SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Ylitalo Antti) srt2:(2013)"

Sökning: WFRF:(Ylitalo Antti) > (2013)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Kosonen, Petteri, et al. (författare)
  • Intravascular ultrasound assessed incomplete stent apposition and stent fracture in stent thrombosis after bare metal versus drug-eluting stent treatment the Nordic Intravascular Ultrasound Study (NIVUS)
  • 2013
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273. ; 168:2, s. 1010-1016
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: This prospective multicenter registry used intravascular ultrasound (IVUS) in patients with definite stent thrombosis (ST) to compare rates of incomplete stent apposition (ISA), stent fracture and stent expansion in patients treated with drug-eluting (DES) versus bare metal (BMS) stents. ST is a rare, but potential life threatening event after coronary stent implantation. The etiology seems to be multifactorial. Methods: 124 patients with definite ST were assessed by IVUS during the acute ST event. The study was conducted in 15 high-volume percutaneous coronary intervention -centers in the Nordic-Baltic countries. Results: In early or late ST there were no differences in ISA between DES and BMS. In very late ST, ISA was a more frequent finding in DES than in BMS (52% vs. 16%; p=0.005) and the maximum ISA area was larger in DES compared to BMS(1.1 +/- 2.3 mm(2) vs. 0.1 +/- 0.5 mm(2); p=0.004). Further, ISA was more prevalent in sirolimus-eluting than in paclitaxel-eluting stents (58% vs. 37%; p-0.02). Stent fractures were found both in DES (16%) and BMS (24%); p=0.28, and not related to time of stent thrombosis occurrence. For stents with nominal diameters >= 2.75 mm, 38% of the DES and 22% of the BMS had a minimum stent area of less than 5 mm(2); p=0.14. Conclusions: Very late stent thrombosis was more prevalent and associated with more extensive ISA in DES than in BMS treated patients. Stent fracture was a common finding in ST after DES and BMS implantation. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
  •  
2.
  • Maeng, Michael, et al. (författare)
  • Long-Term Results After Simple Versus Complex Stenting of Coronary Artery Bifurcation Lesions : Nordic Bifurcation Study 5-Year Follow-Up Results
  • 2013
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097 .- 1558-3597. ; 62:1, s. 30-34
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives This study sought to report the 5-year follow-up results of the Nordic Bifurcation Study. Background Randomized clinical trials with short-term follow-up have indicated that coronary bifurcation lesions may be optimally treated using the optional side branch stenting strategy. Methods A total of 413 patients with a coronary bifurcation lesion were randomly assigned to a simple stenting strategy of main vessel (MV) and optional stenting of side branch (SB) or to a complex stenting strategy, namely, stenting of both MV and SB. Results Five-year clinical follow-up data were available for 404 (98%) patients. The combined safety and efficacy endpoint of cardiac death, non-procedure-related myocardial infarction, and target vessel revascularization were seen in 15.8% in the optional SB stenting group as compared to 21.8% in the MV and SB stenting group (p = 0.15). All-cause death was seen in 5.9% versus 10.4% (p = 0.16) and non-procedure-related myocardial infarction in 4% versus 7.9% (p = 0.09) in the optional SB stenting group versus the MV and SB stenting group, respectively. The rates of target vessel revascularization were 13.4% versus 18.3% (p = 0.14) and the rates of definite stent thrombosis were 3% versus 1.5% (p = 0.31) in the optional SB stenting group versus the MV and SB stenting group, respectively. Conclusions At 5-year follow-up in the Nordic Bifurcation Study, the clinical outcomes after simple optional side branch stenting remained at least equal to the more complex strategy of planned stenting of both the main vessel and the side branch. 
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy