1. |
- Ahuja, Vasudha, et al.
(författare)
-
Accuracy of 1-Hour Plasma Glucose During the Oral Glucose Tolerance Test in Diagnosis of Type 2 Diabetes in Adults : A Meta-analysis
- 2021
-
Ingår i: Diabetes Care. - : American Diabetes Association. - 1935-5548 .- 0149-5992. ; 44:4, s. 1062-1069
-
Forskningsöversikt (refereegranskat)abstract
- OBJECTIVE: One-hour plasma glucose (1-h PG) during the oral glucose tolerance test (OGTT) is an accurate predictor of type 2 diabetes. We performed a meta-analysis to determine the optimum cutoff of 1-h PG for detection of type 2 diabetes using 2-h PG as the gold standard. RESEARCH DESIGN AND METHODS: We included 15 studies with 35,551 participants from multiple ethnic groups (53.8% Caucasian) and 2,705 newly detected cases of diabetes based on 2-h PG during OGTT. We excluded cases identified only by elevated fasting plasma glucose and/or HbA1c. We determined the optimal 1-h PG threshold and its accuracy at this cutoff for detection of diabetes (2-h PG ≥11.1 mmol/L) using a mixed linear effects regression model with different weights to sensitivity/specificity (2/3, 1/2, and 1/3). RESULTS: Three cutoffs of 1-h PG, at 10.6 mmol/L, 11.6 mmol/L, and 12.5 mmol/L, had sensitivities of 0.95, 0.92, and 0.87 and specificities of 0.86, 0.91, and 0.94 at weights 2/3, 1/2, and 1/3, respectively. The cutoff of 11.6 mmol/L (95% CI 10.6, 12.6) had a sensitivity of 0.92 (0.87, 0.95), specificity of 0.91 (0.88, 0.93), area under the curve 0.939 (95% confidence region for sensitivity at a given specificity: 0.904, 0.946), and a positive predictive value of 45%. CONCLUSIONS: The 1-h PG of ≥11.6 mmol/L during OGTT has a good sensitivity and specificity for detecting type 2 diabetes. Prescreening with a diabetes-specific risk calculator to identify high-risk individuals is suggested to decrease the proportion of false-positive cases. Studies including other ethnic groups and assessing complication risk are warranted.
|
|
2. |
|
|
3. |
|
|
4. |
|
|
5. |
- Tedeschi, Rosamaria, et al.
(författare)
-
Activation of maternal Epstein-Barr virus infection and risk of acute leukemia in the offspring
- 2007
-
Ingår i: American Journal of Epidemiology. - : Oxford University Press (OUP). - 0002-9262 .- 1476-6256. ; 165:2, s. 134-137
-
Tidskriftsartikel (refereegranskat)abstract
- After identifying an association between maternal Epstein-Barr virus (EBV) reactivation and acute lymphoblastic leukemia (ALL), the authors analyzed a nested case-control study within Finnish and Icelandic maternity cohorts with 7 million years of follow-up to confirm EBV's role in ALL. Offspring of 550,000 mothers were followed up to age 15 years during 1975-1997 by national cancer registries to identify leukemia cases. Mothers of cases and three quarters of matched mothers of controls were identified by national population registers. First-trimester sera from mothers of 304 ALL cases and 39 non-ALL cases and from 943 mothers of controls were analyzed for antibodies to viral capsid antigen, early antigen, and EBV transactivator protein ZEBRA. Relative risk, estimated as odds ratio (95% confidence interval), was adjusted for birth order and sibship size. Combining early antigen and/or ZEBRA immunoglobulin G antibodies with the presence of viral capsid antigen immunoglobulin M antibodies did not increase the estimate for ALL risk for viral capsid antigen immunoglobulin M alone (odds ratio = 1.9, 95% confidence interval: 1.2, 3.0). Both ZEBRA immunoglobulin G antibodies and viral capsid antigen immunoglobulin M antibodies were associated with an increased risk of non-ALL in the offspring (odds ratio = 4.5, 95% confidence interval: 1.3, 16; odds ratio = 5.6, 95% confidence interval: 1.1, 29, respectively), suggesting EBV reactivation in the mothers of non-ALL cases. EBV reactivation may be associated with a proportion of childhood leukemia.
|
|