SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sioris C.E.) "

Sökning: WFRF:(Sioris C.E.)

  • Resultat 1-10 av 14
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Brohede, Samuel, 1977, et al. (författare)
  • Validation of Odin/OSIRIS stratospheric NO2 profiles
  • 2007
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 112:D07310
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents the validation study of stratospheric NO2 profiles retrieved from Odin/OSIRIS measurements of limb-scattered sunlight (version 2.4). The Optical Spectrograph and Infrared Imager System (OSIRIS) NO2 data set is compared to coincident solar occultation measurements by the Halogen Occultation Experiment (HALOE), Stratospheric Aerosol and Gas Experiment (SAGE) II, SAGE III, and Polar Ozone and Aerosol Measurement (POAM) III during the 2002–2004 period. Comparisons with seven Systeme d'Analyse par Observation Zenithal (SAOZ) balloon measurements are also presented. All comparisons show good agreement, with differences, both random and systematic, of less than 20% between 25 km and 35 km. Inconsistencies with SAGE III below 25 km are found to be caused primarily by diurnal effects from varying NO2 concentrations along the SAGE III line-of-sight. On the basis of the differences, the OSIRIS random uncertainty is estimated to be 16% between 15 km and 25 km, 6% between 25 km and 35 km, and 9% between 35 km and 40 km. The estimated systematic uncertainty is about 22% between 15 and 25 km, 11–21% between 25 km and 35 km, and 11–31% between 35 km and 40 km. The uncertainties for AM (sunrise) profiles are generally largest and systematic deviations are found to be larger at equatorial latitudes. The results of this validation study show that the OSIRIS NO2 profiles are well behaved, with reasonable uncertainty estimates between 15 km and 40 km. This unique NO2 data set, with more than hemispheric coverage and high vertical resolution will be of particular interest for studies of nitrogen chemistry in the middle atmosphere, which is closely linked to ozone depletion.
  •  
2.
  • Carleer, M. R., et al. (författare)
  • Validation of water vapour profiles from the Atmospheric Chemistry Experiment (ACE)
  • 2008
  • Ingår i: Atmospheric Chemistry and Physics Discussion: An Interactive Open Access Journal of the European Geosciences Union. ; 8:2, s. 4499-4559
  • Tidskriftsartikel (refereegranskat)abstract
    • The Atmospheric Chemistry Experiment (ACE) mission was launched in August 2003 to sound the atmosphere by solar occultation. Water vapour (H2O), one of the most important molecules for climate and atmospheric chemistry, is one of the key species provided by the two principal instruments, the infrared Fourier Transform Spectrometer (ACE-FTS) and the MAESTRO UV-Visible spectrometer (ACE-MAESTRO). The first instrument performs measurements on several lines in the 1362–2137 cm−1 range, from which vertically resolved H2O concentration profiles are retrieved, from 7 to 90 km altitude. ACE-MAESTRO measures profiles using the water absorption band in the near infrared part of the spectrum at 926.0–969.7 nm. This paper presents a comprehensive validation of the ACE-FTS profiles. We have compared the H2O volume mixing ratio profiles with space-borne (SAGE II, HALOE, POAM III, MIPAS, SMR) observations and measurements from balloon-borne frostpoint hygrometers and a ground based lidar. We show that the ACE-FTS measurements provide H2O profiles with small retrieval uncertainties in the stratosphere (better than 5% from 15 to 70 km, gradually increasing above). The situation is unclear in the upper troposphere, due mainly to the high variability of the water vapour volume mixing ratio in this region. A new water vapour data product from the ACE-MAESTRO (Measurement of Aerosol Extinction in the Stratosphere and Troposphere Retrieved by Occultation) is also presented and initial comparisons with ACE-FTS are discussed.
  •  
3.
  • Randall, C. E., et al. (författare)
  • Stratospheric effects of energetic particle precipitation in 2003-2004
  • 2005
  • Ingår i: Geophysical Research Letters. - 1944-8007 .- 0094-8276. ; 32:5, s. 1-4
  • Tidskriftsartikel (refereegranskat)abstract
    • Upper stratospheric enhancements in NOx (NO and NO2) were observed at high northern latitudes from March through at least July of 2004. Multi-satellite data analysis is used to examine the temporal evolution of the enhancements, to place them in historical context, and to investigate their origin. The enhancements were a factor of 4 higher than nominal at some locations, and are unprecedented in the northern hemisphere since at least 1985. They were accompanied by reductions in O-3 of more than 60% in some cases. The analysis suggests that energetic particle precipitation led to substantial NOx production in the upper atmosphere beginning with the remarkable solar storms in late October 2003 and possibly persisting through January. Downward transport of the excess NOx, facilitated by unique meteorological conditions in 2004 that led to an unusually strong upper stratospheric vortex from late January through March, caused the enhancements.
  •  
4.
  • Bourassa, A. E., et al. (författare)
  • Fast NO2 retrievals from Odin-OSIRIS limb scatter measurements
  • 2011
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 4:5, s. 965-972
  • Tidskriftsartikel (refereegranskat)abstract
    • The feasibility of retrieving vertical profiles of NO2 from space-based measurements of limb scattered sunlight has been demonstrated using several different data sets since the 1980's. The NO2 data product routinely retrieved from measurements made by the Optical Spectrograph and InfraRed Imaging System (OSIRIS) instrument onboard the Odin satellite uses a spectral fitting technique over the 437 to 451 nm range, over which there are 36 individual wavelength measurements. In this work we present a proof of concept technique for the retrieval of NO2 using only 4 of the 36 OSIRIS measurements in this wavelength range, which reduces the computational cost by almost an order of magnitude. The method is an adaptation of a triplet analysis technique that is currently used for the OSIRIS retrievals of ozone at Chappuis band wavelengths. The results obtained are shown to be in very good agreement with the spectral fit method, and provide an important alternative for applications where the computational burden is very high. Additionally this provides a baseline for future instrument design in terms of cost effectiveness and reducing spectral range requirements.
  •  
5.
  • Brohede, Samuel, 1977, et al. (författare)
  • A stratospheric NO2 climatology from Odin/OSIRIS limb-scatter measurements
  • 2007
  • Ingår i: Canadian Journal of Physics. - 0008-4204 .- 1208-6045. ; 85:11, s. 1253-1274
  • Tidskriftsartikel (refereegranskat)abstract
    • A climatology of stratospheric nitrogen dioxide (NO2), in terms of mean and standard deviation, as a function of latitude (5° bins); altitude (10–46 km in 2 km bins); local solar time (24 h); and month is constructed based on the Odin/OSIRIS limb-scattering data from 2002–2005. The measured profiles, given at specific local solar times, are scaled to all 24 h using a photochemical box model. The Odin orbit gives near global coverage around the equinoxes and hemispheric coverage elsewhere, due to lack of sunlight. The mean NO2 field at a specific local solar time involves high concentrations in the polar summer, peaking at around 25 km, with a negative equatorward gradient. Distinct high levels between 40–50° latitude at 30 km in the winter/spring hemisphere are also found, associated with the so-called {Noxon-cliff}. The diurnal cycle reveals the lowest NO2 concentrations just after sunrise and steep gradients at twilight. The 1σ standard deviation is generally quite low, around 20%, except for winter and spring high latitudes, where values are well above 50% and stretch through the entire stratosphere, a phenomenon probably related to the polar vortex. It is also found that NO2 concentrations are log-normally distributed. Comparisons to a climatology based on data from a (REPROBUS) chemical transport model for the same time period reveal relative differences below 20% in general, which is comparable to the estimated OSIRIS systematic uncertainty. Clear exceptions are the polar regions in winter/spring throughout the atmosphere and equatorial regions below 25 km, where OSIRIS is relatively higher by 40% and more. These discrepancies are most likely attributable to limitations of the model, but this has to be investigated further.
  •  
6.
  •  
7.
  • Haley, C. S., et al. (författare)
  • Retrievals of stratospheric O3 and NO2 profiles from Odin Optical Spectrograph and InfraRed Imager System (OSIRIS) limb-scattered sunlight measurements
  • 2004
  • Ingår i: Journal of Geophysical Research. - 0148-0227 .- 2156-2202. ; 109:D16
  • Tidskriftsartikel (refereegranskat)abstract
    • Scientific studies of the major environmental questions of global warming and ozone depletion require global data sets of atmospheric constituents with relevant temporal and spatial resolution. In this paper global number density profiles of O3 and NO2 are retrieved from Odin/OSIRIS limb-scattered sunlight measurements, using the Maximum A Posteriori estimator. Differential Optical Absorption Spectroscopy is applied to OSIRIS radiances as an intermediate step, using the wavelength windows 571-617 nm for O3 and 435-451 nm for NO2. The method is computationally efficient for processing OSIRIS data on an operational basis. Results show that a 2-3 km height resolution is generally achievable between about 12 km and 45 km for O3 with an estimated accuracy of 13\% at the peak and between about 15 km and 40 km for NO2 with an estimated accuracy of 10\% at the peak. First validations of the retrieved data indicate a good agreement both with other retrieval techniques applied to OSIRIS measurements and with the results of other instruments. Once the validation has reached a confident level, the retrieved data will be used to study important stratospheric processes relevant to global environmental problems. The unique NO2 data set will be of particular interest for studies of nitrogen chemistry in the middle atmosphere.
  •  
8.
  • Khosrawi, F., et al. (författare)
  • The SPARC water vapour assessment II: Comparison of stratospheric and lower mesospheric water vapour time series observed from satellites
  • 2018
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 11:7, s. 4435-4463
  • Tidskriftsartikel (refereegranskat)abstract
    • Time series of stratospheric and lower mesospheric water vapour using 33 data sets from 15 different satellite instruments were compared in the framework of the second SPARC (Stratosphere-troposphere Processes And their Role in Climate) water vapour assessment (WAVAS-II). This comparison aimed to provide a comprehensive overview of the typical uncertainties in the observational database that can be considered in the future in observational and modelling studies, e.g addressing stratospheric water vapour trends. The time series comparisons are presented for the three latitude bands, the Antarctic (80°-70°S), the tropics (15°S-15°N) and the Northern Hemisphere mid-latitudes (50°-60°N) at four different altitudes (0.1, 3, 10 and 80hPa) covering the stratosphere and lower mesosphere. The combined temporal coverage of observations from the 15 satellite instruments allowed the consideration of the time period 1986-2014. In addition to the qualitative comparison of the time series, the agreement of the data sets is assessed quantitatively in the form of the spread (i.e. the difference between the maximum and minimum volume mixing ratios among the data sets), the (Pearson) correlation coefficient and the drift (i.e. linear changes of the difference between time series over time). Generally, good agreement between the time series was found in the middle stratosphere while larger differences were found in the lower mesosphere and near the tropopause. Concerning the latitude bands, the largest differences were found in the Antarctic while the best agreement was found for the tropics. From our assessment we find that most data sets can be considered in future observational and modelling studies, e.g. addressing stratospheric and lower mesospheric water vapour variability and trends, if data set specific characteristics (e.g. drift) and restrictions (e.g. temporal and spatial coverage) are taken into account.
  •  
9.
  • Kiefer, M., et al. (författare)
  • The SPARC water vapour assessment II: biases and drifts of water vapour satellite data records with respect to frost point hygrometer records
  • 2023
  • Ingår i: Atmospheric Measurement Techniques. - 1867-1381 .- 1867-8548. ; 16:19, s. 4589-4642
  • Tidskriftsartikel (refereegranskat)abstract
    • Satellite data records of stratospheric water vapour have been compared to balloon-borne frost point hygrometer (FP) profiles that are coincident in space and time. The satellite data records of 15 different instruments cover water vapour data available from January 2000 through December 2016. The hygrometer data are from 27 stations all over the world in the same period. For the comparison, real or constructed averaging kernels have been applied to the hygrometer profiles to adjust them to the measurement characteristics of the satellite instruments. For bias evaluation, we have compared satellite profiles averaged over the available temporal coverage to the means of coincident FP profiles for individual stations. For drift determinations, we analysed time series of relative differences between spatiotemporally coincident satellite and hygrometer profiles at individual stations. In a synopsis we have also calculated the mean biases and drifts (and their respective uncertainties) for each satellite record over all applicable hygrometer stations in three altitude ranges (10-30 hPa, 30-100 hPa, and 100 hPa to tropopause). Most of the satellite data have biases <10 % and average drifts <1 % yr-1 in at least one of the respective altitude ranges. Virtually all biases are significant in the sense that their uncertainty range in terms of twice the standard error of the mean does not include zero. Statistically significant drifts (95 % confidence) are detected for 35 % of the ≈ 1200 time series of relative differences between satellites and hygrometers.
  •  
10.
  • Lossow, S., et al. (författare)
  • The SPARC water vapour assessment II: comparison of annual, semi-annual and quasi-biennial variations in stratospheric and lower mesospheric water vapour observed from satellites
  • 2017
  • Ingår i: Atmospheric Measurement Techniques. - : Copernicus GmbH. - 1867-1381 .- 1867-8548. ; 10:3, s. 1111-1137
  • Tidskriftsartikel (refereegranskat)abstract
    • In the framework of the second SPARC (Stratosphere-troposphere Processes And their Role in Climate) water vapour assessment (WAVAS-II), the amplitudes and phases of the annual, semi-annual and quasi-biennial variation in stratospheric and lower mesospheric water were compared using 30 data sets from 13 different satellite instruments. These comparisons aimed to provide a comprehensive overview of the typical uncertainties in the observational database which can be considered in subsequent observational and modelling studies. For the amplitudes, a good agreement of their latitude and altitude distribution was found. Quantitatively there were differences in particular at high latitudes, close to the tropopause and in the lower mesosphere. In these regions, the standard deviation over all data sets typically exceeded 0.2 ppmv for the annual variation and 0.1 ppmv for the semi-annual and quasi-biennial variation. For the phase, larger differences between the data sets were found in the lower mesosphere. Generally the smallest phase uncertainties can be observed in regions where the amplitude of the variability is large. The standard deviations of the phases for all data sets were typically smaller than a month for the annual and semi-annual variation and smaller than 5 months for the quasi-biennial variation. The amplitude and phase differences among the data sets are caused by a combination of factors. In general, differences in the temporal variation of systematic errors and in the observational sampling play a dominant role. In addition, differences in the vertical resolution of the data, the considered time periods and influences of clouds, aerosols as well as non-local thermodynamic equilibrium (NLTE) effects cause differences between the individual data sets. .1 Symposia of COSPAR Scientific Commission A, held during the Thirty-first COSPAR Scientific Assembly
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 14

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy