SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tao F) srt2:(2005-2009)"

Sökning: WFRF:(Tao F) > (2005-2009)

  • Resultat 1-9 av 9
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ageron, M., et al. (författare)
  • Studies of a full-scale mechanical prototype line for the ANTARES neutrino telescope and tests of a prototype instrument for deep-sea acoustic measurements
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 581:3, s. 695-708
  • Tidskriftsartikel (refereegranskat)abstract
    • full-scale mechanical prototype line was deployed to a depth of 2500 m to test the leak tightness of the electronics containers and the pressure-resistant properties of an electromechanical cable under evaluation for use in the ANTARES deep-sea neutrino telescope. During a month-long immersion study, line parameter data were taken using miniature autonomous data loggers and shore-based optical time domain reflectometry. Details of the mechanical prototype line, the electromechanical cable and data acquisition are presented. Data taken during the immersion study revealed deficiencies in the pressure resistance of the electromechanical cable terminations at the entry points to the electronics containers. The improvements to the termination, which have been integrated into subsequent detection lines, are discussed. The line also allowed deep-sea acoustic measurements with a prototype hydrophone system. The technical setup of this system is described, and the first results of the data analysis are presented. (c) 2007 Elsevier B.V. All rights reserved.
  •  
2.
  • Ageron, M., et al. (författare)
  • The ANTARES optical beacon system
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 578:3, s. 498-509
  • Tidskriftsartikel (refereegranskat)abstract
    • ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented. (C) 2007 Elsevier B.V. All rights reserved.
  •  
3.
  • Aguilar, J. A., et al. (författare)
  • First results of the instrumentation line for the deep-sea ANTARES neutrino telescope
  • 2006
  • Ingår i: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 26:4-5, s. 314-324
  • Tidskriftsartikel (refereegranskat)abstract
    • In 2005, the ANTARES Collaboration deployed and operated at a depth of 2500 m a so-called Mini Instrumentation Line equipped with Optical Modules (MILOM) at the ANTARES site. The various data acquired during the continuous operation from April to December 2005 of the MILOM confirm the satisfactory performance of the Optical Modules, their front-end electronics and readout system. as well as the calibration devices of the detector. The in situ measurement of the Optical Module time response yields a resolution better than 0.5 ns. The performance of the acoustic positioning system, which enables the spatial reconstruction of the ANTARES detector with a precision of about 10 cm, is verified. These results demonstrate that with the full ANTARES neutrino telescope the design angular resolution of better than 0.3 degrees can be realistically achieved.
  •  
4.
  • Aguilar, J. A., et al. (författare)
  • The data acquisition system for the ANTARES neutrino telescope
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 570:1, s. 107-116
  • Tidskriftsartikel (refereegranskat)abstract
    • The ANTARES neutrino telescope is being constructed in the Mediterranean Sea. It consists of a large three-dimensional array of photo-multiplier tubes. The data acquisition system of the detector takes care of the digitisation of the photo-multiplier tube signals, data transport, data filtering, and data storage. The detector is operated using a control program interfaced with all elements. The design and the implementation of the data acquisition system are described. (c) 2006 Elsevier B.V. All rights reserved.
  •  
5.
  • Clark, Andrew G., et al. (författare)
  • Evolution of genes and genomes on the Drosophila phylogeny
  • 2007
  • Ingår i: Nature. - : Springer Science and Business Media LLC. - 0028-0836 .- 1476-4687. ; 450:7167, s. 203-218
  • Tidskriftsartikel (refereegranskat)abstract
    • Comparative analysis of multiple genomes in a phylogenetic framework dramatically improves the precision and sensitivity of evolutionary inference, producing more robust results than single-genome analyses can provide. The genomes of 12 Drosophila species, ten of which are presented here for the first time (sechellia, simulans, yakuba, erecta, ananassae, persimilis, willistoni, mojavensis, virilis and grimshawi), illustrate how rates and patterns of sequence divergence across taxa can illuminate evolutionary processes on a genomic scale. These genome sequences augment the formidable genetic tools that have made Drosophila melanogaster a pre-eminent model for animal genetics, and will further catalyse fundamental research on mechanisms of development, cell biology, genetics, disease, neurobiology, behaviour, physiology and evolution. Despite remarkable similarities among these Drosophila species, we identified many putatively non-neutral changes in protein-coding genes, non-coding RNA genes, and cis-regulatory regions. These may prove to underlie differences in the ecology and behaviour of these diverse species.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  • Dare, Emma V., et al. (författare)
  • Fibrin Sealants from Fresh or Fresh/Frozen Plasma as Scaffolds for In Vitro Articular Cartilage Regeneration
  • 2009
  • Ingår i: TISSUE ENGINEERING PART A. - : Mary Ann Leibert Inc. - 1937-3341 .- 1937-335X. ; 15:8, s. 2285-2297
  • Tidskriftsartikel (refereegranskat)abstract
    • Our objective was to evaluate human CryoSeal (R) fibrin glue derived from single units of plasma as scaffolds for articular cartilage tissue engineering. Human articular chondrocytes were encapsulated into genipin cross-linked fibrin glue derived from individual units of fresh or frozen plasma using the CryoSeal (R) fibrin sealant (FS) system. The constructs were cultured for up to 7 weeks in vitro under low (5%) or normal (21%) oxygen. Chondrocyte viability was greater than90% within the fibrin gels. Hypoxia induced significant increases in collagen II and Sox9 gene expression and a significant decrease in collagen I. A significant increase in collagen II was detected in fresh plasma-derived cultures, while only collagen I was significantly increased in frozen plasma cultures. Significant increases in total glycosaminoglycan and collagen were detected in the extracellular matrix secreted by the encapsulated chondrocytes. A significant increase in compression modulus was only observed for fresh plasma-derived gels, which is likely explained by a greater amount of collagen type I detected after 7 weeks in frozen compared to fresh plasma gels. Our results indicate that CryoSeal (R) fibrin glue derived from fresh plasma is suitable as a tissue engineering scaffold for human articular chondrocytes, and therefore should be evaluated for autologous articular cartilage regeneration.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-9 av 9

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy