SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Varga O) srt2:(2000-2004)"

Sökning: WFRF:(Varga O) > (2000-2004)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Miliotis, T., et al. (författare)
  • Analysis of regulatory phosphorylation sites in ZAP-70 by capillary high-performance liquid chromatography coupled to electrospray ionization or matrix-assisted laser desorption ionization time-of-flight mass spectrometry
  • 2001
  • Ingår i: Journal of Chromatography. B, Biomedical Sciences and Applications. - : Elsevier BV. - 1387-2273 .- 0378-4347. ; 752:2, s. 323-334
  • Tidskriftsartikel (refereegranskat)abstract
    • A methodology for the rapid and quantitative analysis of phosphorylation sites in proteins is presented. The coupling of capillary high-performance liquid chromatography (HPLC) to electrospray ionization mass spectrometry (ESI-MS) allowed one to distinguish phosphorylation sites based on retention time and mass difference from complex peptide mixtures. The methodology was first evaluated and validated for a mixture of non-, mono-, and dityrosine-phosphorylated synthetic peptides, corresponding to the tryptic fragment 485-496 (ALGADDSYYTAR) of the human protein tyrosine kinase ZAP-70. The limits of detection for the non-, mono- and diphosphorylated peptides were about 15. 40 and 100 fmol, respectively, when using a 300 mum I.D. column. Application of the method was extended to identify phosphopeptides generated from a trypsin digest of recombinant autophosphorylated ZAP-70, in particular with respect to quantifying the status at the regulatory phosphorylation sites Tyr-492 and Tyr-493. Combination of chromatographic and on-line tandem mass spectrometry data, allowed one to ascertain the identity of the detected peptides, a prerequisite to analyses in more complex biological samples. As an extension to the methodology described above, we evaluated the feasibility of interfacing capillary HPLC to matrix assisted laser desorption ionisation time-of-Right mass spectrometry (MALDI-TOF-MS), using a micromachined piezoelectric flow-through dispenser as the interface. This enabled direct arraying of chromatographically separated components onto a target plate that was precoated with matrix for subsequent analysis by MALDI-TOF-MS without further sample handling. (C) 2001 Elsevier Science B.V. All rights reserved.
  •  
2.
  • Wirtz, L., et al. (författare)
  • Curve-Crossing Analysis for Potential Sputtering of Insulators
  • 2000
  • Ingår i: Surface Science. - 0039-6028 .- 1879-2758. ; 451:1-3, s. 197-202
  • Tidskriftsartikel (refereegranskat)abstract
    • We develop a theoretical model for the recently observed threshold for potential sputtering of LiF by slow singly and doubly charged ions. The threshold coincides with the potential energy to create a cold hole in the valence band of LiF by resonant neutralization. We calculate the level shift of the incident ion and the deformation of the valence band under the influence of the projectile. Resonant neutralization becomes possible for ions with recombination energies larger than 10 eV in agreement with the experimental findings.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy