1.
  • Mandic-Havelka, Aleksandra, et al. (författare)
  • Turbidimetric Determination of Fecal Calprotectin Using Two Table Top Chemistry Analyzers : Mindray BS-200E and Cobas® c111
  • 2017
  • Ingår i: Clinical Laboratory. - 1433-6510. ; 63:5, s. 907-913
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Fecal calprotectin assays are widely used in diagnosis and monitoring of inflammatory bowel disease (IBD) in patients with suspected IBD. The most frequently used technique is ELISA and microtiter plates. Turbidimetric assays for analysis of fecal calprotectin can significantly reduce turnaround time. Many laboratories may be reluctant to run fecal samples on their large chemistry analyzers. The aim of this study was to evaluate fecal calprotectin particle enhanced turbidimetric immunoassay (PETIA) on smaller chemistry analyzers that could be dedicated for fecal samples.METHODS: The BÜHLMANN fCAL® turbo assay was validated on two table top chemistry analyzers, Mindray BS-200E and cobas® c111.RESULTS: The assay was linear in the range between 20 and 1,900 µg/g with a limit of quantification around 20 µg/g on both instruments. The total coefficient of variation was < 7% in the range between 50 and 1,300 µg/g on both instruments. No antigen excess hook effect was observed up to 18,000 µg/g on the Mindray BS-200E and up to 20,000 µg/g on cobas® c111. The BÜHLMANN fCAL® turbo assay showed a high correlation with the BÜHLMANN fCAL® ELISA.CONCLUSIONS: Running the BÜHLMANN fCAL® turbo on Mindray BS-200E or cobas® c111 chemistry analyzers can provide rapid test results without exposing large routine chemistry analyzers to stool samples.
  •  
2.
  • Nilsen, Tom, et al. (författare)
  • A new turbidimetric immunoassay for serum calprotectin for fully automatized clinical analysers
  • 2015
  • Ingår i: Journal of Inflammation. - : Springer Science and Business Media LLC. - 1476-9255. ; 12
  • Tidskriftsartikel (refereegranskat)abstract
    • Serum and plasma calprotectin concentration is shown to be elevated when neutrophils are activated, and may therefore be used as a marker for inflammatory diseases. A serum calprotectin immunoassay was developed based on calprotectin values observed in samples from the intensive care unit. The polyclonal avian antibodies were raised and affinity purified with calprotectin antigens. The performance was tested and it was observed that the assay was linear in the range 0.3-24.7 mg/L, the limit of quantitation was observed to be lower than 0.3 mg/L, no antigen excess was observed up to 54 mg/L, all CVs were lower than 1.8 % in the precision study, the calibration curve stability was longer than 6 weeks, and there was no significant interference detected for haemoglobin, intralipid or bilirubin. The serum calprotectin immunoassay presented in this paper performs well within the criteria carefully set from the limited clinical experience obtained in both serum and plasma. In addition it is commutable with Bühlmann MRP8/14 ELISA.
  •  
3.
  • Nilsen, Tom, et al. (författare)
  • A novel turbidimetric immunoassay for fecal calprotectin optimized for routine chemistry analyzers
  • 2017
  • Ingår i: Journal of clinical laboratory analysis (Print). - : Wiley. - 0887-8013 .- 1098-2825. ; 31:4
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Fecal calprotectin assays are widely used to exclude inflammatory bowel disease (IBD) in patients with suspected IBD. A problem with the fecal calprotectin assays is the rather long test-turnaround times. A particle enhanced turbidimetric immunoassays (PETIA) for fecal calprotectin would reduce test-turnaround times and would permit more laboratories to perform the measurements. The aim of this study was to evaluate a new feces calprotectin PETIA.METHOD: Using routine fecal samples the feces calprotectin PETIA was validated on two chemistry analyzers, Mindray BS-380 and Cobas 501.RESULTS: The assay is linear in the range 11-2000 μg/g, with a limit of quantitation of approximately 10 μg/g. No antigen excess hook effect was observed up to 10 000-15 000 μg/g depending on the instrument used. The turbidimetric method showed a good agreement with the Bühlmann ELISA. The total coefficient of variation was 3%-8% in the 50-100 μg/g range.CONCLUSION: The fecal calprotectin PETIA, fCal Turbo, is well suited for rapid analysis of fecal calprotectin on Mindray BS-380 or Cobas 501 clinical chemistry analyzers. The test results are commutable with Bühlmann fecal MRP8/14 ELISA.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3