SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wålinder Robert) srt2:(2005-2009)"

Sökning: WFRF:(Wålinder Robert) > (2005-2009)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andréasson, Sara Näslund, et al. (författare)
  • Peritonectomy with high voltage electrocautery generates higher levels of ultrafine smoke particles
  • 2008
  • Ingår i: European Journal of Surgical Oncology. - : Elsevier BV. - 0748-7983 .- 1532-2157. ; 35:7, s. 780-784
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: To adequately perform peritonectomy, the use of an electrocautery device at a high voltage is recommended. The aim of this study was to analyse the amount of airborne and ultrafine particles (UFP) generated during peritonectomy and to compare this with standard colon and rectal cancer surgery (CRC). METHOD: UFP was measured approximately 2-3cm from the breathing area of the surgeon (personal sampling) and 3m from where the electrocautery smoke was generated (stationary sampling) from 14 consecutive peritonectomy procedures and 11 standard CRC resections. The sampling was by P-Trak UFP counter that has the capacity to detect particle size ranging from 0.02 to 1mum. RESULTS: The cumulative level of UFP of personal sampling in the peritonectomy group was higher (9.3x10(6)particle/ml/h (pt/ml/h)) than in the control group (4.8x10(5)pt/ml/h). A higher cumulative level of UFP in stationary sampling was observed in the PC group (2.6x10(6) pt/ml/h) than in the control group (3.9x10(4)pt/ml/h). CONCLUSION: Peritonectomy procedure with high voltage electrocautery generates elevated levels of UFP than standard CRC surgery does. The level of UFP produced by a peritonectomy is comparable to cigarette smoking. More efficient smoke evacuator systems are needed in order to reduce the levels of UFP generated during electrocautery surgery.
  •  
2.
  • Elfman, Lena, et al. (författare)
  • Influence of horse stable environment on human airways
  • 2009
  • Ingår i: Journal of Occupational Medicine and Toxicology. - : Springer Science and Business Media LLC. - 1745-6673. ; 4, s. 10-
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Many people spend considerable amount of time each day in equine stable environments either as employees in the care and training of horses or in leisure activity. However, there are few studies available on how the stable environment affects human airways. This study examined in one horse stable qualitative differences in indoor air during winter and late summer conditions and assessed whether air quality was associated with clinically detectable respiratory signs or alterations to selected biomarkers of inflammation and lung function in stable personnel. METHODS: The horse stable environment and stable-workers (n = 13) in one stable were investigated three times; first in the winter, second in the interjacent late summer and the third time in the following winter stabling period. The stable measurements included levels of ammonia, hydrogen sulphide, total and respirable dust, airborne horse allergen, microorganisms, endotoxin and glucan. The stable-workers completed a questionnaire on respiratory symptoms, underwent nasal lavage with subsequent analysis of inflammation markers, and performed repeated measurements of pulmonary function. RESULTS: Measurements in the horse stable showed low organic dust levels and high horse allergen levels. Increased viable level of fungi in the air indicated a growing source in the stable. Air particle load as well as 1,3-beta-glucan was higher at the two winter time-points, whereas endotoxin levels were higher at the summer time-point. Two stable-workers showed signs of bronchial obstruction with increased PEF-variability, increased inflammation biomarkers relating to reported allergy, cold or smoking and reported partly work-related symptoms. Furthermore, two other stable-workers reported work-related airway symptoms, of which one had doctor's diagnosed asthma which was well treated. CONCLUSION: Biomarkers involved in the development of airway diseases have been studied in relation to environmental exposure levels in equine stables. Respirable dust and 1,3-beta-glucan levels were increased at winter stabling conditions. Some employees (3/13) had signs of bronchial obstruction, which may be aggravated by working in the stable environment. This study contributes to the identification of suitable biomarkers to monitor the indoor horse stable environment and the personnel. An improved management of the stable climate will be beneficial for the health of both stable workers and horses.
  •  
3.
  •  
4.
  • Wålinder, Robert, et al. (författare)
  • Acute effects of 1-octen-3-ol, a microbial volatile organic compound (MVOC)--an experimental study
  • 2008
  • Ingår i: Toxicology Letters. - : Elsevier BV. - 0378-4274 .- 1879-3169. ; 181:3, s. 141-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Acute effects were assessed from exposure to a common volatile compound of microbial origin, the aliphatic alcohol 1-octen 3-ol (octenol). Twenty-nine volunteers performed symptom reports, measurement of blink frequency by electromyography, measurement of the eye break-up time, vital staining of the eye, nasal lavage, acoustic rhinometry, transfer tests and dynamic spirometry. Subjects were during 2h in random order exposed to either 10mg/m(3) of octenol or clean air as control. During octenol exposure subjective ratings of smell and nasal irritation were increased together with higher nasal lavage biomarker levels of eosinophil cationic protein, myeloperoxidase and lysozyme. Also eye irritation and blinking frequency were increased together with throat irritation, mild dyspnoea after 1-h but not after 2-h, and a small decrease in vital capacity. Ratings of headache and nausea were also increased. Atopics did not have more reactions due to exposure, whereas females experienced more smell and mucosal irritation. Thus, there were both subjective and objective signs of mild mucosal irritation of eyes and airways together with symptoms of headache and nausea.
  •  
5.
  • Wålinder, Robert, et al. (författare)
  • Acute effects of a fungal volatile compound
  • 2005
  • Ingår i: Journal of Environmental Health Perspectives. - : Environmental Health Perspectives. - 0091-6765 .- 1552-9924. ; 113:12, s. 1775-1778
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: 3-Methylfuran (3-MF) is a common fungal volatile product with active biologic properties, and previous studies have indicated a contribution to airway disease. The aim of the present study was to assess the acute health effects of this compound in humans. DESIGN: Acute effects were assessed via chamber exposure to (1 mg/m3) 3-MF. PARTICIPANTS AND MEASUREMENTS: Twenty-nine volunteers provided symptom reports, ocular electromyograms, measurement of eye tear film break-up time,vital staining of the eye, nasal lavage, acoustic rhinometry, transfer tests, and dynamic spirometry. RESULTS: No subjective ratings were significantly increased during exposure. Blinking frequency and the lavage biomarkers myeloperoxidase and lysozyme were significantly increased, and forced vital capacity was significantly decreased during exposure to 3-MF compared with air control. CONCLUSIONS AND RELEVANCE TO CLINICAL PRACTICE: Acute effects in the eyes, nose, and airways were detected and might be the result of the biologically active properties of 3-MF. Thus, 3-MF may contribute to building-related illness.
  •  
6.
  • Wålinder, Robert, et al. (författare)
  • Physiological and psychological stress reactions in relation to classroom noise
  • 2007
  • Ingår i: Scandinavian Journal of Work, Environment and Health. - 0355-3140 .- 1795-990X. ; 33:4, s. 260-266
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives This study tested the hypothesis that classroom noise is related to stress reactions among primary school children. Stress was monitored via symptoms of fatigue and headache, systolic blood pressure, reduced diurnal cortisol variation, and indicators of emotional distress. Methods In three classrooms of pupils in the fourth grade (10 years of age), daily measurements of equivalent sound levels (Leq) were made during 4 weeks, evenly distributed from September to December. One day each week of the study, the pupils answered a questionnaire about disturbance and symptoms, and blood pressure and salivary cortisol were measured. In the first and fourth week, the children also performed a standardized drawing test concerning emotional indicators. Results Daily measurements of equivalent sound levels in the classes (Leq during schoolday) ranged from 59 to 87 dB(A). Equivalent sound-levels were significantly related to an increased prevalence of symptoms of fatigue and headache and a reduced diurnal cortisol variability. Blood pressure and emotional indicators were not significantly related to sound levels. Conclusions Current sound levels in Swedish classrooms may have a negative health impact, being directly or indirectly related to stress reactions among children. This finding indicates that noise should be focused on as a risk factor in the school environment.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy