SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Reinspach Julia) srt2:(2012)"

Sökning: WFRF:(Reinspach Julia) > (2012)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hertz, Hans, et al. (författare)
  • Laboratory cryo soft X-ray microscopy
  • 2012
  • Ingår i: Journal of Structural Biology. - : Elsevier. - 1047-8477 .- 1095-8657. ; 177:2, s. 267-272
  • Tidskriftsartikel (refereegranskat)abstract
    • Lens-based water-window X-ray microscopy allows two- and three-dimensional (2D and 3D) imaging of intact unstained cells in their near-native state with unprecedented contrast and resolution. Cryofixation is essential to avoid radiation damage to the sample. Present cryo X-ray microscopes rely on synchrotron radiation sources, thereby limiting the accessibility for a wider community of biologists. In the present paper we demonstrate water-window cryo X-ray microscopy with a laboratory-source-based arrangement. The microscope relies on a lambda = 2.48-nm liquid-jet high-brightness laser-plasma source, normal-incidence multilayer condenser optics, 30-nm zone-plate optics, and a cryo sample chamber. We demonstrate 2D imaging of test patterns, and intact unstained yeast, protozoan parasites and mammalian cells. Overview 3D information is obtained by stereo imaging while complete 3D microscopy is provided by full tomographic reconstruction. The laboratory microscope image quality approaches that of the synchrotron microscopes, but with longer exposure times. The experimental image quality is analyzed from a numerical wave-propagation model of the imaging system and a path to reach synchrotron-like exposure times in laboratory microscopy is outlined.
  •  
2.
  • Nilsson, Daniel, et al. (författare)
  • Thermal stability of tungsten zone plates for focusing hard x-ray free-electron laser radiation
  • 2012
  • Ingår i: New Journal of Physics. - : Institute of Physics (IOP). - 1367-2630. ; 14, s. 043010-
  • Tidskriftsartikel (refereegranskat)abstract
    • Diffractive Fresnel zone plates made of tungsten show great promise for focusing hard x-ray free-electron laser (XFEL) radiation to very small spot sizes. However, they have to withstand the high-intensity pulses of the beam without being damaged. This might be problematic since each XFEL pulse will create a significant temperature increase in the zone plate nanostructures and it is therefore crucial that the optics are thermally stable, even for a large number of pulses. Here we have studied the thermal stability of tungsten zone-platelike nanostructures on diamond substrates using a pulsed Nd:YAG laser which creates temperature profiles similar to those expected from XFEL pulses. We found that the structures remained intact up to a laser fluence of 100 mJ cm(-2), corresponding to a 6 keV x-ray fluence of 590 mJ cm-2, which is above typical fluence levels in an unfocused XFEL beam. We have also performed an initial damage experiment at the LCLS hard XFEL facility at SLAC National Accelerator Laboratory, where a tungsten zone plate on a diamond substrate was exposed to 105 pulses of 6 keV x-rays with a pulse fluence of 350 mJ cm-2 without any damage occurring.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy