SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Schropp Andreas) srt2:(2014)"

Sökning: WFRF:(Schropp Andreas) > (2014)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Correa, Leticia, et al. (författare)
  • Planning of dental implant size with digital panoramic radiographs, CBCT-generated panoramic images, and CBCT cross-sectional images
  • 2014
  • Ingår i: Clinical Oral Implants Research. - : Blackwell Munksgaard. - 0905-7161 .- 1600-0501. ; 25:6, s. 690-695
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES: To compare the implant size (width and length) planned with digital panoramic radiographs, cone beam computed tomography (CBCT)-generated panoramic views, or CBCT cross-sectional images, in four implant systems. MATERIAL AND METHODS: Seventy-one patients with a total of 103 implant sites in the upper premolar and/or lower molar regions were examined with digital panoramic radiography (D-PAN) and (CBCT). A metal ball 5 mm in diameter was placed in the edentulous area for the D-PAN. CBCT data sets were reformatted to a 10-mm thick CBCT panoramic view (CBCT-pan) and 1-mm cross-sections (CBCT-cross). Measurements were performed in the images using dedicated software. All images were displayed on a monitor and assessed by three observers who outlined a dental implant by placing four reference points in the site of the implant-to-be. Differences in width and length of the implant-to-be from the three modalities were analyzed. The implant size selected in the CBCT-cross images was then compared to that selected in the other two modalities (D-PAN and CBCT-pan) for each of the implant systems separately. RESULTS: The implant-to-be (average measurements among observers) was narrower when measured in CBCT-cross compared with both D-PAN and CBCT-Pan. For premolar sites, the width also differed significantly between D-PAN and CBCT-pan modalities. The implant-to-be was also significantly shorter when recorded in CBCT-cross than in D-PAN. In premolar sites, there were no significant differences in implant length among the three image modalities. It mattered very little for the change in implant step sizes whether CBCT-cross was compared to D-PAN or CBCT-pan images. CONCLUSION: Our results show that the selected implant size differs when planned on panoramic or cross-section CBCT images. In most cases, implant size measured in cross-section images was narrower and shorter than implant size measured in a panoramic image or CBCT-based panoramic view
  •  
2.
  • Schropp, Lars, et al. (författare)
  • Early, delayed, or late single implant placement : 10-year results from a randomized controlled clinical trial
  • 2014
  • Ingår i: Clinical Oral Implants Research. - : John Wiley & Sons. - 0905-7161 .- 1600-0501. ; 25:12, s. 1359-1365
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: The aim of this study was to present the 10-year clinical and radiographic data from a RCT on single-tooth implants placed early, delayed, or late after tooth extraction. Materials and Methods: Sixty-three patients were randomly allocated to three groups and received an implant on average 10 days (Ea), 3 months (De), or 17 months (La) after tooth extraction. Second-stage surgery was performed after 3 months of submerged healing; metal-ceramic crowns were cemented after one additional month. Standardized periapical radiographs were taken 1 week after implant placement (TP), 1 week (TC) and 1–1.5 year (T1) after crown delivery, and 10 years after implant placement (T10). Pocket depth (PD) and bleeding on probing were registered during controls (TC – T10). Results: Two Ea and one De implants failed to osseointegrate. Seven patients (4 Ea, 1 De, and 2 La) were not available at T10. No significant differences were found among groups regarding implant survival or radiographic peri-implant marginal bone levels (Ea: 1.15 0.77; De: 1.53 1.06; La: 1.42 1.07) at T10. Similarly, no differences were observed among groups in the number of implants with PD ≥5 mm (Ea: 29%; De: 35%; La: 44%) or the average depth of the sites with PD ≥5 mm (Ea: 5.4 0.7; De: 6.1 1.4; La: 5.4 0.5) at T10. Peri-implant mucositis was found in 70% of the cases; peri-implantitis was diagnosed only in two implants (1 De, 1 La) corresponding to 4.3%. Conclusion: Single-tooth implants placed early or delayed after tooth extraction show high survival rates and limited peri-implant marginal bone resorption or biological complications, similar to what is observed with implants placed according to the conventional (late) protocol.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Stavropoulos, Andrea ... (2)
Schropp, Lars (2)
Wenzel, Ann (2)
Correa, Leticia (1)
Spin-Neto, Rubens (1)
da Silveira, Heloísa (1)
Lärosäte
Malmö universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy