SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Norvik Christian) srt2:(2022)"

Sökning: WFRF:(Norvik Christian) > (2022)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • van der Have, Oscar, et al. (författare)
  • Shunt-type plexiform lesions identified in the Sugen5416/Hypoxia rat model of pulmonary arterial hypertension using SPµCT
  • 2022
  • Ingår i: The European respiratory journal. - : European Respiratory Society (ERS). - 1399-3003 .- 0903-1936. ; 59:6
  • Tidskriftsartikel (refereegranskat)abstract
    • We recently described four distinct types of plexiform lesions in human idiopathic and familial pulmonary arterial hypertension (PAH) [1], visualising the three-dimensional lesion structure using synchrotron-based phase-contrast micro-CT (SPµCT). Two types, 1 and 2, are shunt-type lesions that connect pulmonary arteries to the bronchial circulation: type 1 to the vasa vasorum, and type 2 to peribronchial vessels. Type 3 lesions are found peripherally in the lung as spherical structures abruptly terminating the distal pulmonary artery/arteriole, and type 4 are characterised by recanalization of an occluded artery/arteriole. Our observation of type 1 and type 2 lesions in PAH supports previous work which demonstrated intrapulmonary bronchopulmonary anastomoses (IBAs) connected to plexiform lesions in human PAH, suggesting that shunting of blood can occur within lesions in the setting of supra-systemic pulmonary arterial pressure [2]. Further hemodynamic studies of distinct subtypes of plexiform lesions have been hampered by the lack of available animal models with plexiform lesions representative of the full range of lesion types found in human disease. Plexiform lesions have previously been described in the Sugen5416/Hypoxia rat model of pulmonary hypertension when time until sacrifice following hypoxia is extended to 13–14 weeks. Initially plexiform lesions were identified within the lumen as well as outside the vessel as aneurysm-like lesions [3], and recently the latter type was shown to form in supernumerary arteries [4]. However, neither study observed plexiform lesions communicating with the bronchial circulation, possibly because of methodological limitations of the histological analysis.
  •  
2.
  • Dreier, Till, et al. (författare)
  • Radiopaque dyes allow vessel imaging in lung tissue using laboratory phase contrast micro-CT
  • 2022
  • Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. ; 12242
  • Konferensbidrag (refereegranskat)abstract
    • Phase contrast micro-CT is a powerful technique allowing imaging of soft tissue at synchrotrons or using lab- oratory sources. The use of contrast agents is a useful approach when imaging vascular structures. However, common x-ray contrast agents typically rely on heavy metals to increase absorption, which may affect the phase contrast and cause artifacts in the reconstructed volumes. Thus, utilizing an agent with lower attenuation similar to soft tissue is clearly advantageous. Here, we evaluated different colored radiopaque solutions (tissue marking dyes) which had been injected into the vascular system of bovine lung samples, prior to embedding in paraffin. Scans were performed using a micro-focus x-tube calibrated to 10 µm spot size at 70 kV and a photon counting detector with a silicon sensor and 75 µm pixels. The resulting volumes have a voxel size of (25 µm)3, limited by the size of the samples, but sufficient to resolve the vascular system. Experiments confirmed that sufficient perfusion of the vessels with the dyes could be achieved, and the different dyes could be clearly discerned in the reconstructed volumes without causing artifacts allowing to clearly identify features in the soft tissue. Further, the findings were confirmed by histology.Keywords:
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy