1. |
|
|
2. |
|
|
3. |
|
|
4. |
|
|
5. |
- Wilkoff, B. L., et al.
(författare)
-
Impact of Cardiac Implantable Electronic Device Infection A Clinical and Economic Analysis of the WRAP-IT Trial
- 2020
-
Ingår i: Circulation-Arrhythmia and Electrophysiology. - : Ovid Technologies (Wolters Kluwer Health). - 1941-3149 .- 1941-3084. ; 13:5
-
Tidskriftsartikel (refereegranskat)abstract
- Background: Current understanding of the impact of cardiac implantable electronic device (CIED) infection is based on retrospective analyses from medical records or administrative claims data. The WRAP-IT (Worldwide Randomized Antibiotic Envelope Infection Prevention Trial) offers an opportunity to evaluate the clinical and economic impacts of CIED infection from the hospital, payer, and patient perspectives in the US healthcare system. Methods: This was a prespecified, as-treated analysis evaluating outcomes related to major CIED infections: mortality, quality of life, disruption of CIED therapy, healthcare utilization, and costs. Payer costs were assigned using medicare fee for service national payments, while medicare advantage, hospital, and patient costs were derived from similar hospital admissions in administrative datasets. Results: Major CIED infection was associated with increased all-cause mortality (12-month risk-adjusted hazard ratio, 3.41 [95% CI, 1.81-6.41]; P<0.001), an effect that sustained beyond 12 months (hazard ratio through all follow-up, 2.30 [95% CI, 1.29-4.07]; P=0.004). Quality of life was reduced (P=0.004) and did not normalize for 6 months. Disruptions in CIED therapy were experienced in 36% of infections for a median duration of 184 days. Mean costs were $55 547 +/-$45 802 for the hospital, $26 867 +/-$14 893, for medicare fee for service and $57 978 +/-$29 431 for Medicare Advantage (mean hospital margin of -$30 828 +/-$39 757 for medicare fee for service and -$6055 +/-$45 033 for medicare advantage). Mean out-of-pocket costs for patients were $2156 +/-$1999 for medicare fee for service, and $1658 +/-$1250 for medicare advantage. Conclusions: This large, prospective analysis corroborates and extends understanding of the impact of CIED infections as seen in real-world datasets. CIED infections severely impact mortality, quality of life, healthcare utilization, and cost in the US healthcare system.
|
|
6. |
- Blomstrom-Lundqvist, C., et al.
(författare)
-
European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID), and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)
- 2020
-
Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 41:21, s. 2012-2032
-
Tidskriftsartikel (refereegranskat)abstract
- Pacemakers, implantable cardiac defibrillators, and cardiac resynchronization therapy devices are potentially lifesaving treatments for a number of cardiac conditions but are not without risk. Most concerning is the risk of a cardiac implantable electronic device (CIED) infection, which is associated with significant morbidity, increased hospitalizations, reduced survival, and increased health care costs. Recommended preventive strategies such as administration of intravenous antibiotics before implantation are well-recognized. Uncertainties have remained about the role of various preventive, diagnostic, and treatment measures such as skin antiseptics, pocket antibiotic solutions, antibacterial envelopes, prolonged antibiotics post-implantation, and others. When compared with previous guidelines or consensus statements, the present consensus document gives guidance on the use of novel device alternatives, novel oral anticoagulants, antibacterial envelopes, prolonged antibiotics post-implantation, as well as definitions on minimum quality requirements for centres and operators and volumes. The recognition that an international consensus document focused on management of CIED infections is lacking, the dissemination of results from new important randomized trials focusing on prevention of CIED infections, and observed divergences in managing device-related infections as found in an European Heart Rhythm Association worldwide survey, provided a strong incentive for a Novel 2019 International State-of-the-art Consensus document on risk assessment, prevention, diagnosis, and treatment of CIED infections.
|
|
7. |
|
|
8. |
|
|
9. |
|
|
10. |
- Gorenek, B, et al.
(författare)
-
Device-detected subclinical atrial tachyarrhythmias: definition, implications and management-an European Heart Rhythm Association (EHRA) consensus document, endorsed by Heart Rhythm Society (HRS), Asia Pacific Heart Rhythm Society (APHRS) and Sociedad Latinoamericana de Estimulación Cardíaca y Electrofisiología (SOLEACE)
- 2017
-
Ingår i: Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. - : Oxford University Press (OUP). - 1532-2092 .- 1099-5129. ; 19:9, s. 1556-1578
-
Tidskriftsartikel (refereegranskat)
|
|