SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Syk Jörgen) srt2:(2015-2019)"

Sökning: WFRF:(Syk Jörgen) > (2015-2019)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lodin, Karin, et al. (författare)
  • Associations between self-rated health, sickness behaviour and inflammatory markers in primary care patients with allergic asthma : a longitudinal study
  • 2017
  • Ingår i: npj Primary Care Respiratory Medicine. - : Springer Science and Business Media LLC. - 2055-1010. ; 27
  • Tidskriftsartikel (refereegranskat)abstract
    • Allergic asthma is a chronic inflammatory disorder associated with elevated levels of immunoglobulin E (IgE), serum eosinophilic cationic protein (S-ECP), plasma eosinophil-derived neurotoxin (P-EDN) and fraction of exhaled nitric oxide (FENO). Poor self-rated health and sickness behaviour has repeatedly been associated with inflammatory markers, but the nature of this relationship in chronic inflammatory disease is not known. Likewise, such findings largely rely on cross-sectional investigations. Self-rated health (How would you rate your general state of health?), sickness behaviour (mean rating of satisfaction with energy, sleep, fitness, appetite and memory), IgE, S-ECP, P-EDN, and FENO were assessed in 181 non-smoking primary care patients with asthma in a 1-year longitudinal study. Associations between repeated measurements were calculated using mixed regression models and Spearman's correlations for change scores. Poor self-rated health was associated with high levels of seasonal IgE (p = 0.05) and food IgE (p = 0.04), but not total IgE or inflammatory markers. An increase over 1 year in perennial IgE was associated with a worsening of self-rated health (rho = 0.16, p = 0.04). Poor self-rated health was associated with more pronounced sickness behaviour (p < 0.001), and a worsening in sickness behaviour was associated with a worsening of self-rated health over time (rho = 0.21, p = 0.007). The study corroborates the importance of sickness behaviour as a determinant of self-rated health by showing that these factors co-vary over a 1-year period in a group of patients with allergic asthma. The importance of specific IgE for perceived health in primary care patients with mild to moderate asthma needs further investigation.
  •  
2.
  • Lodin, Karin, et al. (författare)
  • Longitudinal co-variations between inflammatory cytokines, lung function and patient reported outcomes in patients with asthma
  • 2017
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 12:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Asthma is a chronic inflammatory respiratory disorder associated with reduced lung function and poor quality of life. The condition is also associated with poor self-rated health, a major predictor of objective health trajectories. Of biological correlates to self-rated health, evidence suggests a role for inflammatory cytokines and related sickness behaviours. However, this is mainly based on cross-sectional data, and the relation has not been investigated in patients with chronic inflammatory conditions.ObjectiveTo investigate inflammatory cytokines, lung function, sickness behaviour and asthma-related quality of life as determinants of self-rated health in patients with asthma, and to investigate if these variables co-vary over time. Methods Plasma cytokines (IL-5, IL-6), lung function (FEV1), sickness behaviour, asthma-related quality of life and self-rated health were assessed in 181 patients with allergic asthma aged 18-64 years in a one-year longitudinal study. Mixed effect regression models and Spearman's correlation were performed to analyse the associations between repeated measurements.ResultsMore sickness behaviour and poorer asthma-related quality of life were associated with poorer self-rated health (p's<0.001). In men, both low and high levels of interleukin (IL)-6 and poorer lung function were related with poorer self-rated health (p's<0.05). Over the year, improved asthma-related quality of life was associated with better self-rated health (Spearman's rho = -0.34 women,-0.36 men, p's<0.01). Further, if sickness behaviour decreased, self-rated health improved, but only in women (Rho = -0.21, p<0.05). Increased FEV1 in men was associated with an increase in IL-6 (Rho = 0.24, p<0.05) as well as improved self-rated health (Rho = -0.21, p<0.05) and asthma-related quality of life (Rho = 0.29, p<0.01) over the year.ConclusionThe study highlights the importance of subjectively perceived sickness behaviour and asthma-related quality of life together with lung function as determinants of self-rated health in asthmatic patients. The importance of inflammatory activation for patient reported outcomes in chronic inflammatory conditions need further investigation.
  •  
3.
  • Näsvall, Pia, 1967- (författare)
  • Parastomal hernia : investigation and treatment
  • 2015
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • BackgroundParastomal hernia is a common stoma complication causing the patient considerable inconvenience. The patient becomes aware of a bulge around the stoma, but a bulge is not always a parastomal hernia and diagnostics must be performed to enable differential treatment. It is difficult to distinguish between a bulge and a hernia. Results based on clinical examination and computerised tomography (CT) in the supine position, have not been convincing. Three-dimensional intrastomal ultrasonography (3D US) is a novel technique shown to be promising in the assessment of stoma complaints. Two studies were performed to determine inter- and intra-observer reliability as well as the validity of 3D US as an alternative to CT when assessing stoma complaints.There are numerous options for the treatment of parastomal hernia, but none has been shown superior. In the recent decades the use of mesh in the repair of incisional and inguinal hernia has become routine. New materials must be evaluated as there are potential morbidity and even mortality risks with mesh repair. As recurrence of a parastomal hernia is an even greater challenge, the method of choice should have a low risk for recurrence. A prospective multicenter study was performed to evaluate safety and recurrence rate when using Parastomal Hernia Patch BARDTM (PHP), a mesh specially designed for parastomal hernia repair.A stoma has a profound impact on the patient´s daily life, both physical and psychological. A parastomal hernia with its associated risk for leakage and incarceration worsens the situation. Patient driven assessment of healthcare outcome is important if we are to improve medical care. A quality of life (QoL) survey was performed to assess the impact of parastomal bulging and hernia on the patient´s daily life.MethodsForty patients were investigated and the 3D US images were twice evaluated by two or three physicians to assess inter- and intra-observer reliability. Totally 20 patients with stoma complaints requiring surgery were examined with CT and 3D US prior to surgery. The findings were compared with the intraoperative findings – regarded as the true outcome.Fifty patients with parastomal hernia requiring surgery were enrolled from three hospitals. Patients were followed up one month and one year after repair using PHP.Patients still alive in 2008 who had been operated between1996 and 2004 for rectal cancer in Uppsala/Örebro-, Stockholm/Gotland-, and Northern Regions (986 patients) and registered in the Swedish Rectal Cancer Registry (SRCR) were invited to fill in four QoL questionnaires.ResultsInter-observer agreement using 3D US reached 80% for the last 10 patients examined, with a kappa value of 0.70. Intra-observer agreement for two examiners was 80% and 95%. The learning curve levelled out at 30 patients. Both CT and 3D US showed high sensitivity and specificity when compared with intraoperative findings.After surgery for parastomal hernia with a PHP, the complication rate at one month was 30% and recurrence rate at one year was 22%. Twelve patients were reoperated within one year.In the QoL study, 31.5% of the patients with a stoma reported a bulging or a hernia. 11.7% had been operated for parastomal hernia. A hernia or a bulge gave rise to significantly more pain and impaired stoma function. Overall QoL was inferior in patients with a permanent stoma compared to a group without a stoma.
  •  
4.
  • Price, David B., et al. (författare)
  • Fractional exhaled nitric oxide as a predictor of response to inhaled corticosteroids in patients with non-specific respiratory symptoms and insignificant bronchodilator reversibility : a randomised controlled trial
  • 2018
  • Ingår i: The Lancet Respiratory Medicine. - : ELSEVIER SCI LTD. - 2213-2600 .- 2213-2619. ; 6:1, s. 29-39
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Chronic non-specific respiratory symptoms are difficult to manage. This trial aimed to evaluate the association between baseline fractional exhaled nitric oxide (FENO) and the response to inhaled corticosteroids in patients with non-specific respiratory symptoms.Methods: In this double-blind randomised placebo-controlled trial, we enrolled undiagnosed patients, aged 18-80 years, with cough, wheeze, or dyspnoea and less than 20% bronchodilator reversibility across 26 primary care centres and hospitals in the UK and Singapore. Patients were assessed for 2 weeks before being randomly assigned (1: 1) to 4 weeks of treatment with extrafine inhaled corticosteroids (QVAR 80 mu g, two puffs twice per day, equivalent to 800 mu g per day beclomethasone dipropionate) or placebo. Randomisation was stratified by baseline FENO measurement: normal (<= 25 parts per billion [ppb]), intermediate (>25 tp <40 ppb), and high (>= 40 ppb). The primary endpoint was change in Asthma Control Questionnaire (ACQ7) mean score. We used generalised linear modelling to assess FENO as a predictor of response, estimating an interaction effect between FENO and treatment on change in ACQ7. We did our primary and secondary analyses in the per-protocol set, which excluded patients with non-completion of the primary endpoint, non-compliance to treatment (ascertained by patient report), and study visits made outside the predefined visit windows. This study is registered on ClinicalTrials.gov, number NCT02294279.Findings: Between Feb 4, 2015, and July 12, 2016, we randomly assigned 294 patients to extrafine inhaled corticosteroid treatment (n=148) or placebo (n=146). Following exclusions due to protocol violations, we analysed 214 patients (114 extrafine inhaled corticosteroids and 100 placebo). We observed a significant interaction between baseline FENO and treatment group for every 10 ppb increase in baseline FENO, with the change in ACQ7 greater in the extrafine inhaled corticosteroids group than in the placebo group (difference between groups 0.071, 95% CI 0.002 to 0.139; p=0.044). The most common adverse events were nasopharyngitis (18 [12%] patients in the treatment group vs 13 [9%] in the placebo group), infections and infestations (25 [17%] vs 21 [14%]), and respiratory, thoracic, and mediastinal disorders (13 [9%] vs 17 [12%]).Interpretation: FENO measurement is an easy and non-invasive tool to use in clinical practice in patients with nonspecific respiratory symptoms to predict response to inhaled corticosteroids. Further research is needed to examine its role in patients with evidence of other airway diseases, such as chronic obstructive pulmonary disease.
  •  
5.
  • Syk, Jörgen, et al. (författare)
  • A Multicenter, Observational, Prospective Study of the Effectiveness of Switching from Budesonide/Formoterol Turbuhaler® to Budesonide/Formoterol Easyhaler®
  • 2019
  • Ingår i: Advances in Therapy. - : Springer Science and Business Media LLC. - 0741-238X .- 1865-8652. ; 36:7, s. 1756-1769
  • Tidskriftsartikel (refereegranskat)abstract
    • IntroductionIn real-life practice, asthma remains poorly controlled, with a considerable burden on patients’ quality of life. Budesonide/formoterol (B/F) Easyhaler® has demonstrated similar dose consistency, therapeutic equivalence, and equivalent bronchodilator efficacy to B/F Turbuhaler®, but no real-life comparisons are yet available in patients switching from B/F Turbuhaler® to B/F Easyhaler®.MethodsThe primary objective of this real-life, non-interventional, observational study was to show non-inferiority of asthma control when adult patients in Swedish primary care with persistent asthma switched from B/F Turbuhaler® to B/F Easyhaler®. At visit 1, baseline demographic and endpoint data were recorded, and eligible patients switched to B/F Easyhaler®. The study comprised a control visit (visit 2) and a concluding examination (visit 3) after 12 weeks. Asthma control was assessed using the Asthma Control Test (ACT). The mini-Asthma Quality of Life Questionnaire (AQLQ) and lung function test were performed, and participants and investigators answered questionnaires about ease-of-use and teaching.ResultsA total of 117 patients were enrolled in the on-treatment population; 81 (64.8%) were female. At visit 3, B/F Easyhaler® demonstrated non-inferiority to B/F Turbuhaler®; the mean difference in change from baseline ACT was statistically significant (18.9 vs. 20.7, respectively; p < 0.0001) and met the non-inferiority criteria of B/F Easyhaler® being greater than − 1.5 points versus the reference product. Asthma was well controlled in 62 (53.0%) patients at baseline, increasing to 83 patients (70.9%) at visit 3. Patients experienced statistically significant improvements in mini-AQLQ score after B/F Easyhaler® treatment and lung function remained stable across the treatment period. B/F Easyhaler® was easy to learn and prepare for use.ConclusionThis real-life, non-interventional, non-inferiority study in adults with persist asthma demonstrates equivalent or better disease control when patients switch from B/F Turbuhaler® to B/F Easyhaler®. A further study with direct comparison between treatments could add to the understanding of inhaler switch.
  •  
6.
  • Syk, Jörgen, et al. (författare)
  • Parallel reductions of IgE and exhaled nitric oxide after optimized anti-inflammatory asthma treatment
  • 2016
  • Ingår i: Immunity, Inflammation and Disease. - : Wiley. - 2050-4527. ; 4:2, s. 182-190
  • Tidskriftsartikel (refereegranskat)abstract
    • Immunoglobulin E (IgE) is crucial for the development of airway inflammation in atopic asthma, and inhibition of IgE using monoclonal antibodies is now part of asthma therapy. However, the impact of ordinary anti-inflammatory treatment on IgE is unclear. The aim of this study was to investigate if optimization of treatment with inhaled corticosteroid (ICS) and leukotriene-receptor antagonist (LTRA) according to symptoms or exhaled nitric oxide (FENO) levels over a one-year period affects IgE concentrations. Altogether, 158 relatively well-controlled but multi-sensitized asthmatics (age 18-65 years), with ongoing ICS treatment at baseline, were included in this post hoc analysis of data from a randomized, controlled trial on FENO-guided asthma therapy. Asthma control and quality of life (Juniper ACQ and mAQLQ), FENO, and serum IgE were measured at baseline and after one year. Concentrations of IgE antibodies to six common perennial aeroallergens were summed up (perennial IgE). We found that perennial and total IgE decreased by 10.2% and 16.0% (P<. 001 both comparisons). This was not related to allergen exposure, whereas the total use of ICS and LTRA during the year correlated with the reduction in perennial IgE (P = .030 and P = .013). The decrease in perennial and total IgE correlated significantly with the reduction in FENO (P<. 003 and P<. 001), and with improvements in ACQ and mAQLQ scores (P< 0.05, all comparisons). We conclude that one year of optimization of treatment with ICS and LTRA in patients with persistent atopic asthma resulted in significant decreases in total IgE and IgE antibodies; these decreases correlated with a reduction in FENO and improvements in asthma control and quality of life. Thus, IgE is reduced by ordinary asthma controller medications and the effect on IgE seems to be clinically important.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy