SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Israelsson Marlen) "

Sökning: WFRF:(Israelsson Marlen)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bäcklund, Nils, et al. (författare)
  • Reference intervals of salivary cortisol and cortisone and their diagnostic accuracy in Cushing's syndrome
  • 2020
  • Ingår i: European Journal of Endocrinology. - : Bioscientifica. - 0804-4643 .- 1479-683X. ; 182:6, s. 569-582
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The challenge of diagnosing Cushing's syndrome (CS) calls for high precision biochemical screening. This study aimed to establish robust reference intervals for, and compare the diagnostic accuracy of, salivary cortisol and cortisone in late-night samples and after a low-dose (1 mg) dexamethasone suppression test (DST). Design and methods: Saliva samples were collected at 08:00 and 23:00 h, and at 08:00 h, after a DST, from 22 patients with CS and from 155 adult reference subjects. We also collected samples at 20:00 and 22:00 h from 78 of the reference subjects. Salivary cortisol and cortisone were analysed with liquid chromatography-tandem mass spectrometry. The reference intervals were calculated as the 2.5th and 97.5th percentiles of the reference population measurements. Diagnostic accuracies of different tests were compared, based on areas under the receiver-operating characteristic curves. Results: The upper reference limits of salivary cortisol and cortisone at 23:00 h were 3.6 nmol/L and 13.5 nmol/L, respectively. Using these reference limits, CS was detected with a sensitivity (95% CI) of 90% (70-99%) and specificity of 96% (91-98%) for cortisol, and a 100% (84-100%) sensitivity and 95% (90-98%) specificity for cortisone. After DST, cortisol and cortisone upper reference limits were 0.79 nmol/L and 3.5 nmol/L, respectively. CS was detected with 95% (75-100%) sensitivity and 96% (92-99%) specificity with cortisol, and 100% (83-100%) sensitivity and 94% (89-97%) specificity with cortisone. No differences in salivary cortisol or cortisone levels were found between samples collected at 22:00 and 23:00 h. Conclusion: Salivary cortisol and cortisone in late-night samples and after DST showed high accuracy for diagnosing CS, salivary cortisone being slightly, but significantly better. © 2020 European Society of Endocrinology Printed in Great Britain.
  •  
2.
  • Bäcklund, Nils, et al. (författare)
  • Reference intervals of salivary cortisol and cortisone and their diagnostic accuracy in Cushing’s syndrome
  • 2020
  • Ingår i: European Journal of Endocrinology. - : Bioscientifica. - 0804-4643 .- 1479-683X. ; 182:6, s. 569-582
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The challenge of diagnosing Cushing's syndrome (CS) calls for high precision biochemical screening. This study aimed to establish robust reference intervals for, and compare the diagnostic accuracy of, salivary cortisol and cortisone in late-night samples and after a low-dose (1 mg) dexamethasone suppression test (DST).Design and methods: Saliva samples were collected at 08:00 and 23:00 h, and at 08:00 h, after a DST, from 22 patients with CS and from 155 adult reference subjects. We also collected samples at 20:00 and 22:00 h from 78 of the reference subjects. Salivary cortisol and cortisone were analysed with liquid chromatography-tandem mass spectrometry. The reference intervals were calculated as the 2.5th and 97.5th percentiles of the reference population measurements. Diagnostic accuracies of different tests were compared, based on areas under the receiver-operating characteristic curves.Results: The upper reference limits of salivary cortisol and cortisone at 23:00 h were 3.6 nmol/L and 13.5 nmol/L, respectively. Using these reference limits, CS was detected with a sensitivity (95% CI) of 90% (70-99%) and specificity of 96% (91-98%) for cortisol, and a 100% (84-100%) sensitivity and 95% (90-98%) specificity for cortisone. After DST, cortisol and cortisone upper reference limits were 0.79 nmol/L and 3.5 nmol/L, respectively. CS was detected with 95% (75-100%) sensitivity and 96% (92-99%) specificity with cortisol, and 100% (83-100%) sensitivity and 94% (89-97%) specificity with cortisone. No differences in salivary cortisol or cortisone levels were found between samples collected at 22:00 and 23:00 h.Conclusion: Salivary cortisol and cortisone in late-night samples and after DST showed high accuracy for diagnosing CS, salivary cortisone being slightly, but significantly better.
  •  
3.
  • Israelsson, Marlen, et al. (författare)
  • 20α- and 20β-dihydrocortisone may interfere in LC-MS/MS determination of cortisol in saliva and urine
  • 2018
  • Ingår i: Annals of Clinical Biochemistry. - : Sage Publications. - 0004-5632 .- 1758-1001. ; 55:3, s. 341-347
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: LC-MS/MS methods offer high selectivity in cortisol determinations. However, endogenous steroid metabolites may still interfere and compromise the results, for example in the diagnosis of Cushing's syndrome. Erroneously elevated cortisol may, in particular, be misleading at the low concentrations found in salivary samples obtained at late night and after dexamethasone suppression.Methods: Interferences in our LC-MS/MS method used for determination of cortisol in saliva and urine were identified by comparing their retention times and mass spectra with those of pure candidate substances. The chromatographic conditions used in our LC-MS/MS method, including column and mobile phase gradient, were varied in order to separate the target compound from the interferences.Results: Two interferences, which were co-eluting or eluting close to cortisol in our original method, were successfully separated from cortisol by adjustment of the chromatographic conditions. These interferences were found in both urine and saliva and were identified as the two endogenous cortisol isomers 20- and 20-dihydrocortisone. The isomers share molecular mass and mass spectrometric fragmentation pattern with cortisol using electrospray ionization in the positive-ion mode. Both give rise to the transitions m/z 363.1>121.1, 363.1>115.1 and 363.1>97.1. In our original LC-MS/MS setup, the 20-dihydrocortisone co-eluted with cortisol in the chromatography step resulting in false high determinations.Conclusions: Cortisol determination by LC-MS/MS may suffer from erroneously elevated results unless 20- and 20-dihydrocortisone are chromatographically separated from cortisol.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy