Sökning: WFRF:(Vaernesbranden M. R.)
> (2022) >
Fetal Thoracic Circ...
Fetal Thoracic Circumference and Lung Volume and Their Relation to Fetal Size and Pulmonary Artery Blood Flow
-
Hilde, K. (författare)
-
Carlsen, K. C. L. (författare)
-
Bains, K. E. S. (författare)
-
visa fler...
-
Gudmundsdottir, H. K. (författare)
-
Jonassen, C. M. (författare)
-
Kreyberg, I. (författare)
-
LeBlanc, M. (författare)
-
Nordhagen, L. (författare)
-
- Nordlund, B. (författare)
- Karolinska Institutet
-
Rehbinder, E. M. (författare)
-
Sjaborg, K. D. (författare)
-
Skjerven, H. O. (författare)
-
Staff, A. C. (författare)
-
Sundet, B. K. (författare)
-
Vettukattil, R. (författare)
-
Vaernesbranden, M. R. (författare)
-
- Wiik, Johanna (författare)
- Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för obstetrik och gynekologi,Institute of Clinical Sciences, Department of Obstetrics and Gynecology
-
Haugen, G. (författare)
-
visa färre...
-
(creator_code:org_t)
- 2021-07-21
- 2022
- Engelska.
-
Ingår i: Journal of Ultrasound in Medicine. - : Wiley. - 0278-4297 .- 1550-9613. ; 41:4, s. 985-993
- Relaterad länk:
-
https://onlinelibrar...
-
visa fler...
-
https://gup.ub.gu.se...
-
https://doi.org/10.1...
-
http://kipublication...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective Research on early origins of lung disease suggests the need for studying the relationships of thoracic and lung size with fetal size and pulmonary circulation. The primary aim of this study is therefore to explore the associations between fetal thoracic circumference, lung volume, and fetal size. We also aim to assess if lung volume and thoracic circumference are associated with fetal pulmonary artery blood flow velocity measures. Methods Cross-sectional assessment of singleton pregnancies from the general population (n = 447) at 30 gestational weeks (GW) was performed using ultrasound measurement of fetal thoracic circumference, lung volume, head and abdominal circumference, and femur length. We obtained Doppler blood flow velocity measures from the proximal branches of the fetal pulmonary artery. Associations between variables were studied using Pearson's correlation and multiple linear regression analyses. Results Both thoracic circumference and lung volume correlated with fetal size measures, ranging from r = 0.64 between thoracic circumference and abdominal circumference, to r = 0.28 between lung volume and femur length. Adjustment for gestational age, maternal nicotine use, pre-pregnancy body mass index, and fetal sex marginally influenced the associations with abdominal circumference. The correlations of thoracic circumference and lung volume with pulmonary artery blood flow velocity measures were weak (r <= 0.17). Conclusion We found moderate to low correlation between thoracic circumference, lung volume, and fetal size at 30 GW. The closest relationship was with the abdominal circumference. We found low correlations of thoracic circumference and lung volume with pulmonary artery blood flow velocity measures.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine (hsv//eng)
Nyckelord
- Doppler
- fetal
- lung volume
- pulmonary
- artery
- Prevent
- ADALL
- thoracic circumference
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Hilde, K.
-
Carlsen, K. C. L ...
-
Bains, K. E. S.
-
Gudmundsdottir, ...
-
Jonassen, C. M.
-
Kreyberg, I.
-
visa fler...
-
LeBlanc, M.
-
Nordhagen, L.
-
Nordlund, B.
-
Rehbinder, E. M.
-
Sjaborg, K. D.
-
Skjerven, H. O.
-
Staff, A. C.
-
Sundet, B. K.
-
Vettukattil, R.
-
Vaernesbranden, ...
-
Wiik, Johanna
-
Haugen, G.
-
visa färre...
- Om ämnet
-
- MEDICIN OCH HÄLSOVETENSKAP
-
MEDICIN OCH HÄLS ...
-
och Klinisk medicin
- Artiklar i publikationen
-
Journal of Ultra ...
- Av lärosätet
-
Göteborgs universitet
-
Karolinska Institutet