SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Rudolph Tanja) srt2:(2023)"

Sökning: WFRF:(Rudolph Tanja) > (2023)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Escaned, Javier, et al. (författare)
  • Applied coronary physiology for planning and guidance of percutaneous coronary interventions. A clinical consensus statement from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) of the European Society of Cardiology
  • 2023
  • Ingår i: EuroIntervention. - : Europa Digital & Publishing. - 1774-024X .- 1969-6213. ; 19:6, s. 464-
  • Tidskriftsartikel (refereegranskat)abstract
    • The clinical value of fractional flow reserve and non-hyperaemic pressure ratios are well established in determining an indication for percutaneous coronary intervention (PCI) in patients with coronary artery disease (CAD). In addition, over the last 5 years we have witnessed a shift towards the use of physio-logy to enhance procedural planning, assess post-PCI functional results, and guide PCI optimisation. In this regard, clinical studies have reported compelling data supporting the use of longitudinal vessel analysis, obtained with pressure guidewire pullbacks, to better understand how obstructive CAD contributes to myocardial ischaemia, to establish the likelihood of functionally successful PCI, to identify the presence and location of residual flow-limiting stenoses and to predict long-term outcomes. The introduction of new functional coronary angiography tools, which merge angiographic information with fluid dynamic equations to deliver information equivalent to intracoronary pressure measurements, are now available and potentially also applicable to these endeavours. Furthermore, the ability of longitudinal vessel analysis to predict the functional results of stenting has played an integral role in the evolving field of simulated PCI. Nevertheless, it is important to have an awareness of the value and challenges of physiology-guided PCI in specific clinical and anatomical contexts. The main aim of this European Association of Percutaneous Cardiovascular Interventions clinical consensus statement is to offer up-to-date evidence and expert opin-ion on the use of applied coronary physiology for procedural PCI planning, disease pattern recognition and post-PCI optimisation.
  •  
2.
  • Ludwig, Sebastian, et al. (författare)
  • Transcatheter Mitral Valve Replacement versus Medical Therapy for Secondary Mitral Regurgitation: A Propensity Score-Matched Comparison.
  • 2023
  • Ingår i: Circulation. Cardiovascular interventions. - 1941-7632. ; 16:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Transcatheter mitral valve replacement (TMVR) is an emerging therapeutic alternative for patients with secondary mitral regurgitation (MR). Outcomes of TMVR versus guideline-directed medical therapy (GDMT) have not been investigated for this population. This study aimed to compare clinical outcomes of patients with secondary MR undergoing TMVR versus GDMT alone. Methods: The CHOICE-MI registry included patients with MR undergoing TMVR using dedicated devices. Patients with MR etiologies other than secondary MR were excluded. Patients treated with GDMT alone were derived from the control arm of the COAPT trial. We compared outcomes between the TMVR and GDMT groups, using propensity score (PS)-matching to adjust for baseline differences. Results: After PS-matching, 97 patient pairs undergoing TMVR (72.9±8.7 years, 60.8% male, transapical access 91.8%) versus GDMT (73.1±11.0 years, 59.8% male) were compared. At 1 and 2 years, residual MR was ≤1+ in all patients of the TMVR group compared to 6.9% and 7.7%, respectively, in those receiving GDMT alone (both p<0.001). The 2-year rate of HF hospitalization was significantly lower in the TMVR group (32.8% vs. 54.4%, HR 0.59, 95% CI 0.35-0.99; p=0.04). Among survivors, a higher proportion of patients were in NYHA functional class I or II in the TMVR group at 1 year (78.2% vs. 59.7%, p=0.03) and at 2 years (77.8% vs. 53.2%, p=0.09). Two-year mortality was similar in the two groups (TMVR vs. GDMT, 36.8% vs. 40.8%, HR 1.01, 95% CI 0.62-1.64; p=0.98). Conclusions: In this observational comparison, over 2-year follow-up, TMVR using mostly transapical devices in patients with secondary MR was associated with significant reduction of MR, symptomatic improvement, less frequent hospitalizations for HF and similar mortality compared with GDMT.
  •  
3.
  • Rosseel, Liesbeth, et al. (författare)
  • Contemporary European practice in transcatheter aortic valve implantation: results from the 2022 European TAVI Pathway Registry.
  • 2023
  • Ingår i: Frontiers in cardiovascular medicine. - 2297-055X. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • A steep rise in the use of transcatheter aortic valve implantation (TAVI) for the management of symptomatic severe aortic stenosis occurred. Minimalist TAVI procedures and streamlined patient pathways within experienced Heart Valve Centres are designed to overcome the challenges of ever-increasing procedural volume.The 2022 European TAVI Pathway Survey aims to describe contemporary TAVI practice across Europe.Between October and December 2022, TAVI operators from 32 European countries were invited to complete an online questionnaire regarding their current practice.Responses were available from 147 TAVI centres in 26 countries. In 2021, the participating centres performed a total number of 27,223 TAVI procedures, with a mean of 185 TAVI cases per centre (median 138; IQR 77-194). Treatment strategies are usually (87%) discussed at a dedicated Heart Team meeting. Transfemoral TAVI is performed with local anaesthesia only (33%), with associated conscious sedation (60%), or under general anaesthesia (7%). Primary vascular access is percutaneous transfemoral (99%) with secondary radial access (52%). After uncomplicated TAVI, patients are transferred to a high-, medium-, or low-care unit in 28%, 52%, and 20% of cases, respectively. Time to discharge is day 1 (12%), day 2 (31%), day 3 (29%), or day 4 or more (28%).Reported adoption of minimalist TAVI techniques is common among European TAVI centres, but rates of next-day discharge remain low. This survey highlights the significant progress made in refining TAVI treatment and pathways in recent years and identifies possible areas for further improvement.
  •  
4.
  • Rück, Andreas, et al. (författare)
  • The Early neo2 Registry : Transcatheter Aortic Valve Implantation With ACURATE neo2 in a European Population
  • 2023
  • Ingår i: Journal of the American Heart Association. - 2047-9980. ; 12:15
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. METHODS AND RESULTS: The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory–adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. CONCLUSIONS: In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.
  •  
5.
  • Rudolph, Tanja, et al. (författare)
  • Modifiable risk factors for permanent pacemaker after transcatheter aortic valve implantation: CONDUCT registry
  • 2023
  • Ingår i: Open heart. - : BMJ PUBLISHING GROUP. - 2053-3624. ; 10:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective The onset of new conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is still a relevant adverse event. The main objective of this registry was to identify modifiable procedural risk factors for an improved outcome (lower rate of PPI) after TAVI in patients at high risk of PPI.Methods Patients from four European centres receiving a balloon-expandable TAVI (Edwards SAPIEN 3/3 Ultra) and considered at high risk of PPI (pre-existing conduction disturbance, heavily calcified left ventricular outflow tract or short membranous septum) were prospectively enrolled into registry.Results A total of 300 patients were included: 42 (14.0%) required PPI after TAVI and 258 (86.0%) did not. Patients with PPI had a longer intensive care unit plus intermediate care stay (65.7 vs 16.3 hours, p < 0.001), general ward care stay (6.9 vs 5.3 days, p=0.004) and later discharge (8.6 vs 5.0 days, p < 0.001). Of the baseline variables, only pre-existing right bundle branch block at baseline (OR 6.8, 95% CI 2.5 to 18.1) was significantly associated with PPI in the multivariable analysis. Among procedure-related variables, oversizing had the highest impact on the rate of PPI: higher than manufacturer-recommended sizing, mean area oversizing as well as the use of the 29 mm valve (OR 3.4, 95% CI 1.4 to 8.5, p=0.008) all were significantly associated with PPI. Rates were higher with the SAPIEN 3 (16.1%) vs SAPIEN 3 Ultra (8.5%), although not statistically significant but potentially associated with valve sizing. Implantation depth and postdelivery balloon dilatation also tended to affect PPI rates but without a statistical significance.Conclusion Valve oversizing is a strong procedure-related risk factor for PPI following TAVI. The clinical impact of the valve type (SAPIEN 3), implantation depth, and postdelivery balloon dilatation did not reach significance and may reflect already refined procedures in the participating centres, giving attention to these avoidable risk factors.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy