SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sarmento A.) srt2:(2023)"

Sökning: WFRF:(Sarmento A.) > (2023)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Tarrío, Diego, et al. (författare)
  • Neutron-induced fission cross sections of Th-232 and U-233 up to 1 GeV using parallel plate avalanche counters at the CERN n_TOF facility
  • 2023
  • Ingår i: Physical Review C. - : American Physical Society. - 2469-9985 .- 2469-9993. ; 107:4
  • Tidskriftsartikel (refereegranskat)abstract
    • The neutron-induced fission cross sections of Th-232 and U-233 were measured relative to U-235 in a wide neutron energy range up to 1 GeV (and from fission threshold in the case of Th-232, and from 0.7 eV in case of U-233), using the white-spectrum neutron source at the CERN Neutron Time-of-Flight (n_TOF) facility. Parallel plate avalanche counters (PPACs) were used, installed at the Experimental Area 1 (EAR1), which is located at 185 m from the neutron spallation target. The anisotropic emission of fission fragments were taken into account in the detection efficiency by using, in the case of U-233, previous results available in EXFOR, whereas in the case of Th-232 these data were obtained from our measurement, using PPACs and targets tilted 45 degrees with respect to the neutron beam direction. Finally, the obtained results are compared with past measurements and major evaluated nuclear data libraries. Calculations using the high-energy reaction models INCL++ and ABLA07 were performed and some of their parameters were modified to reproduce the experimental results. At high energies, where no other neutron data exist, our results are compared with experimental data on proton-induced fission. Moreover, the dependence of the fission cross section at 1 GeV with the fissility parameter of the target nucleus is studied by combining those ( p, f) data with our (n, f) data on Th-232 and U-233 and on other isotopes studied earlier at n_TOF using the same experimental setup.
  •  
2.
  • Ayeni, O. R., et al. (författare)
  • Clinical and Radiographic Criteria Define "Acceptable" Surgical Correction of Hip Femoroacetabular Impingement Syndrome as Well as Postoperative Complications: An International Modified Delphi Study
  • 2023
  • Ingår i: Arthroscopy-the Journal of Arthroscopic and Related Surgery. - : Elsevier BV. - 0749-8063. ; 39:5, s. 1198-1210
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To develop recommendations for clinical and radiographic criteria to help define the "acceptable" surgical correction of femoroacetabular impingement syndrome (FAIS) and identify/define complications postoperatively. Methods: A 3-phase modified Delphi study was conducted involving a case-based survey; a Likert/multiple choice-based survey concerning radiographic and physical examination characteristics to help define FAIS correction, as well as the prevalence and definition of potential postoperative complications; and 2 consensus meetings. Results: Of the 75 experts invited, 54 completed the Phase I survey, 50 completed the Phase II survey (72% and 67% response rate), and 50 participated in the Phase III consensus meetings. For both typical and atypical (complex) cases, there was consensus that fluoroscopy with multiple views and dynamic hip assessment should be used intraoperatively (96% and 100%, respectively). For typical FAIS cases, the Expert Panel agreed that Dunn lateral and anteroposterior radiographs were the most important radiographs to evaluate the hip postoperatively (88%, consensus). When asked about evaluating the correction of cam impingement postoperatively, 87% voted that they use subjective evaluation of the "sphericity" of the femoral head. In the case of focal and global pincer-type FAIS, there was consensus that the reduction or elimination of the crossover sign (84%) and lateral center-edge angle (91%) were important to inform the extent of the FAIS correction. There was consensus for recommending further investigation at 6 months postoperatively if hip pain had increased/plateaued (92% agreed); that additional investigation and treatment should occur between 6 and 12 months (90% agreed); and that a reoperation may be recommended at 12 months or later following this investigation period (89% agreed). Conclusions: This consensus project identified the importance of using fluoroscopy and dynamic hip assessment intraoperatively; Dunn lateral and anteroposterior view radiographs postoperatively; evaluating the "sphericity" of the femoral head for cam-type correction and the use of dynamic hip assessment; reducing/eliminating the crossover sign for focal pincertype FAIS; evaluating the lateral center-edge angle for global pincer-type FAIS; and avoiding overcorrection of pincer-type FAIS. In cases in which postoperative hip pain increased/plateaued, further investigation and treatment is warranted between 6 and 12 months, and a reoperation may be recommended at a minimum of 12 months depending on the cause of the hip pain. Clinical Relevance: Hip arthroscopy surgeons have yet to reach a firm agreement on what constitutes an "acceptable" or "good" surgery radiographically and how they can achieve desired clinical outcomes. Although this was a comprehensive effort, more study is needed to determine therapeutic thresholds that can be universally applied.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy