SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(von Heideken J) srt2:(2015-2019)"

Sökning: WFRF:(von Heideken J) > (2015-2019)

  • Resultat 1-10 av 10
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Flinck, M., et al. (författare)
  • Biomechanical comparison of semi-rigid pediatric locking nail versus titanium elastic nails in a femur fracture model
  • 2015
  • Ingår i: Journal of Children's Orthopaedics. - : SAGE Publications. - 1863-2521 .- 1863-2548. ; 9:1, s. 77-84
  • Tidskriftsartikel (refereegranskat)abstract
    • Methods: Twenty-four femur models with an intramedullary canal diameter of 10.0 mm were used. Three groups with various combinations of titanium elastic nails (TEN) with end caps and one group with a PLN were tested. An oblique midshaft fracture was created, and the models underwent compression, rotation, flexion/extension, and a varus/valgus test, with 50 and 100 % of the forces generated during walking in corresponding planes. Results: We present the results [median (range)] from 100 % loading during walking. In axial compression, the PLN was less shortened than the combination with two 4.0-mm TEN [by 4.4 (3.4–5.4) mm vs. 5.2 (4.8–6.6) mm, respectively; p = 0.030]. No difference was found in shortening between the PLN and the four 3.0-mm TEN [by 7.0 (3.3–8.4) mm; p = 0.065]. The two 3.0-mm TEN did not withstand the maximum shortening of 10.0 mm. In external rotation, the PLN rotated 12.0° (7.0–16.4°) while the TEN models displaced more than the maximum of 20.0°. No model withstood a maximal rotation of 20.0° internal rotation. In the four-point bending test, in the coronal and the sagittal plane, all combinations except the two 3.0-mm TEN in extension withstood the maximum angulation of 20.0°. Conclusions: PLN provides the greatest stability in all planes compared to TEN models with end caps, even though the difference from the two 4.0-mm or four 3.0-mm TEN models was small. Background: The treatment for length-unstable diaphyseal femur fractures among school-age children is commonly intramedullary elastic nails, with or without end caps. Another possible treatment is the semi-rigid pediatric locking nail (PLN). The purpose of this biomechanical study was to assess the stability of a length-unstable oblique midshaft fracture in a synthetic femur model stabilized with different combinations of intramedullary elastic nails and with a PLN.
  •  
3.
  •  
4.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • von Heideken, J, et al. (författare)
  • Rapidly increasing incidence in scoliosis surgery over 14 years in a nationwide sample
  • 2018
  • Ingår i: European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. - : Springer Science and Business Media LLC. - 1432-0932. ; 27:2, s. 286-292
  • Tidskriftsartikel (refereegranskat)
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy