Fixation of Spinal Implants : Clinical and Experimental Studies on the Effects of Hydroxyapatite Coating

Sandén, Bengt (författare)
Uppsala universitet,Institutionen för kirurgiska vetenskaper
Ohlin, Acke, Docent (opponent)
Inst f medicin, kirurgi, ortopedi, Avd f ortopedi, Malmö
 (creator_code:org_t)
ISBN 9155451373
Uppsala : Acta Universitatis Upsaliensis, 2001
Engelska 48 s.
Serie: Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, 0282-7476 ; 1085
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • Loosening of implants is a frequent complication in orthopaedic surgery. The aim of this thesis was to evaluate hydroxyapatite coating of pedicle screws with mechanical and histological methods and to correlate the results with the radiological findings.Hydroxyapatite (HA) coating of pedicle screws was investigated in experimental studies in sheep. Nine sheep were operated on with destabilising laminectomies at L2-L3 and L4-L5 and stabilised with pedicle screw instrumentations, where HA coated and uncoated screws were used in a randomised fashion. After both 6 and 12 weeks of implantation, the HA coated screws demonstrated a higher bone-to-implant contact and a higher amount of bone in the area close to the screw. The pull-out resistance, stiffness and total energy to failure was higher for the HA coated screws after 12 weeks of implantation.HA coating of pedicle screws was examined in two clinical studies. In the first series, the patients were stabilised with pedicle screw instrumentations, where HA coated screws were used in either the upper or lower instrumented level in a randomised fashion. After 10-22 months of implantation, the extraction torque was markedly higher for the HA coated screws. In the second series, instrumentations with uncoated, partly HA coated or fully HA coated screws were used. After 11-16 months implantation, the extraction torques were recorded. There were significant differences between all three groups, with the lowest extraction torques for the uncoated screws and the highest torques for the fully HA coated screws. The frequency of radiolucent zones surrounding the screws was higher for the uncoated screws than for the HA coated screws.Radiographs from both experimental and clinical studies were examined. Screws demonstrating radiolucent zones were compared to screws without zones with respect to pull-out resistance, extraction torque, bone-to-implant contact and amount of bone surrounding the screws. All these variables demonstrated higher values for the screws without radiolucent zones. The frequency of radiolucent zones surrounding uncoated screws in the clinical study was 53%.Conclusions: Radiolucent zones are good predictors of screw loosening. The frequency of radiolucent zones is higher than previously described. Hydroxyapatite coating improves the purchase of pedicle screws and reduces the frequency of screw loosening.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Surgery
Hydroxyapatite
pedicle screw
histomorphometry
fixation
radiolucent zones
screw loosening
Kirurgi
Surgery
Kirurgi
Orthopaedics
ortopedi

Publikations- och innehållstyp

vet (ämneskategori)
dok (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sandén, Bengt
Ohlin, Acke, Doc ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kirurgi
Delar i serien
Comprehensive Su ...
Av lärosätet
Uppsala universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy