1.
  • Nordlund, David, et al. (författare)
  • Multi-vendor, multicentre comparison of contrast-enhanced SSFP and T2-STIR CMR for determining myocardium at risk in ST-elevation myocardial infarction
  • 2016
  • Ingår i: European Heart Journal-Cardiovascular Imaging. - : Oxford University Press (OUP). - 2047-2412 .- 2047-2404. ; 17:7, s. 744-753
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Myocardial salvage, determined by cardiac magnetic resonance imaging (CMR), is used as end point in cardioprotection trials. To calculate myocardial salvage, infarct size is related to myocardium at risk (MaR), which can be assessed by T2-short tau inversion recovery (T2-STIR) and contrast-enhanced steady-state free precession magnetic resonance imaging (CE-SSFP). We aimed to determine how T2-STIR and CE-SSFP perform in determining MaR when applied in multicentre, multi-vendor settings.METHODS AND RESULTS: A total of 215 patients from 17 centres were included after percutaneous coronary intervention (PCI) for ST-elevation myocardial infarction. CMR was performed within 1-8 days. These patients participated in the MITOCARE or CHILL-MI cardioprotection trials. Additionally, 8 patients from a previous study, imaged 1 day post-CMR, were included. Late gadolinium enhancement, T2-STIR, and CE-SSFP images were acquired on 1.5T MR scanners (Philips, Siemens, or GE). In 65% of the patients, T2-STIR was of diagnostic quality compared with 97% for CE-SSFP. In diagnostic quality images, there was no difference in MaR by T2-STIR and CE-SSFP (bias: 0.02 ± 6%, P = 0.96, r(2) = 0.71, P < 0.001), or between treatment and control arms. No change in size or quality of MaR nor ability to identify culprit artery was seen over the first week after the acute event (P = 0.44).CONCLUSION: In diagnostic quality images, T2-STIR and CE-SSFP provide similar estimates of MaR, were constant over the first week, and were not affected by treatment. CE-SSFP had a higher degree of diagnostic quality images compared with T2 imaging for sequences from two out of three vendors. Therefore, CE-SSFP is currently more suitable for implementation in multicentre, multi-vendor clinical trials.
  •  
2.
  • Bhat, Misha, et al. (författare)
  • Fetal iGRASP cine CMR assisting in prenatal diagnosis of complicated cardiac malformation with impact on delivery planning
  • 2019
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 39:4, s. 231-235
  • Tidskriftsartikel (refereegranskat)abstract
    • Limited visualisation of the fetal heart and vessels by fetal ultrasound due to suboptimal fetal position, patient habitus and skeletal calcification may lead to missed diagnosis, overdiagnosis and parental uncertainty. Counseling and delivery planning may in those cases also be tentative. The recent fetal cardiac magnetic resonance (CMR) reconstruction method utilising tiny golden angle iGRASP (iterative Golden-angle RAdial Sparse Parallel MRI) allows for cine imaging of the fetal heart for use in clinical practice. This case describes an unbalanced common atrioventricular canal where limited ultrasound image quality and visibility of the aortic arch precluded confirming or ruling out presence of a ventricular septal defect. Need of prostaglandins or neonatal intervention was thus uncertain. Cardiovascular magnetic resonance imaging confirmed ultrasound findings and added value by ruling out a significant ventricular septal defect and diagnosing arch hypoplasia. This confirmed the need of patient relocation for delivery at a paediatric cardiothoracic surgery centre and prostaglandins could be initiated before the standard postnatal ultrasound. The applied CMR method can thus improve diagnosis of complicated fetal cardiac malformation and has direct clinical impact. This article is protected by copyright. All rights reserved.
  •  
3.
  • Bidhult, Sebastian, et al. (författare)
  • A new vessel segmentation algorithm for robust blood flow quantification from two-dimensional phase-contrast magnetic resonance images
  • 2019
  • Ingår i: Clinical Physiology and Functional Imaging. - : Wiley. - 1475-0961 .- 1475-097X. ; 39:5, s. 327-338
  • Tidskriftsartikel (refereegranskat)abstract
    • Blood flow measurements in the ascending aorta and pulmonary artery from phase-contrast magnetic resonance images require accurate time-resolved vessel segmentation over the cardiac cycle. Current semi-automatic segmentation methods often involve time consuming manual correction, relying on user experience for accurate results. The purpose of this study was to develop a semi-automatic vessel segmentation algorithm with shape constraints based on manual vessel delineations for robust segmentation of the ascending aorta and pulmonary artery, to evaluate the proposed method in healthy volunteers and patients with heart failure and congenital heart disease, to validate the method in a pulsatile flow phantom experiment, and to make the method freely available for research purposes. Algorithm shape constraints were extracted from manual reference delineations of the ascending aorta (n=20) and pulmonary artery (n=20) and were included into a semi-automatic segmentation method only requiring manual delineation in one image. Bias and variability (bias±SD) for flow volume of the proposed algorithm versus manual reference delineations were 0·0±1·9ml in the ascending aorta (n=151; 7 healthy volunteers; 144 heart failure patients) and -1·7±2·9 ml in the pulmonary artery (n=40; 25 healthy volunteers; 15 patients with atrial septal defect). Inter-observer bias and variability were lower (p=0·008) for the proposed semi-automatic method (-0·1±0·9ml) compared to manual reference delineations (1·5±5·1ml). Phantom validation showed good agreement between the proposed method and timer-and-beaker flow volumes (0·4±2·7ml). In conclusion, the proposed semi-automatic vessel segmentation algorithm can be used for efficient analysis of flow and shunt volumes in the aorta and pulmonary artery. This article is protected by copyright. All rights reserved.
  •  
4.
  • Bidhult, Sebastian, et al. (författare)
  • Independent validation of metric optimized gating for fetal cardiovascular phase-contrast flow imaging
  • 2019
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 81:1, s. 495-503
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To validate metric optimized gating phase-contrast MR (MOG PC-MR) flow measurements for a range of fetal flow velocities in phantom experiments. 2) To investigate intra- and interobserver variability for fetal flow measurements at an imaging center other than the original site.METHODS: MOG PC-MR was compared to timer/beaker measurements in a pulsatile flow phantom using a heart rate (∼145 bpm), nozzle diameter (∼6 mm), and flow range (∼130-700 mL/min) similar to fetal imaging. Fifteen healthy fetuses were included for intra- and interobserver variability in the fetal descending aorta and umbilical vein.RESULTS: Phantom MOG PC-MR flow bias and variability was 2% ± 23%. Accuracy of MOG PC-MR was degraded for flow profiles with low velocity-to-noise ratio. Intra- and interobserver coefficients of variation were 6% and 19%, respectively, for fetal descending aorta; and 10% and 17%, respectively, for the umbilical vein.CONCLUSION: Phantom validation showed good agreement between MOG and conventionally gated PC-MR, except for cases with low velocity-to-noise ratio, which resulted in MOG misgating and underestimated peak velocities and warranted optimization of sequence parameters to individual fetal vessels. Inter- and intraobserver variability for fetal MOG PC-MR imaging were comparable to previously reported values.
  •  
5.
  •  
6.
  •  
7.
  • Bidhult, Sebastian, et al. (författare)
  • Validation of T1 and T2 algorithms for quantitative MRI : Performance by a vendor-independent software
  • 2016
  • Ingår i: BMC Medical Imaging. - : Springer Science and Business Media LLC. - 1471-2342. ; 16:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Determination of the relaxation time constants T1 and T2 with quantitative magnetic resonance imaging is increasingly used for both research and clinical practice. Recently, groups have been formed within the Society of Cardiovascular Magnetic Resonance to address issues with relaxometry. However, so far they have avoided specific recommendations on methodology due to lack of consensus and current evolving research. Standardised widely available software may simplify this process. The purpose of the current study was to develop and validate vendor-independent T1 and T2 mapping modules and implement those in the versatile and widespread software Segment, freely available for research and FDA approved for clinical applications. Results: The T1 and T2 mapping modules were developed and validated in phantoms at 1.5T and 3T with reference standard values calculated from reference pulse sequences using the Nelder-Mead Simplex optimisation method. The proposed modules support current commonly available MRI pulse sequences and both 2- and 3-parameter curve fitting. Images acquired in patients using three major vendors showed vendor-independence. Bias and variability showed high agreement with T1 and T2 reference standards for T1 (range 214-1752ms) and T2 (range 45-338ms), respectively. Conclusions: The developed and validated T1 and T2 mapping and quantification modules generated relaxation maps from current commonly used MRI sequences and multiple signal models. Patient applications showed usability for three major vendors.
  •  
8.
  • Cheimariotis, Grigorios Aris, et al. (författare)
  • Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT
  • 2018
  • Ingår i: Annals of Nuclear Medicine. - : Springer Science and Business Media LLC. - 0914-7187 .- 1864-6433. ; 32:2, s. 94-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. Methods: A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. Results: The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p < 0.001) in SPECT. There were similar observations when comparing reference volumes from CT and manual delineations in SPECT images, left lung (bias was − 10 ± 491, R = 0.60, p = 0.005) right lung (bias 36 ± 524 ml, R = 0.62, p = 0.004). Conclusion: Automated segmentation on SPECT images are on par with manual segmentation on SPECT images. Relative large volumetric differences between manual delineations of functional SPECT images and anatomical CT images confirms that lung segmentation of functional SPECT images is a challenging task. The current algorithm is a first step towards automatic quantification of wide range of measurements.
  •  
9.
  • Edlund, Jonathan, et al. (författare)
  • Validation and quantification of left ventricular function during exercise and free breathing from real-time cardiac magnetic resonance images
  • 2022
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Exercise cardiovascular magnetic resonance (CMR) can unmask cardiac pathology not evident at rest. Real-time CMR in free breathing can be used, but respiratory motion may compromise quantification of left ventricular (LV) function. We aimed to develop and validate a post-processing algorithm that semi-automatically sorts real-time CMR images according to breathing to facilitate quantification of LV function in free breathing exercise. A semi-automatic algorithm utilizing manifold learning (Laplacian Eigenmaps) was developed for respiratory sorting. Feasibility was tested in eight healthy volunteers and eight patients who underwent ECG-gated and real-time CMR at rest. Additionally, volunteers performed exercise CMR at 60% of maximum heart rate. The algorithm was validated for exercise by comparing LV mass during exercise to rest. Respiratory sorting to end expiration and end inspiration (processing time 20 to 40 min) succeeded in all research participants. Bias ± SD for LV mass was 0 ± 5 g when comparing real-time CMR at rest, and 0 ± 7 g when comparing real-time CMR during exercise to ECG-gated at rest. This study presents a semi-automatic algorithm to retrospectively perform respiratory sorting in free breathing real-time CMR. This can facilitate implementation of exercise CMR with non-ECG-gated free breathing real-time imaging, without any additional physiological input.
  •  
10.
  • Engblom, Henrik, et al. (författare)
  • A new automatic algorithm for quantification of myocardial infarction imaged by late gadolinium enhancement cardiovascular magnetic resonance : Experimental validation and comparison to expert delineations in multi-center, multi-vendor patient data
  • 2016
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 18:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) using magnitude inversion recovery (IR) or phase sensitive inversion recovery (PSIR) has become clinical standard for assessment of myocardial infarction (MI). However, there is no clinical standard for quantification of MI even though multiple methods have been proposed. Simple thresholds have yielded varying results and advanced algorithms have only been validated in single center studies. Therefore, the aim of this study was to develop an automatic algorithm for MI quantification in IR and PSIR LGE images and to validate the new algorithm experimentally and compare it to expert delineations in multi-center, multi-vendor patient data. Methods: The new automatic algorithm, EWA (Expectation Maximization, weighted intensity, a priori information), was implemented using an intensity threshold by Expectation Maximization (EM) and a weighted summation to account for partial volume effects. The EWA algorithm was validated in-vivo against triphenyltetrazolium-chloride (TTC) staining (n = 7 pigs with paired IR and PSIR images) and against ex-vivo high resolution T1-weighted images (n = 23 IR and n = 13 PSIR images). The EWA algorithm was also compared to expert delineation in 124 patients from multi-center, multi-vendor clinical trials 2-6 days following first time ST-elevation myocardial infarction (STEMI) treated with percutaneous coronary intervention (PCI) (n = 124 IR and n = 49 PSIR images). Results: Infarct size by the EWA algorithm in vivo in pigs showed a bias to ex-vivo TTC of -1 ± 4%LVM (R = 0.84) in IR and -2 ± 3%LVM (R = 0.92) in PSIR images and a bias to ex-vivo T1-weighted images of 0 ± 4%LVM (R = 0.94) in IR and 0 ± 5%LVM (R = 0.79) in PSIR images. In multi-center patient studies, infarct size by the EWA algorithm showed a bias to expert delineation of -2 ± 6 %LVM (R = 0.81) in IR images (n = 124) and 0 ± 5%LVM (R = 0.89) in PSIR images (n = 49). Conclusions: The EWA algorithm was validated experimentally and in patient data with a low bias in both IR and PSIR LGE images. Thus, the use of EM and a weighted intensity as in the EWA algorithm, may serve as a clinical standard for the quantification of myocardial infarction in LGE CMR images. Clinical trial registration: CHILL-MI: NCT01379261. MITOCARE: NCT01374321.
  •  
11.
  • Engblom, Henrik, et al. (författare)
  • Diagnostic confidence with quantitative cardiovascular magnetic resonance perfusion mapping increases with increased coverage of the left ventricle
  • 2024
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - 1097-6647. ; 26:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Quantitative cardiovascular magnetic resonance (CMR) first pass perfusion maps are conventionally acquired with 3 short-axis (SAX) views (basal, mid, and apical) in every heartbeat (3SAX/1RR). Thus, a significant part of the left ventricle (LV) myocardium, including the apex, is not covered. The aims of this study were 1) to investigate if perfusion maps acquired with 3 short-axis views sampled every other RR-interval (2RR) yield comparable quantitative measures of myocardial perfusion (MP) as 1RR and 2) to assess if acquiring 3 additional perfusion views (i.e., total of 6) every other RR-interval (2RR) increases diagnostic confidence. Methods: In 287 patients with suspected ischemic heart disease stress and rest MP were performed on clinical indication on a 1.5T MR scanner. Eighty-three patients were examined by acquiring 3 short-axis perfusion maps with 1RR sampling (3SAX/1RR); for which also 2RR maps were reconstructed. Additionally, in 103 patients 3 short-axis and 3 long-axis (LAX; 2-, 3, and 4-chamber view) perfusion maps were acquired using 2RR sampling (3SAX + 3LAX/2RR) and in 101 patients 6 short-axis perfusion maps using 2RR sampling (6SAX/2RR) were acquired. The diagnostic confidence for ruling in or out stress-induced ischemia was scored according to a Likert scale (certain ischemia [2 points], probably ischemia [1 point], uncertain [0 points], probably no ischemia [1 point], certain no ischemia [2 points]). Results: There was a strong correlation (R = 0.99) between 3SAX/1RR and 3SAX/2RR for global MP (mL/min/g). The diagnostic confidence score increased significantly when the number of perfusion views was increased from 3 to 6 (1.24 ± 0.68 vs 1.54 ± 0.64, p < 0.001 with similar increase for 3SAX+3LAX/2RR (1.29 ± 0.68 vs 1.55 ± 0.65, p < 0.001) and for 6SAX/2RR (1.19 ± 0.69 vs 1.53 ± 0.63, p < 0.001). Conclusion: Quantitative perfusion mapping with 2RR sampling of data yields comparable perfusion values as 1RR sampling, allowing for the acquisition of additional views within the same perfusion scan. The diagnostic confidence for stress-induced ischemia increases when adding 3 additional views, short- or long axes, to the conventional 3 short-axis views. Thus, future development and clinical implementation of quantitative CMR perfusion should aim at increasing the LV coverage from the current standard using 3 short-axis views.
  •  
12.
  • Engblom, Henrik, et al. (författare)
  • Fully quantitative cardiovascular magnetic resonance myocardial perfusion ready for clinical use : A comparison between cardiovascular magnetic resonance imaging and positron emission tomography
  • 2017
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 19:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Recent studies have shown that quantification of myocardial perfusion (MP) at stress and myocardial perfusion reserve (MPR) offer additional diagnostic and prognostic information compared to qualitative and semi-quantitative assessment of myocardial perfusion distribution in patients with coronary artery disease (CAD). Technical advancements have enabled fully automatic quantification of MP using cardiovascular magnetic resonance (CMR) to be performed in-line in a clinical workflow. The aim of this study was to validate the use of the automated CMR perfusion mapping technique for quantification of MP using 13N-NH3 cardiac positron emission tomography (PET) as the reference method. Methods: Twenty-one patients with stable CAD were included in the study. All patients underwent adenosine stress and rest perfusion imaging with 13N-NH3 PET and a dual sequence, single contrast bolus CMR on the same day. Global and regional MP were quantified both at stress and rest using PET and CMR. Results: There was good agreement between global MP quantified by PET and CMR both at stress (-0.1 ± 0.5 ml/min/g) and at rest (0 ± 0.2 ml/min/g) with a strong correlation (r = 0.92, p < 0.001; y = 0.94× + 0.14). Furthermore, there was strong correlation between CMR and PET with regards to regional MP (r = 0.83, p < 0.001; y = 0.87× + 0.26) with a good agreement (-0.1 ± 0.6 ml/min/g). There was also a significant correlation between CMR and PET with regard to global and regional MPR (r = 0.69, p = 0.001 and r = 0.57, p < 0.001, respectively). Conclusions: There is good agreement between MP quantified by 13N-NH3 PET and dual sequence, single contrast bolus CMR in patients with stable CAD. Thus, CMR is viable in clinical practice for quantification of MP.
  •  
13.
  • Engblom, Henrik, et al. (författare)
  • Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
  • 2018
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Cardiovascular magnetic resonance (CMR) can be used to calculate myocardial extracellular volume fraction (ECV) by relating the longitudinal relaxation rate in blood and myocardium before and after contrast-injection to hematocrit (Hct) in blood. Hematocrit is known to vary with body posture, which could affect the calculations of ECV. The aim of this study was to test the hypothesis that there is a significant increase in calculated ECV values if the Hct is sampled after the CMR examination in supine position compared to when the patient arrives at the MR department. Methods: Forty-three consecutive patients including various pathologies as well as normal findings were included in the study. Venous blood samples were drawn upon arrival to the MR department and directly after the examination with the patient remaining in supine position. A Modified Look-Locker Inversion recovery (MOLLI) protocol was used to acquire mid-ventricular short-axis images before and after contrast injection from which motion-corrected T1 maps were derived and ECV was calculated. Results: Hematocrit decreased from 44.0 ± 3.7% before to 40.6 ± 4.0% after the CMR examination (p < 0.001). This resulted in a change in calculated ECV from 24.7 ± 3.8% before to 26.2 ± 4.2% after the CMR examination (p < 0.001). All patients decreased in Hct after the CMR examination compared to before except for two patients whose Hct remained the same. Conclusion: Variability in CMR-derived myocardial ECV can be reduced by standardizing the timing of Hct measurement relative to the CMR examination. Thus, a standardized acquisition of blood sample for Hct after the CMR examination, when the patient is still in supine position, would increase the precision of ECV measurements.
  •  
14.
  • Grigorios-Aris, Cheimariotis, et al. (författare)
  • Automatic segmentation of lungs in SPECT images using active shape model trained by meshes delineated in CT images
  • 2016
  • Ingår i: 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016. - 9781457702204 ; 2016-October, s. 1280-1283
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a fully automated method for segmentation of 3D SPECT ventilation and perfusion images. It relies on statistical information on lung shape derived by CT manual segmentation and its main processing steps are: shape model extraction, binary segmentation, positioning of mean shape in SPECT images and iterative shape adaptation based on intensity profiles and on what is considered 'plausible' lung shape. The Active Shape Model is used to generate accurate anatomic results in SPECT images with functional information and thus unclear borders, especially in the case of pathologies. The method was compared against ground truth manual segmentation on CT images, using volumetric, difference dice coefficient, sensitivity and precision.
  •  
15.
  •  
16.
  • Haris, Kostas, et al. (författare)
  • Free-breathing fetal cardiac MRI with doppler ultrasound gating, compressed sensing, and motion compensation
  • 2020
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 51:1, s. 260-272
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Fetal cardiovascular MRI complements ultrasound to assess fetal cardiovascular pathophysiology.PURPOSE: To develop a free-breathing method for retrospective fetal cine MRI using Doppler ultrasound (DUS) cardiac gating and tiny golden angle radial sampling (tyGRASP) for accelerated acquisition capable of detecting fetal movements for motion compensation.STUDY TYPE: Feasibility study.SUBJECTS: Nine volunteers (gestational week 34-40). Short-axis and four-chamber views were acquired during maternal free-breathing and breath-hold.FIELD STRENGTH/SEQUENCE: 1.5T cine balanced steady-state free precession.ASSESSMENT: A self-gated reconstruction method was improved for clinical application by using 1) retrospective DUS gating, and 2) motion detection and rejection/correction algorithms for compensating for fetal motion. The free-breathing reconstructions were qualitatively and quantitatively assessed, and DUS-gating was compared with self-gating in breath-hold reconstructions. A scoring of 1-4 for overall image quality, cardiac, and extracardiac diagnostic quality was used.STATISTICAL TESTS: Friedman's test was used to assess differences in qualitative scoring between observers. A Wilcoxon matched-pairs signed rank test was used to assess differences between breath-hold and free-breathing acquisitions and between observers' quantitative measurements.RESULTS: In all cases, 111 free-breathing and 145 breath-hold acquisitions, the automatically calculated DUS-based cardiac gating signal provided reconstructions of diagnostic quality (median score 4, range 1-4). Free-breathing did not affect the DUS-based cardiac gated retrospective radial reconstruction with respect to image or diagnostic quality (all P > 0.06). Motion detection with rejection/correction in k-space produced high-quality free-breathing DUS-based reconstructions [median 3, range (2-4)], whereas free-breathing self-gated methods failed in 80 out of 88 cases to produce a stable gating signal.DATA CONCLUSION: Free-breathing fetal cine cardiac MRI based on DUS gating and tyGRASP with motion compensation yields diagnostic images. This simplifies acquisition for the pregnant woman and thus could help increase fetal cardiac MRI acceptance in the clinic.LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019.
  •  
17.
  • Haris, Kostas, et al. (författare)
  • Self-gated fetal cardiac MRI with tiny golden angle iGRASP : A feasibility study
  • 2017
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 46:1, s. 207-217
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To develop and assess a technique for self-gated fetal cardiac cine magnetic resonance imaging (MRI) using tiny golden angle radial sampling combined with iGRASP (iterative Golden-angle RAdial Sparse Parallel) for accelerated acquisition based on parallel imaging and compressed sensing.MATERIALS AND METHODS: Fetal cardiac data were acquired from five volunteers in gestational week 29-37 at 1.5T using tiny golden angles for eddy currents reduction. The acquired multicoil radial projections were input to a principal component analysis-based compression stage. The cardiac self-gating (CSG) signal for cardiac gating was extracted from the acquired radial projections and the iGRASP reconstruction procedure was applied. In all acquisitions, a total of 4000 radial spokes were acquired within a breath-hold of less than 15 seconds using a balanced steady-state free precession pulse sequence. The images were qualitatively compared by two independent observers (on a scale of 1-4) to a single midventricular cine image from metric optimized gating (MOG) and real-time acquisitions.RESULTS: For iGRASP and MOG images, good overall image quality (2.8 ± 0.4 and 2.6 ± 1.3, respectively, for observer 1; 3.6 ± 0.5 and 3.4 ± 0.9, respectively, for observer 2) and cardiac diagnostic quality (3.8 ± 0.4 and 3.4 ± 0.9, respectively, for observer 1; 3.6 ± 0.5 and 3.6 ± 0.9, respectively, for observer 2) were obtained, with visualized myocardial thickening over the cardiac cycle and well-defined myocardial borders to ventricular lumen and liver/lung tissue. For iGRASP, MOG, and real time, left ventricular lumen diameter (14.1 ± 2.2 mm, 14.2 ± 1.9 mm, 14.7 ± 1.1 mm, respectively) and wall thickness (2.7 ± 0.3 mm, 2.6 ± 0.3 mm, 3.0 ± 0.4, respectively) showed agreement and no statistically significant difference was found (all P > 0.05). Images with iGRASP tended to have higher overall image quality scores compared with MOG and particularly real-time images, albeit not statistically significant in this feasibility study (P > 0.99 and P = 0.12, respectively).CONCLUSION: Fetal cardiac cine MRI can be performed with iGRASP using tiny golden angles and CSG. Comparison with other fetal cardiac cine MRI methods showed that the proposed method produces high-quality fetal cardiac reconstructions.LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017.
  •  
18.
  • Heiberg, Einar, et al. (författare)
  • Infarct quantification with cardiovascular magnetic resonance using "standard deviation from remote" is unreliable : validation in multi-centre multi-vendor data
  • 2022
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 24:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The objective of the study was to investigate variability and agreement of the commonly used image processing method “n-SD from remote” and in particular for quantifying myocardial infarction by late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR). LGE-CMR in tandem with the analysis method “n-SD from remote” represents the current reference standard for infarct quantification. This analytic method utilizes regions of interest (ROIs) and defines infarct as the tissue with a set number of standard deviations (SD) above the signal intensity of remote nulled myocardium. There is no consensus on what the set number of SD is supposed to be. Little is known about how size and location of ROIs and underlying signal properties in the LGE images affect results. Furthermore, the method is frequently used elsewhere in medical imaging often without careful validation. Therefore, the usage of the “n-SD” method warrants a thorough validation. Methods: Data from 214 patients from two multi-center cardioprotection trials were included. Infarct size from different remote ROI positions, ROI size, and number of standard deviations (“n-SD”) were compared with reference core lab delineations. Results: Variability in infarct size caused by varying ROI position, ROI size, and “n-SD” was 47%, 48%, and 40%, respectively. The agreement between the “n-SD from remote” method and the reference infarct size by core lab delineations was low. Optimal “n-SD” threshold computed on a slice-by-slice basis showed high variability, n = 5.3 ± 2.2. Conclusion: The “n-SD from remote” method is unreliable for infarct quantification due to high variability which depends on different placement and size of remote ROI, number “n-SD”, and image signal properties related to the CMR-scanner and sequence used. Therefore, the “n-SD from remote” method should not be used, instead methods validated against an independent standard are recommended.
  •  
19.
  • Iakovidis, Dimitris K., et al. (författare)
  • Roadmap on signal processing for next generation measurement systems
  • 2022
  • Ingår i: Measurement Science and Technology. - : IOP Publishing. - 0957-0233 .- 1361-6501. ; 33:1
  • Forskningsöversikt (refereegranskat)abstract
    • Signal processing is a fundamental component of almost any sensor-enabled system, with a wide range of applications across different scientific disciplines. Time series data, images, and video sequences comprise representative forms of signals that can be enhanced and analysed for information extraction and quantification. The recent advances in artificial intelligence and machine learning are shifting the research attention towards intelligent, data-driven, signal processing. This roadmap presents a critical overview of the state-of-the-art methods and applications aiming to highlight future challenges and research opportunities towards next generation measurement systems. It covers a broad spectrum of topics ranging from basic to industrial research, organized in concise thematic sections that reflect the trends and the impacts of current and future developments per research field. Furthermore, it offers guidance to researchers and funding agencies in identifying new prospects.
  •  
20.
  • Ibanez, Borja, et al. (författare)
  • Cardiac MRI Endpoints in Myocardial Infarction Experimental and Clinical Trials : JACC Scientific Expert Panel
  • 2019
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097. ; 74:2, s. 238-256
  • Forskningsöversikt (refereegranskat)abstract
    • After a reperfused myocardial infarction (MI), dynamic tissue changes occur (edema, inflammation, microvascular obstruction, hemorrhage, cardiomyocyte necrosis, and ultimately replacement by fibrosis). The extension and magnitude of these changes contribute to long-term prognosis after MI. Cardiac magnetic resonance (CMR) is the gold-standard technique for noninvasive myocardial tissue characterization. CMR is also the preferred methodology for the identification of potential benefits associated with new cardioprotective strategies both in experimental and clinical trials. However, there is a wide heterogeneity in CMR methodologies used in experimental and clinical trials, including time of post-MI scan, acquisition protocols, and, more importantly, selection of endpoints. There is a need for standardization of these methodologies to improve the translation into a real clinical benefit. The main objective of this scientific expert panel consensus document is to provide recommendations for CMR endpoint selection in experimental and clinical trials based on pathophysiology and its association with hard outcomes.
  •  
21.
  • Jablonowski, Robert, et al. (författare)
  • Quantitative myocardial perfusion during stress using CMR is impaired in healthy Middle Eastern immigrants without CV risk factors
  • 2022
  • Ingår i: Scientific Reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Middle Eastern immigrants constitute a growing proportion of the European population and compared to native Swedes are more insulin resistant, which can contribute to atherosclerosis. Quantitative first pass perfusion (qFPP) using cardiovascular magnetic resonance (CMR) can detect early signs of cardiovascular disease (CVD). The aim was to study if myocardial perfusion differs between healthy male Middle Eastern immigrants and native male Swedes. Eighteen Iraqi- and twelve Swedish born controls, all males, never smokers with no CVD risk factors were included. Global myocardial perfusion at rest and stress was assessed using qFPP and by phase-contrast CMR imaging of coronary sinus flow. Quantitative first pass perfusion analysis (mean ± SD) demonstrated no difference at rest between Iraqi and Swedish males (0.8 ± 0.2 vs 1.0 ± 0.4 ml/min/g, P = 0.38) but lower perfusion during adenosine in Iraqi males (2.9 ± 0.7 vs 3.5 ± 0.7 ml/min/g, P = 0.02). Myocardial perfusion assessed by coronary sinus flow demonstrated similar results with no difference in resting perfusion between groups (0.7 ± 0.2 vs 0.8 ± 0.2 ml/min/g, P = 0.21) but a lower perfusion during adenosine in the Iraqi group (3.0 ± 0.2 vs 3.7 ± 0.6 ml/min/g, P = 0.01. Myocardial perfusion during adenosine stress was lower in healthy Iraqi immigrants compared to Swedish controls suggesting impaired microvascular function and risk of underestimating CVD risk in healthy individuals of Middle Eastern origin.
  •  
22.
  •  
23.
  • Kantasis, George, et al. (författare)
  • Cloud GPU-based simulations for SQUAREMR
  • 2017
  • Ingår i: Journal of Magnetic Resonance. - : Elsevier BV. - 1090-7807. ; 274, s. 80-88
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantitative Magnetic Resonance Imaging (MRI) is a research tool, used more and more in clinical practice, as it provides objective information with respect to the tissues being imaged. Pixel-wise T1 quantification (T1 mapping) of the myocardium is one such application with diagnostic significance. A number of mapping sequences have been developed for myocardial T1 mapping with a wide range in terms of measurement accuracy and precision. Furthermore, measurement results obtained with these pulse sequences are affected by errors introduced by the particular acquisition parameters used. SQUAREMR is a new method which has the potential of improving the accuracy of these mapping sequences through the use of massively parallel simulations on Graphical Processing Units (GPUs) by taking into account different acquisition parameter sets. This method has been shown to be effective in myocardial T1 mapping; however, execution times may exceed 30 min which is prohibitively long for clinical applications. The purpose of this study was to accelerate the construction of SQUAREMR's multi-parametric database to more clinically acceptable levels. The aim of this study was to develop a cloud-based cluster in order to distribute the computational load to several GPU-enabled nodes and accelerate SQUAREMR. This would accommodate high demands for computational resources without the need for major upfront equipment investment. Moreover, the parameter space explored by the simulations was optimized in order to reduce the computational load without compromising the T1 estimates compared to a non-optimized parameter space approach. A cloud-based cluster with 16 nodes resulted in a speedup of up to 13.5 times compared to a single-node execution. Finally, the optimized parameter set approach allowed for an execution time of 28 s using the 16-node cluster, without compromising the T1 estimates by more than 10 ms. The developed cloud-based cluster and optimization of the parameter set reduced the execution time of the simulations involved in constructing the SQUAREMR multi-parametric database thus bringing SQUAREMR's applicability within time frames that would be likely acceptable in the clinic.
  •  
24.
  • Kording, Fabian, et al. (författare)
  • Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating
  • 2018
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies. However, dynamic fetal CMR is difficult due to the lack of direct in-utero cardiac gating. The aim of this study was to investigate the effectiveness of a newly developed Doppler ultrasound (DUS) device in humans for fetal CMR gating. Methods: Fifteen fetuses (gestational age 30-39 weeks) were examined using 1.5 T CMR scanners at three different imaging sites. A newly developed CMR-compatible DUS device was used to generate gating signals from fetal cardiac motion. Gated dynamic balanced steady-state free precession images were acquired in 4-chamber and short-axis cardiac views. Gating signals during data acquisition were analyzed with respect to trigger variability and sensitivity. Image quality was assessed by measuring endocardial blurring (EB) and by image evaluation using a 4-point scale. Left ventricular (LV) volumetry was performed using the single-plane ellipsoid model. Results: Gating signals from the fetal heart were detected with a variability of 26 ± 22 ms and a sensitivity of trigger detection of 96 ± 4%. EB was 2.9 ± 0.6 pixels (4-chamber) and 2.5 ± 0.1 pixels (short axis). Image quality scores were 3.6 ± 0.6 (overall), 3.4 ± 0.7 (mitral valve), 3.4 ± 0.7 (foramen ovale), 3.6 ± 0.7 (atrial septum), 3.7 ± 0.5 (papillary muscles), 3.8 ± 0.4 (differentiation myocardium/lumen), 3.7 ± 0.5 (differentiation myocardium/lung), and 3.9 ± 0.4 (systolic myocardial thickening). Inter-observer agreement for the scores was moderate to very good (kappa 0.57-0.84) for all structures. LV volumetry revealed mean values of 2.8 ± 1.2 ml (end-diastolic volume), 0.9 ± 0.4 ml (end systolic volume), 1.9 ± 0.8 ml (stroke volume), and 69.1 ± 8.4% (ejection fraction). Conclusion: High-quality dynamic fetal CMR was successfully performed using a newly developed DUS device for direct fetal cardiac gating. This technique has the potential to improve the utility of fetal CMR in the evaluation of congenital pathologies.
  •  
25.
  • Nordlund, David, et al. (författare)
  • Experimental validation of contrast-enhanced SSFP cine CMR for quantification of myocardium at risk in acute myocardial infarction
  • 2017
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 19:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Accurate assessment of myocardium at risk (MaR) after acute myocardial infarction (AMI) is necessary when assessing myocardial salvage. Contrast-enhanced steady-state free precession (CE-SSFP) is a recently developed cardiovascular magnetic resonance (CMR) method for assessment of MaR up to 1 week after AMI. Our aim was to validate CE-SSFP for determination of MaR in an experimental porcine model using myocardial perfusion single-photon emission computed tomography (MPS) as a reference standard and to test the stability of MaR-quantification over time after injecting gadolinium-based contrast. Methods: Eleven pigs were subjected to either 35 or 40 min occlusion of the left anterior descending artery followed by six hours of reperfusion. A technetium-based perfusion tracer was administered intravenously ten minutes before reperfusion. In-vivo and ex-vivo CE-SSFP CMR was performed followed by ex-vivo MPS imaging. MaR was expressed as % of left ventricular mass (LVM). Results: There was good agreement between MaR by ex-vivo CMR and MaR by MPS (bias: 1 ± 3% LVM, r 2 = 0.92, p < 0.001), between ex-vivo and in-vivo CMR (bias 0 ± 2% LVM, r 2 = 0.94, p < 0.001) and between in-vivo CMR and MPS (bias -2 ± 3% LVM, r 2 = 0.87, p < 0.001. No change in MaR was seen over the first 30 min after contrast injection (p = 0.95). Conclusions: Contrast-enhanced SSFP cine CMR can be used to measure MaR, both in vivo and ex vivo, in a porcine model with good accuracy and precision over the first 30 min after contrast injection. This offers the option to use the less complex ex-vivo imaging when determining myocardial salvage in experimental studies.
  •  
26.
  • Nordlund, David, et al. (författare)
  • Extent of myocardium at risk for left anterior descending artery, right coronary artery, and left circumflex artery occlusion depicted by contrast-enhanced steady state free precession and T2-weighted short tau inversion recovery magnetic resonance imaging
  • 2016
  • Ingår i: Circulation Cardiovascular Imaging. - 1941-9651. ; 9:7
  • Tidskriftsartikel (refereegranskat)abstract
    • Background - Contrast-enhanced steady state free precession (CE-SSFP) and T2-weighted short tau inversion recovery (T2-STIR) have been clinically validated to estimate myocardium at risk (MaR) by cardiovascular magnetic resonance while using myocardial perfusion single-photon emission computed tomography as reference standard. Myocardial perfusion single-photon emission computed tomography has been used to describe the coronary perfusion territories during myocardial ischemia. Compared with myocardial perfusion single-photon emission computed tomography, cardiovascular magnetic resonance offers superior image quality and practical advantages. Therefore, the aim was to describe the main coronary perfusion territories using CE-SSFP and T2-STIR cardiovascular magnetic resonance data in patients after acute ST-segment-elevation myocardial infarction. Methods and Results - CE-SSFP and T2-STIR data from 2 recent multicenter trials, CHILL-MI and MITOCARE (n=215), were used to assess MaR. Angiography was used to determine culprit vessel. Of 215 patients, 39% had left anterior descending artery occlusion, 49% had right coronary artery occlusion, and 12% had left circumflex artery occlusion. Mean extent of MaR using CE-SSFP was 44±10% for left anterior descending artery, 31±7% for right coronary artery, and 30±9% for left circumflex artery. Using T2-STIR, MaR was 44±9% for left anterior descending artery, 30±8% for right coronary artery, and 30±12% for left circumflex artery. MaR was visualized in polar plots, and expected overlap was found between right coronary artery and left circumflex artery. Detailed regional data are presented for use in software algorithms as a priori information on the extent of MaR. Conclusions - For the first time, cardiovascular magnetic resonance has been used to show the main coronary perfusion territories using CE-SSFP and T2-STIR. The good agreement between CE-SSFP and T2-STIR from this study and myocardial perfusion single-photon emission computed tomography from previous studies indicates that these 3 methods depict MaR accurately in individual patients and at a group level. Clinical Trial Registration - URL: http://www.clinicaltrials.gov. Unique identifiers: NCT01379261 and NCT01374321.
  •  
27.
  • Nordlund, David, et al. (författare)
  • Measuring extracellular volume fraction by MRI : First verification of values given by clinical sequences
  • 2020
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 83:2, s. 662-672
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To verify MR measurements of myocardial extracellular volume fraction (ECV) based on clinically applicable T1-mapping sequences against ECV measurements by radioisotope tracer in pigs and to relate the results to those obtained in volunteers.METHODS: Between May 2016 and March 2017, 8 volunteers (25 ± 4 years, 3 female) and 8 pigs (4 female) underwent ECV assessment with SASHA, MOLLI5(3b)3, MOLLI5(3s)3, and MOLLI5s(3s)3s. Myocardial ECV was measured independently in pigs using a radioisotope tracer method.RESULTS: In pigs, ECV in normal myocardium was not different between radioisotope (average ± standard deviation; 19 ± 2%) and SASHA (21 ± 2%; P = 0.086). ECV was higher by MOLLI5(3b)3 (26 ± 2%), MOLLI5(3s)3 (25 ± 2%), and MOLLI5s(3s)3s (25 ± 2%) compared with SASHA or radioisotope (P ≤ 0.001 for all). ECV in volunteers was higher by MOLLI5(3b)3 (26 ± 3%) and MOLLI5(3s)3 (26 ± 3%) than by SASHA (22 ± 3%; P = 0.022 and P = 0.033). No difference was found between MOLLI5s(3s)3s (25 ± 3%) and SASHA (P = 0.225). Native T1 of blood and myocardium as well as postcontrast T1 of myocardium was consistently lower using MOLLI compared with SASHA. ECV increased over time as measured by MOLLI5(3b)3 and MOLLI5(3s)3 for pigs (0.08% and 0.07%/min; P = 0.004 and P = 0.013) and by MOLLI5s(3s)3s for volunteers (0.07%/min; P = 0.032) but did not increase as measured by SASHA.CONCLUSION: Clinically available MOLLI and SASHA techniques can be used to accurately estimate ECV in normal myocardium where MOLLI-sequences show minor overestimation driven by underestimation of postcontrast T1 when compared with SASHA. The timing of imaging after contrast administration affected the measurement of ECV using some variants of the MOLLI sequence.
  •  
28.
  • Piek, Marjolein, et al. (författare)
  • Fetal 3D cardiovascular cine image acquisition using radial sampling and compressed sensing
  • 2023
  • Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 89:2, s. 594-604
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To explore a fetal 3D cardiovascular cine acquisition using a radial image acquisition and compressed-sensing reconstruction and compare image quality and scan time with conventional multislice 2D imaging.METHODS: Volumetric fetal cardiac data were acquired in 26 volunteers using a radial 3D balanced SSFP pulse sequence. Cardiac gating was performed using a Doppler ultrasound device. Images were reconstructed using a parallel-imaging and compressed-sensing algorithm. Multiplanar reformatting to standard cardiac views was performed before image analysis. Clinical 2D images were used for comparison. Qualitative and quantitative image evaluation were performed by two experienced observers (scale: 1-4). Volumes, mass, and function were assessed.RESULTS: Average scan time for the 3D imaging was 6 min, including one localizer. A 2D imaging stack covering the entire heart including localizer sequences took at least 6.5 min, depending on planning complexity. The 3D acquisition was successful in 7 of 26 subjects (27%). Overall image contrast and perceived resolution were lower in the 3D images. Nonetheless, the 3D images had, on average, a moderate cardiac diagnostic quality (median [range]: 3 [1-4]). Standard clinical 2D acquisitions had a high cardiac diagnostic quality (median [range]: 4 [3, 4]). Cardiac measurements were not different between 2D and 3D images (all p > 0.16).CONCLUSION: The presented free-breathing whole-heart fetal 3D radial cine MRI acquisition and reconstruction method enables retrospective visualization of all cardiac views while keeping examination times short. This proof-of-concept work produced images with diagnostic quality, while at the same time reducing the planning complexity to a single localizer.
  •  
29.
  • Ryd, Daniel, et al. (författare)
  • Quantification of blood flow in the fetus with cardiovascular magnetic resonance imaging using Doppler ultrasound gating : validation against metric optimized gating
  • 2019
  • Ingår i: Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647. ; 21
  • Tidskriftsartikel (refereegranskat)abstract
    • INTRODUCTION: Fetal cardiovascular magnetic resonance (CMR) imaging is used clinically and for research, but has been previously limited due to lack of direct gating methods. A CMR-compatible Doppler ultrasound (DUS) gating device has resolved this. However, the DUS-gating method is not validated against the current reference method for fetal phase-contrast blood flow measurements, metric optimized gating (MOG). Further, we investigated how different methods for vessel delineation affect flow volumes and observer variability in fetal flow acquisitions.AIMS: To 1) validate DUS gating versus MOG for quantifying fetal blood flow; 2) assess repeatability of DUS gating; 3) assess impact of region of interest (ROI) size on flow volume; and 4) compare time-resolved and static delineations for flow volume and observer variability.METHODS: Phase-contrast CMR was acquired in the fetal descending aorta (DAo) and umbilical vein by DUS gating and MOG in 22 women with singleton pregnancy in gestational week 360 (265-400) with repeated scans in six fetuses. Impact of ROI size on measured flow was assessed for ROI:s 50-150% of the vessel diameter. Four observers from two centers provided time-resolved and static delineations. Bland-Altman analysis was used to determine agreement between both observers and methods.RESULTS: DAo flow was 726 (348-1130) ml/min and umbilical vein flow 366 (150-782) ml/min by DUS gating. Bias±SD for DUS-gating versus MOG were - 45 ± 122 ml/min (-6 ± 15%) for DAo and 19 ± 136 ml/min (2 ± 24%) for umbilical vein flow. Repeated flow measurements in the same fetus showed similar volumes (median CoV = 11% (DAo) and 23% (umbilical vein)). Region of interest 50-150% of vessel diameter yielded flow 35-120%. Bias±SD for time-resolved versus static DUS-gated flow was 33 ± 39 ml/min (4 ± 6%) for DAo and 11 ± 84 ml/min (2 ± 15%) for umbilical vein flow.CONCLUSIONS: Quantification of blood flow in the fetal DAo and umbilical vein using DUS-gated phase-contrast CMR is feasible and agrees with the current reference method. Repeatability was generally high for CMR fetal blood flow assessment. An ROI similar to the vessel area or slightly larger is recommended. A static ROI is sufficient for fetal flow quantification using currently available CMR sequences.
  •  
30.
  • Vavoulas, Alexander, et al. (författare)
  • Using a modified 3D-printer for mapping the magnetic field of RF coils designed for fetal and neonatal imaging
  • 2016
  • Ingår i: Journal of Magnetic Resonance. - : Elsevier BV. - 1090-7807. ; 269, s. 146-151
  • Tidskriftsartikel (refereegranskat)abstract
    • An experimental setup for characterizing the magnetic field of MRI RF coils was proposed and tested. The setup consisted of a specially configured 3D-printer, a network analyzer and a mid-performance desktop PC. The setup was tested on a single loop RF coil, part of a phased array for fetal imaging. Then, the setup was used for determining the magnetic field characteristics of a high-pass birdcage coil used for neonatal MR imaging with a vertical static field. The scattering parameter S21, converted into power ratio, was used for mapping the B1 magnetic field. The experimental measurements from the loop coil were close to the theoretical results (R = 0.924). A high degree of homogeneity was measured for the neonatal birdcage RF coil. The development of MR RF coils is time consuming and resource intensive. The proposed experimental setup provides an alternative method for magnetic field characterization of RF coils used in MRI.
  •  
31.
  • Xanthis, Christos G., et al. (författare)
  • Simulation-based quantification of native T1 and T2 of the myocardium using a modified MOLLI scheme and the importance of Magnetization Transfer
  • 2018
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 0730-725X. ; 48, s. 96-106
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantitative cardiovascular Magnetic Resonance Imaging techniques are gaining wide acceptance within the MR community due to their potential to diagnose non-localized disease, guide therapy and improve patient outcome. During the last decade, there has been an increasing interest for developing new techniques that allow for simultaneous quantification of both T1 and T2 maps of myocardium. Newer studies demonstrated that the incorporation of MRI simulations could yield similar results to conventional mapping techniques in the myocardium. However, these simulation-based quantitative MR techniques usually compare the in-vivo T1 estimates against less accurate T1 techniques, whereas they present inconsistencies between simulation studies, phantom and in-vivo measurements. Moreover, these studies do not investigate the effect of Magnetization Transfer on the myocardial T1 and T2 estimates but are usually validated on phantoms where the MT effect is small. The main aim of this study was to perform simultaneous mapping of the native T1 and T2 of the myocardium through the utilization of a modified MOLLI pulse sequence and the incorporation of advanced MR simulations through the SQUAREMR framework. A second aim of this study was to investigate the effect of MT on simulation-based quantitative MR techniques. A conventional MOLLI pulse sequence was modified so as to present combined high T2 sensitivity and low MT effect. The new technique was applied in healthy volunteers and demonstrated an improved T1 accuracy compared to the conventional MOLLI and a T2 accuracy similar to the one provided by the T2prep-bSSFP method. The effect of MT on T1 and T2 estimates was also investigated in the current study. Phantoms with an increasing MT effect as well as phantoms without an MT effect were included in this work whereas several variants of the modified-MOLLI that introduce different amounts of T2 modulation on the MR signal and induce different MT effects were applied on the phantoms. The proposed simulation-based quantitative MR technique for simultaneous T1 and T2 mapping of the myocardium does not require the incorporation of a complicated custom designed pulse sequence and does not require a complicated reconstruction workflow. Moreover, the current study demonstrates for the first time that MT plays an important role in the simulation-based quantitative MR studies and points out the necessity of incorporating the study of MT in future techniques.
  •  
32.
  • Xanthis, Christos G., et al. (författare)
  • Unravelling the mechanisms of CE-SSFP in imaging myocardium at risk : The effect of relaxation times on myocardial contrast
  • 2024
  • Ingår i: Magnetic Resonance Imaging. - 0730-725X. ; 111, s. 90-102
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The aim of this study was to investigate the contrast mechanisms of Contrast-enhanced steady-state free-precession (CE-SSFP) through the utilization of Bloch simulations in an experimental porcine model and in patients with acute myocardial infarction. Methods: Six pigs and ten patients with myocardial infarction underwent CMR and tissue characterization at 1.5 T whereas a Bloch simulation framework was utilized to simulate the CE-SSFP signal formation and compare it against the actual CE-SSFP signal acquired from the experimental porcine model and the patient population. The relaxation times of remote, salvaged, and infarcted myocardium were calculated after the injection of gadolinium, at the time of CE-SSFP acquisition. Simulations were performed using the same CE-SSFP pulse sequence as used on the scanner on a set of spins with the calculated relaxation times from the CMR scans. Results: The normalized signal intensities of salvaged and infarcted myocardium obtained with simulations were lower than the corresponding normalized signal intensities obtained in vivo in pigs (p < 0.05, 134% vs 153%) and in patients (p < 0.05, 126% vs 145%). The results from simulations showed a linear relationship to the results obtained in the experimental porcine model (r2 = 0.61) and in patients (r2 = 0.69). Conclusion: The T1 and T2 values of remote, salvaged, and infarcted myocardium only partly explain the signal intensities in CE-SSFP images. Bloch simulations suggest that there may be more elements that contribute to the CE-SSFP contrast. Integration of other aspects of the MR experiment into the simulation model could further help to fully unravel the mechanisms of CE-SSFP.
  •  
Skapa referenser, mejla, bekava och länka