SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ureba Ana) srt2:(2016)"

Sökning: WFRF:(Ureba Ana) > (2016)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Barbeiro, A. R., et al. (författare)
  • 3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry
  • 2016
  • Ingår i: PLOS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 11:11
  • Tidskriftsartikel (refereegranskat)abstract
    • A model based on a specific phantom, called QuAArC, has been designed for the evaluation of planning and verification systems of complex radiotherapy treatments, such as volumetric modulated arc therapy (VMAT). This model uses the high accuracy provided by the Monte Carlo (MC) simulation of log files and allows the experimental feedback from the high spatial resolution of films hosted in QuAArC. This cylindrical phantom was specifically designed to host films rolled at different radial distances able to take into account the entrance fluence and the 3D dose distribution. Ionization chamber measurements are also included in the feedback process for absolute dose considerations. In this way, automated MC simulation of treatment log files is implemented to calculate the actual delivery geometries, while the monitor units are experimentally adjusted to reconstruct the dose-volume histogram (DVH) on the patient CT. Prostate and head and neck clinical cases, previously planned with Monaco and Pinnacle treatment planning systems and verified with two different commercial systems (Delta4 and COMPASS), were selected in order to test operational feasibility of the proposed model. The proper operation of the feedback procedure was proved through the achieved high agreement between reconstructed dose distributions and the film measurements (global gamma passing rates > 90% for the 2%/2 mm criteria). The necessary discretization level of the log file for dose calculation and the potential mismatching between calculated control points and detection grid in the verification process were discussed. Besides the effect of dose calculation accuracy of the analytic algorithm implemented in treatment planning systems for a dynamic technique, it was discussed the importance of the detection density level and its location in VMAT specific phantom to obtain a more reliable DVH in the patient CT. The proposed model also showed enough robustness and efficiency to be considered as a pre-treatment VMAT verification system.
  •  
2.
  • Mondlane, Gracinda, 1987-, et al. (författare)
  • Dosimetric Comparison of Plans for Photon- or Proton-Beam Based Radiosurgery of Liver Metastases
  • 2016
  • Ingår i: International Journal of Particle Therapy. - 2331-5180. ; 3:2, s. 277-284
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Radiosurgery treatment of liver metastases with photon beams has been an established method for more than a decade. One method commonly used is the stereotactic body radiation therapy (SBRT) technique. The aim of this study was to investigate the potential sparing of the organs at risk (OARs) that the use of intensity-modulated proton therapy (IMPT), instead of SBRT, could enable.Patients and Methods: A comparative treatment-planning study of photon-beam and proton-beam based liver-cancer radiosurgery was performed. Ten patients diagnosed with liver metastasis and previously treated with SBRT at the Karolinska University Hospital were included in the study. New IMPT plans were prepared for all patients, while the original plans were set as reference plans. The IMPT planning was performed with the objective of achieving the same target dose coverage as with the SBRT plans. Pairwise dosimetric comparisons of the treatment plans were then performed for the OARs. A 2-sided Wilcoxon signed-rank test with significance level of 5% was carried out.Results: Improved sparing of the OARs was made possible with the IMPT plans. There was a significant decrease of the mean doses delivered to the following risk organs: the nontargeted part of the liver (P = .002), the esophagus (P = .002), the right kidney (P = .008), the spinal cord (P = .004), and the lungs (P = .002). The volume of the liver receiving less than 15 Gy was significantly increased with the IMPT plans (P = .004).Conclusion: The IMPT-based radiosurgery plans provided similar target coverage and significant dose reductions for the OARs compared with the photon-beam based SBRT plans. Further studies including detailed information about varying tissue heterogeneities in the beam path, due to organ motion, are required to evaluate more accurately whether IMPT is preferable for the radiosurgical treatment of liver metastases.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy