SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Mitra Raj)
 

Search: WFRF:(Mitra Raj) > (2008-2009) > Accelerator beam da...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Accelerator beam data commissioning equipment and procedures : report of the TG-106 of the Therapy Physics Committee of the AAPM

Das, Indra J. (author)
Cheng, Chee-Wai (author)
Watts, Ronald J. (author)
show more...
Ahnesjö, Anders, 1953- (author)
Uppsala universitet,Enheten för onkologi
Gibbons, John (author)
Li, X. Allen (author)
Lowenstein, Jessica (author)
Mitra, Raj K. (author)
Simon, William E. (author)
Zhu, Timothy C. (author)
show less...
 (creator_code:org_t)
2008-08-22
2008
English.
In: Medical physics (Lancaster). - : Wiley. - 0094-2405. ; 35:9, s. 4186-4215
  • Research review (peer-reviewed)
Abstract Subject headings
Close  
  • For commissioning a linear accelerator for clinical use, medical physicists are faced with many challenges including the need for precision, a variety of testing methods, data validation, the lack of standards, and time constraints. Since commissioning beam data are treated as a reference and ultimately used by treatment planning systems, it is vitally important that the collected data are of the highest quality to avoid dosimetric and patient treatment errors that may subsequently lead to a poor radiation outcome. Beam data commissioning should be performed with appropriate knowledge and proper tools and should be independent of the person collecting the data. To achieve this goal, Task Group 106 (TG-106) of the Therapy Physics Committee of the American Association of Physicists in Medicine was formed to review the practical aspects as well as the physics of linear accelerator commissioning. The report provides guidelines and recommendations on the proper selection of phantoms and detectors, setting up of a phantom for data acquisition (both scanning and no-scanning data), procedures for acquiring specific photon and electron beam parameters and methods to reduce measurement errors (<1%), beam data processing and detector size convolution for accurate profiles. The TG-106 also provides a brief.discussion on the emerging trend in Monte Carlo simulation techniques in photon and electron beam commissioning. The procedures described in this report should assist a qualified medical physicist in either measuring a complete set of beam data, or in verifying a subset of data before initial use or for periodic quality assurance measurements. By combining practical experience with theoretical discussion, this document sets a new standard for beam data commissioning.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Accelerator
Commissioning
Data acquisition
Radiological physics
Radiofysik

Publication and Content Type

ref (subject category)
for (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view