored for serious adverse events. Intussusception occurred in 12 vaccine recipients and 15 placebo recipients within one year after the first dose including six vaccine recipients and five placebo recipients within 42 days after any dose (relative risk, 1.6; 95 percent confidence interval, 0.4 to 6.4). The vaccine reduced hospitalizations and emergency department visits related to G1-G4 rotavirus gastroenteritis occurring 14 or more days after the third dose by 94.5 percent (95 percent confidence interval, 91.2 to 96.6 percent). In a nested substudy, efficacy against any G1-G4 rotavirus gastroenteritis through the first full rotavirus season after vaccination was 74.0 percent (95 percent confidence interval, 66.8 to 79.9 percent); efficacy against severe gastroenteritis was 98.0 percent (95 percent confidence interval, 88.3 to 100 percent). The vaccine reduced clinic visits for G1-G4 rotavirus gastroenteritis by 86.0 percent (95 percent confidence interval, 73.9 to 92.5 percent). CONCLUSIONS: This vaccine was efficacious in preventing rotavirus gastroenteritis, decreasing severe disease and health care contacts. The risk of intussusception was similar in vaccine and placebo recipients. (ClinicalTrials.gov number, NCT00090233.) Copyright 2006 Massachusetts Medical Society.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy