SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(van der Meulen Peter) srt2:(2020-2024)"

Sökning: WFRF:(van der Meulen Peter) > (2020-2024)

  • Resultat 1-11 av 11
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Marin, Ida, et al. (författare)
  • Establishment of a clinical SPECT/CT protocol for imaging of(161)Tb
  • 2020
  • Ingår i: Ejnmmi Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background It has been proposed, and preclinically demonstrated, that(161)Tb is a better alternative to(177)Lu for the treatment of small prostate cancer lesions due to its high emission of low-energy electrons.Tb-161 also emits photons suitable for single-photon emission computed tomography (SPECT) imaging. This study aims to establish a SPECT protocol for(161)Tb imaging in the clinic. Materials and methods Optimal settings using various gamma-camera collimators and energy windows were explored by imaging a Jaszczak phantom, including hollow-sphere inserts, filled with(161)Tb. The collimators examined were extended low-energy general purpose (ELEGP), medium-energy general purpose (MEGP), and low-energy high resolution (LEHR), respectively. In addition, three ordered subset expectation maximization (OSEM) algorithms were investigated: attenuation-corrected OSEM (A-OSEM); attenuation and dual- or triple-energy window scatter-corrected OSEM (AS-OSEM); and attenuation, scatter, and collimator-detector response-corrected OSEM (ASC-OSEM), where the latter utilized Monte Carlo-based reconstruction. Uniformity corrections, using intrinsic and extrinsic correction maps, were also investigated. Image quality was assessed by estimated recovery coefficients (RC), noise, and signal-to-noise ratio (SNR). Sensitivity was determined using a circular flat phantom. Results The best RC and SNR were obtained at an energy window between 67.1 and 82.1 keV. Ring artifacts, caused by non-uniformity, were removed with extrinsic uniformity correction for the energy window between 67.1 and 82.1 keV, but not with intrinsic correction. Analyzing the lower energy window between 48.9 and 62.9 keV, the ring artifacts remained after uniformity corrections. The recovery was similar for the different collimators when using a specific OSEM reconstruction. Recovery and SNR were highest for ASC-OSEM, followed by AS-OSEM and A-OSEM. When using the optimized parameter setting, the resolution of(161)Tb was higher than for(177)Lu (8.4 +/- 0.7 vs. 10.4 +/- 0.6 mm, respectively). The sensitivities for(161)Tb and(177)Lu were 7.41 and 8.46 cps/MBq, respectively. Conclusion SPECT with high resolution is feasible with(161)Tb; however, extrinsic uniformity correction is recommended to avoid ring artifacts. The LEHR collimator was the best choice of the three tested to obtain a high-resolution image. Due to the complex emission spectrum of low-energy photons, window-based scatter correction had a minor impact on the image quality compared to using attenuation correction only. On the other hand, performing attenuation, scatter, and collimator-detector correction clearly improved image quality. Based on these data, SPECT-based dosimetry for(161)Tb-labeled radiopharmaceuticals is feasible.
  •  
2.
  •  
3.
  • Baum, R. P., et al. (författare)
  • First-in-Humans Application of Tb-161: A Feasibility Study Using Tb-161-DOTATOC
  • 2021
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 2159-662X. ; 62:10, s. 1391-1397
  • Tidskriftsartikel (refereegranskat)abstract
    • Tb-161 has decay properties similar to those of Lu-177 but, additionally, emits a substantial number of conversion and Auger electrons. The aim of this study was to apply Tb-161 in a clinical setting and to investigate the feasibility of visualizing the physiologic and tumor biodistributions of Tb-161-DOTATOC. Methods: Tb-161 was shipped from Paul Scherrer Institute, Villigen-PSI, Switzerland, to Zentralklinik Bad Berka, Bad Berka, Germany, where it was used for the radiolabeling of DOTATOC. In 2 separate studies, 596 and 1,300 MBq of Tb-161-DOTATOC were administered to a 35-y-old male patient with a metastatic, well-differentiated, nonfunctional malignant paraganglioma and a 70-y-old male patient with a metastatic, functional neuroendocrine neoplasm of the pancreatic tail, respectively. Whole-body planar g-scintigraphy images were acquired over a period of several days for dosimetry calculations. SPECT/CT images were reconstructed using a recently established protocol and visually analyzed. Patients were observed for adverse events after the application of Tb-161-DOTATOC. Results: The radiolabeling of DOTATOC with Tb-161 was readily achieved with a high radiochemical purity suitable for patient application. Planar images and dosimetry provided the expected time-dependent biodistribution of Tb-161-DOTATOC in the liver, kidneys, spleen, and urinary bladder. SPECT/CT images were of high quality and visualized even small metastases in bones and liver. The application of Tb-161-DOTATOC was well tolerated, and no related adverse events were reported. Conclusion: This study demonstrated the feasibility of imaging even small metastases after the injection of relatively low activities of Tb-161-DOTATOC using g-scintigraphy and SPECT/CT. On the basis of this essential first step in translating Tb-161 to clinics, further efforts will be directed toward the application of Tb-161 for therapeutic purposes.
  •  
4.
  • Bernhardt, Peter, 1966, et al. (författare)
  • Dosimetric analysis of the short-ranged particle emitter161 tb for radionuclide therapy of metastatic prostate cancer
  • 2021
  • Ingår i: Cancers. - : MDPI AG. - 2072-6694. ; 13:9
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this study was to analyze the required absorbed doses to detectable metastases (Dreq ) when using radionuclides with prostate specific membrane antigen (PSMA)-targeting radioligands to achieve a high probability for metastatic control. The Monte Carlo based analysis was performed for the clinically-used radionuclides yttrium-90, iodine-131, lutetium-177, and actinium-225, and the newly-proposed low-energy electron emitter terbium-161. It was demonstrated that metastatic formation rate highly influenced the metastatic distribution. Lower values generated few large detectable metastases, as in the case with oligo metastases, while high values generated a distribution of multiple small detectable metastases, as observed in patients with diffused visualized metastases. With equal number of detectable metastases, the total metastatic volume burden was 4–6 times higher in the oligo metastatic scenario compared to the diffusely visualized scenario. The Dreq was around 30% higher for the situations with 20 detectable metastases compared to one detectable metastasis. The Dreq for iodine-131 and yttrium-90 was high (920–3300 Gy). The Dreq for lutetium-177 was between 560 and 780 Gy and considerably lower Dreq were obtained for actinium-225 and terbium-161, with 240–330 Gy and 210–280 Gy, respectively. In conclusion, the simulations demonstrated that terbium-161 has the potential for being a more effective targeted radionuclide therapy for metastases using PSMA ligands. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
  •  
5.
  • Busslinger, Sarah D., et al. (författare)
  • Comparison of the tolerability of 161Tb- and 177Lu-labeled somatostatin analogues in the preclinical setting
  • 2024
  • Ingår i: EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING. - 1619-7070 .- 1619-7089.
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose [Lu-177]Lu-DOTATATE is an established somatostatin receptor (SSTR) agonist for the treatment of metastasized neuroendocrine neoplasms, while the SSTR antagonist [Lu-177]Lu-DOTA-LM3 has only scarcely been employed in clinics. Impressive preclinical data obtained with [Tb-161]Tb-DOTA-LM3 in tumor-bearing mice indicated the potential of terbium-161 as an alternative to lutetium-177. The aim of the present study was to compare the tolerability of Tb-161- and Lu-177-based DOTA-LM3 and DOTATATE in immunocompetent mice. Methods Dosimetry calculations were performed based on biodistribution data of the radiopeptides in immunocompetent mice. Treatment-related effects on blood cell counts were assessed on Days 10, 28 and 56 after application of [Tb-161]Tb-DOTA-LM3 or [Tb-161]Tb-DOTATATE at 20 MBq per mouse. These radiopeptides were also applied at 100 MBq per mouse and the effects compared to those observed after application of the Lu-177-labeled counterparts. Bone marrow smears, blood plasma parameters and organ histology were assessed at the end of the study. Results The absorbed organ dose was commonly higher for the SSTR antagonist than for the SSTR agonist and for terbium-161 over lutetium-177. Application of a therapeutic activity level of 20 MBq [Tb-161]Tb-DOTA-LM3 or [Tb-161]Tb-DOTATATE was well tolerated without major hematological changes. The injection of 100 MBq of the Tb-161- and Lu-177-based somatostatin analogues affected the blood cell counts, however. The lymphocytes were 40-50% lower in treated mice compared to the untreated controls on Day 10 irrespective of the radionuclide employed. At the same timepoint, thrombocyte and erythrocyte counts were 30-50% and 6-12% lower, respectively, after administration of the SSTR antagonist (p < 0.05) while changes were less pronounced in mice injected with the SSTR agonist. All blood cell counts were in the normal range on Day 56. Histological analyses revealed minimal abnormalities in the kidneys, liver and spleen of treated mice. No correlation was observed between the organ dose and frequency of the occurrence of abnormalities. Conclusion Hematologic changes were more pronounced in mice treated with the SSTR antagonist than in those treated with the SSTR agonist. Despite the increased absorbed dose delivered by terbium-161 over lutetium-177, [Tb-161]Tb-DOTA-LM3 and [Tb-161]Tb-DOTATATE should be safe at activity levels that are recommended for their respective Lu-177-based analogues.
  •  
6.
  •  
7.
  • Gugushvili, Shota, et al. (författare)
  • Nonparametric Bayesian estimation of a Hölder continuous diffusion coefficient
  • 2020
  • Ingår i: Brazilian Journal of Probability and Statistics. - 0103-0752. ; 34:3, s. 537-579
  • Tidskriftsartikel (refereegranskat)abstract
    • We consider a nonparametric Bayesian approach to estimate the diffusion coefficient of a stochastic differential equation given discrete time observations over a fixed time interval. As a prior on the diffusion coefficient, we employ a histogram-type prior with piecewise constant realisations on bins forming a partition of the time interval. Specifically, these constants are realizations of independent inverse Gamma distributed randoma variables. We justify our approach by deriving the rate at which the corresponding posterior distribution asymptotically concentrates around the data-generating diffusion coefficient. This posterior contraction rate turns out to be optimal for estimation of a Hölder-continuous diffusion coefficient with smoothness parameter 0<λ≤1. Our approach is straightforward to implement, as the posterior distributions turn out to be inverse Gamma again, and leads to good practical results in a wide range of simulation examples. Finally, we apply our method on exchange rate data sets.
  •  
8.
  • Hemmingsson, Jens, 1986, et al. (författare)
  • Active bone marrow S-values for the low-energy electron emitter terbium-161 compared to S-values for lutetium-177 and yttrium-90.
  • 2022
  • Ingår i: EJNMMI physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 9:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Based on theoretical and preclinical results, terbium-161 may be a valid alternative to lutetium-177 and yttrium-90 in radionuclide therapies. The large low-energy electron emission from terbium-161 is a favorable feature in the treatment of disseminated disease, but its impact on the radiosensitive bone marrow needs to be evaluated. Using voxel-based skeletal dosimetry models in which active bone marrow is defined as regions containing stem cells and progenitor cells of the hematopoietic lineage, we generated S-values (absorbed dose per decay) for terbium-161 and evaluated its distribution-dependence in bone marrow cavities.S-values in the active bone marrow were calculated for terbium-161, lutetium-177, and yttrium-90 irradiation using two (male/female) image-based bone marrow dosimetry models. The radionuclides were distributed to one of the three structures that define the spongiosa bone region in the skeletal models: (i) active bone marrow, (ii) inactive bone marrow, or (iii) surface or whole volume of the trabecular bone. Decay data from ICRP 107 were combined with specific absorbed fractions to calculate S-values for 13 skeletal sites. To increase the utility, the skeletal site-specific S-values were averaged to produce whole-body average S-values and spongiosa average S-values.For yttrium-90, the high-energy β particles irradiate the active marrow regardless of the source compartment, consistently generating the highest S-values (65-90% higher). Between terbium-161 and lutetium-177, the largest differences in S-values were with an active marrow source (50%), such as self-irradiation, due to the contribution of the short-ranged conversion and Auger electrons from terbium-161. Their influence decreased as the source moved to inactive marrow or the surface or volume of the trabecular bone, reducing the S-values and the differences between terbium-161 and lutetium-177 (15-35%).The S-values of terbium-161 for active bone marrow and, consequently, the bone marrow toxicity profile were more dependent on the radionuclide distribution within the bone marrow cavity than the S-values of lutetium-177 and yttrium-90. This effect was attributed to the considerable low-energy electron emission of terbium-161. Therefore, it will be critical to investigate the bone marrow distribution of a particular radiopharmaceutical for accurate estimation of the active bone marrow dose.
  •  
9.
  •  
10.
  • Tschan, Viviane J., et al. (författare)
  • Albumin-Binding and Conventional PSMA Ligands in Combination with 161Tb: Biodistribution, Dosimetry, and Preclinical Therapy
  • 2023
  • Ingår i: JOURNAL OF NUCLEAR MEDICINE. - 0161-5505 .- 1535-5667. ; 64:10, s. 1625-1631
  • Tidskriftsartikel (refereegranskat)abstract
    • The favorable decay characteristics of 161Tb attracted the interest of clinicians in using this novel radionuclide for radioligand therapy (RLT). 161Tb decays with a similar half-life to 177Lu, but beyond the emission of b2-particles and g-rays, 161Tb also emits conversion and Auger electrons, which may be particularly effective to eliminate micrometastases. The aim of this study was to compare the dosimetry and therapeutic efficacy of 161Tb and 177Lu in tumor-bearing mice using SibuDAB and PSMA-I&T, which differ in their blood residence time and tumor uptake. Methods: [161Tb]Tb-SibuDAB and [161Tb]Tb-PSMA-I&T were evaluated in vitro and investigated in biodistribution, imaging, and therapy studies using PC-3 PIP tumor-bearing mice. The 177Lu-labeled counterparts served for dose calculations and comparison of therapeutic efficacy. The tolerability of RLT in mice was monitored on the basis of body mass, blood plasma parameters, blood cell counts, and the histology of relevant organs and tissues. Results: The prostate-specific membrane antigen (PSMA)-targeting radioligands, irrespective of whether labeled with 161Tb or 177Lu, showed similar in vitro data and comparable tissue distribution profiles. As a result of the albuminbinding properties, [161Tb]Tb/[177Lu]Lu-SibuDAB had an enhanced blood residence time and higher tumor uptake (62%-69% injected activity per gram at 24 h after injection) than [161Tb]Tb/[177Lu]LuPSMA-I&T (30%-35% injected activity per gram at 24 h after injection). [161Tb]Tb-SibuDAB inhibited tumor growth more effectively than [161Tb]Tb-PSMA-I&T, as can be ascribed to its 4-fold increased absorbed tumor dose. At any of the applied activities, the 161Tb-based radioligands were therapeutically more effective than their 177Lulabeled counterparts, as agreed with the approximately 40% increased tumor dose of 161Tb compared with that of 177Lu. Under the given experimental conditions, no obvious adverse events were observed. Conclusion: The data of this study indicate the promising potential of 161Tb in combination with SibuDAB for RLT of prostate cancer. Future clinical studies using 161Tb-based RLT will shed light on a potential clinical benefit of 161Tb over 177Lu.
  •  
11.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-11 av 11

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy