SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Wacker M) srt2:(2010-2014)"

Sökning: WFRF:(Wacker M) > (2010-2014)

  • Resultat 1-12 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Altheimer, A., et al. (författare)
  • Boosted objects and jet substructure at the LHC. Report of BOOST2012, held at IFIC Valencia, 23rd-27th of July 2012
  • 2014
  • Ingår i: European Physical Journal C. Particles and Fields. - : Springer Science and Business Media LLC. - 1434-6044. ; 74:3
  • Tidskriftsartikel (refereegranskat)abstract
    • This report of the BOOST2012 workshop presents the results of four working groups that studied key aspects of jet substructure. We discuss the potential of first-principle QCD calculations to yield a precise description of the substructure of jets and study the accuracy of state-of-the-art Monte Carlo tools. Limitations of the experiments' ability to resolve substructure are evaluated, with a focus on the impact of additional (pile-up) proton proton collisions on jet substructure performance in future LHC operating scenarios. A final section summarizes the lessons learnt from jet substructure analyses in searches for new physics in the production of boosted top quarks.
  •  
2.
  • Abdesselam, A., et al. (författare)
  • Boosted objects : a probe of beyond the standard model physics
  • 2011
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 71:6, s. 1661-
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the report of the hadronic working group of the BOOST2010 workshop held at the University of Oxford in June 2010. The first part contains a review of the potential of hadronic decays of highly boosted particles as an aid for discovery at the LHC and a discussion of the status of tools developed to meet the challenge of reconstructing and isolating these topologies. In the second part, we present new results comparing the performance of jet grooming techniques and top tagging algorithms on a common set of benchmark channels. We also study the sensitivity of jet substructure observables to the uncertainties in Monte Carlo predictions.
  •  
3.
  • Lechner, C., et al. (författare)
  • First direct seeding at 38 nm
  • 2012
  • Ingår i: FEL 2012 - 34th International Free Electron Laser Conference. - 9783954501236 ; , s. 197-199
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The sFLASH project at DESY is an experiment to study direct seeding using a source based on the high-harmonic generation (HHG) process. In contrast to SASE, a seeded FEL exhibits greatly improved longitudinal coherence and higher shot-to-shot stability (both spectral and energetic). In addition, the output of the seeded FEL is intrinsically synchronized to the HHG drive laser, thus enabling pump-probe experiments with a resolution of the order of 10 fs. The installation and successful commissioning of the sFLASH components in 2010/2011 has been followed by a planned upgrade in autumn 2011. As a result of these improvements, in spring 2012 direct HHG seeding at 38 nm has been successfully demonstrated. In this contribution, we describe the experimental layout and announce the first seeding at 38 nm.
  •  
4.
  • Szidat, S., et al. (författare)
  • Intercomparison of 14C Analysis of Carbonaceous Aerosols : Exercise 2009
  • 2013
  • Ingår i: Radiocarbon. - : Cambridge University Press (CUP). - 0033-8222 .- 1945-5755. ; 55:2-3, s. 1496-1509
  • Tidskriftsartikel (refereegranskat)abstract
    • Radiocarbon analysis of the carbonaceous aerosol allows an apportionment of fossil and non-fossil sources of airborne particulate matter (PM). A chemical separation of total carbon (TC) into its subfractions organic carbon (OC) and elemental carbon (EC) refines this powerful technique, as OC and EC originate from different sources and undergo different processes in the atmosphere. Although C-14 analysis of TC, EC, and OC has recently gained increasing attention, interlaboratory quality assurance measures have largely been missing, especially for the isolation of EC and OC. In this work, we present results from an intercomparison of 9 laboratories for C-14 analysis of carbonaceous aerosol samples on quartz fiber filters. Two ambient PM samples and 1 reference material (RM 8785) were provided with representative filter blanks. All laboratories performed C-14 determinations of TC and a subset of isolated EC and OC for isotopic measurement. In general, C-14 measurements of TC and OC agreed acceptably well between the laboratories, i.e. for TC within 0.015-0.025 (FC)-C-14 for the ambient filters and within 0.041 (FC)-C-14 for RM 8785. Due to inhomogeneous filter loading, RM 8785 demonstrated only limited applicability as a reference material for C-14 analysis of carbonaceous aerosols. C-14 analysis of EC revealed a large deviation between the laboratories of 28-79% as a consequence of different separation techniques. This result indicates a need for further discussion on optimal methods of EC isolation for C-14 analysis and a second stage of this intercomparison.
  •  
5.
  • Franckie, Martin, et al. (författare)
  • Comparative analysis of quantum cascade laser modeling based on density matrices and non-equilibrium Green's functions
  • 2014
  • Ingår i: Applied Physics Letters. - : AIP Publishing. - 0003-6951 .- 1077-3118. ; 105:10
  • Tidskriftsartikel (refereegranskat)abstract
    • We study the operation of an 8.5 mu m quantum cascade laser based on GaInAs/AlInAs lattice matched to InP using three different simulation models based on density matrix (DM) and non-equilibrium Green's function (NEGF) formulations. The latter advanced scheme serves as a validation for the simpler DM schemes and, at the same time, provides additional insight, such as the temperatures of the sub-band carrier distributions. We find that for the particular quantum cascade laser studied here, the behavior is well described by simple quantum mechanical estimates based on Fermi's golden rule. As a consequence, the DM model, which includes second order currents, agrees well with the NEGF results. Both these simulations are in accordance with previously reported data and a second regrown device. (C) 2014 AIP Publishing LLC.
  •  
6.
  • Franckie, Martin, et al. (författare)
  • Injection schemes in THz quantum cascade lasers under operation
  • 2013
  • Ingår i: Proceedings of SPIE. - : SPIE. - 9780819496966 ; 8846
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • The two main design schemes for Terahertz quantum cascade lasers, based on tunnelling and scattering injection, respectively, are theoretically compared. We apply our simulation package based on the non-equilibrium Green’s function technique. Our results provide a good description of the gain degradation with temperature. Thermal backfilling contributes to decrease of population inversion in both cases. However, the dropping inversion cannot account for the total reduction of gain.
  •  
7.
  • Hoogendoorn, Martine, et al. (författare)
  • Cost-Effectiveness Models for Chronic Obstructive Pulmonary Disease: Cross-Model Comparison of Hypothetical Treatment Scenarios
  • 2014
  • Ingår i: Value in Health. - : Elsevier BV. - 1098-3015. ; 17:5, s. 525-536
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To compare different chronic obstructive pulmonary disease (COPD) cost-effectiveness models with respect to structure and input parameters and to cross-validate the models by running the same hypothetical treatment scenarios. Methods COPD modeling groups simulated four hypothetical interventions with their model and compared the results with a reference scenario of no intervention. The four interventions modeled assumed 1) 20% reduction in decline in lung function, 2) 25% reduction in exacerbation frequency, 3) 10% reduction in all-cause mortality, and 4) all these effects combined. The interventions were simulated for a 5-year and lifetime horizon with standardization, if possible, for sex, age, COPD severity, smoking status, exacerbation frequencies, mortality due to other causes, utilities, costs, and discount rates. Furthermore, uncertainty around the outcomes of intervention four was compared. Results Seven out of nine contacted COPD modeling groups agreed to participate. The 5-year incremental cost-effectiveness ratios (ICERs) for the most comprehensive intervention, intervention four, was €17,000/quality-adjusted life-year (QALY) for two models, €25,000 to €28,000/QALY for three models, and €47,000/QALY for the remaining two models. Differences in the ICERs could mainly be explained by differences in input values for disease progression, exacerbation-related mortality, and all-cause mortality, with high input values resulting in low ICERs and vice versa. Lifetime results were mainly affected by the input values for mortality. The probability of intervention four to be cost-effective at a willingness-to-pay value of €50,000/QALY was 90% to 100% for five models and about 70% and 50% for the other two models, respectively. Conclusions Mortality was the most important factor determining the differences in cost-effectiveness outcomes between models.
  •  
8.
  • Liu, Wei, et al. (författare)
  • Serial Femtosecond Crystallography of G Protein-Coupled Receptors
  • 2013
  • Ingår i: Science. - : American Association for the Advancement of Science (AAAS). - 0036-8075 .- 1095-9203. ; 342:6165, s. 1521-1524
  • Tidskriftsartikel (refereegranskat)abstract
    • X-ray crystallography of G protein-coupled receptors and other membrane proteins is hampered by difficulties associated with growing sufficiently large crystals that withstand radiation damage and yield high-resolution data at synchrotron sources. We used an x-ray free-electron laser (XFEL) with individual 50-femtosecond-duration x-ray pulses to minimize radiation damage and obtained a high-resolution room-temperature structure of a human serotonin receptor using sub-10-micrometer microcrystals grown in a membrane mimetic matrix known as lipidic cubic phase. Compared with the structure solved by using traditional microcrystallography from cryo-cooled crystals of about two orders of magnitude larger volume, the room-temperature XFEL structure displays a distinct distribution of thermal motions and conformations of residues that likely more accurately represent the receptor structure and dynamics in a cellular environment.
  •  
9.
  • Nilsson, Henrik, et al. (författare)
  • Correlation-induced conductance suppression at level degeneracy in a quantum dot.
  • 2010
  • Ingår i: Physical Review Letters. - 1079-7114. ; 104:18
  • Tidskriftsartikel (refereegranskat)abstract
    • The large, level-dependent g factors in an InSb nanowire quantum dot allow for the occurrence of a variety of level crossings in the dot. While we observe the standard conductance enhancement in the Coulomb blockade region for aligned levels with different spins due to the Kondo effect, a vanishing of the conductance is found at the alignment of levels with equal spins. This conductance suppression appears as a canyon cutting through the web of direct tunneling lines and an enclosed Coulomb blockade region. In the center of the Coulomb blockade region, we observe the predicted correlation-induced resonance. Our findings are supported by numerical and analytical calculations.
  •  
10.
  • Schwitter, Juerg, et al. (författare)
  • MR-IMPACT II: Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial : perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial
  • 2013
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 34:10, s. 775-781
  • Tidskriftsartikel (refereegranskat)abstract
    • AimsPerfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard.Methods and resultsIn this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients.ConclusionIn this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.
  •  
11.
  • Schwitter, Juerg, et al. (författare)
  • Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease : The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial).
  • 2012
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - 1097-6647 .- 1532-429X. ; 14:1, s. 61-
  • Tidskriftsartikel (refereegranskat)abstract
    • ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.
  •  
12.
  • Weierstall, Uwe, et al. (författare)
  • Lipidic cubic phase injector facilitates membrane protein serial femtosecond crystallography
  • 2014
  • Ingår i: Nature Communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 5, s. 3309-
  • Tidskriftsartikel (refereegranskat)abstract
    • Lipidic cubic phase (LCP) crystallization has proven successful for high-resolution structure determination of challenging membrane proteins. Here we present a technique for extruding gel-like LCP with embedded membrane protein microcrystals, providing a continuously renewed source of material for serial femtosecond crystallography. Data collected from sub-10-mu m-sized crystals produced with less than 0.5 mg of purified protein yield structural insights regarding cyclopamine binding to the Smoothened receptor.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-12 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy