SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Van Hamersveld Koen T.) "

Sökning: WFRF:(Van Hamersveld Koen T.)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hasan, Shaho, et al. (författare)
  • Late stabilization after initial migration in patients undergoing cemented total knee arthroplasty : a 5-year followup of 2 randomized controlled trials using radiostereometric analysis
  • 2022
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3682 .- 1745-3674. ; 93, s. 271-276
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: In total knee arthroplasty (TKA), metal-backed (MBT) and all-polyethylene (APT) designs have shown comparable implant migration up to 2 years postoperatively using radiostereometric analysis (RSA). However, studies comparing mid-term migration of both designs are lacking. Furthermore, continuously migrating TKAs up to 2 years may continue to migrate or stabilize thereafter. Therefore, we compared 5-year migration of MBT and APT using either cruciate-stabilizing (CS) or posteriorstabilizing (PS) designs and specifically assessed migration profiles of continuously migrating TKAs beyond 2 years. PATIENTS AND METHODS: The present study includes results from 2 randomized trials comparing migration of cemented MBT with APT of either CS (CS study, n = 59) or PS (PS study, n = 56) design. 2 surgeons performed all surgeries. We used a linear mixed model for the analyses. RESULTS: The overall migration between MBT and APT TKAs was similar for either the CS or PS design over a 5-year period. In both studies combined, 9 implants showed continuous migration in the second postoperative year, of which 1 (APT-CS) was revised for instability, 4 (2 MBT-CS, MBT-PS, APT-PS) stabilized, and 4 (2 MBT-CS, APT-CS, MBT-PS) lacked 5-year data. INTERPRETATION: Overall migration was similar between MBT and APT TKAs up to 5 years, for both the CS and PS design. 4 initially migrating TKAs stabilized between 2- and 5-year follow-up, stressing the need for longer-term followup to determine whether second-year continuous migration correctly predicts loosening.
  •  
2.
  • Hasan, Shaho, et al. (författare)
  • The Influence of Postoperative Coronal Alignment on Tibial Migration After Total Knee Arthroplasty in Preoperative Varus and Valgus Knees : A Secondary Analysis of 10 Randomized Controlled Trials Using Radiostereometric Analysis
  • 2021
  • Ingår i: The Journal of bone and joint surgery. American volume. - 1535-1386. ; 103:24, s. 2281-2290
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Orthopaedic surgeons aim for mechanical alignment when performing total knee arthroplasty (TKA) as malalignment is associated with loosening. Loosening may be predicted by migration as measured with radiostereometric analysis (RSA), but previous RSA studies on postoperative alignment have shown contradictory results and have been limited to cemented implants and small numbers of patients. Therefore, we performed a secondary analysis of 10 previously published randomized controlled trials (RCTs) to compare migration between postoperative in-range and out-of-range cemented and uncemented TKA implants among patients with a preoperative varus or valgus knee. METHODS: All RCTs involving the use of RSA that had been conducted at 2 centers were included. Alignment was classified, with use of the hip-knee-ankle angle (HKA), as in-range (0° ± 3°) or out-of-range (<-3° or >3°). The fixation methods included cemented, uncemented-coated, and uncemented-uncoated. Migration was measured at 3, 12, and 24 months. A linear mixed model was used, with adjustment for fixation method and clustering of patients within centers. RESULTS: Of 476 TKA implants that had been out-of-range preoperatively, 290 were in-range postoperatively and 186 were out-of-range in either varus (n = 143) or valgus (n = 43) postoperatively. The mean migration at 3, 12, and 24 months was 0.73 mm (95% confidence interval [CI], 0.66 to 0.79 mm), 0.92 mm (95% CI, 0.85 to 1.00 mm), and 0.97 mm (95% CI, 0.90 to 1.05 mm), respectively, for the in-range group and 0.80 mm (95% CI, 0.72 to 0.87 mm), 0.98 (95% CI, 0.90 to 1.07 mm), and 1.04 mm (95% CI, 0.95 to 1.13 mm), respectively, for the out-of-range group (p = 0.07). The fixation method significantly influenced migration, with uncemented-uncoated implants migrating more than cemented and uncemented-coated implants (p < 0.001). CONCLUSIONS: Postoperative alignment did not influence migration of TKAs in the first 2 postoperative years in patients with preoperative varus or valgus alignment of the knee. However, the fixation method significantly influenced migration, with uncemented-uncoated implants showing the greatest migration. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
  •  
3.
  • Van Hamersveld, Koen T., et al. (författare)
  • Migration of all-polyethylene compared with metal-backed tibial components in cemented total knee arthroplasty : A randomized controlled trial
  • 2018
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 89:4, s. 412-417
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose — With a rapidly increasing population in need of total knee arthroplasty (TKA), there is renewed interest in cost-saving all-polyethylene designs. Differences between metal-backed and all-polyethylene designs in initial component migration assessed by radiostereometric analysis (RSA), a proven predictor for late aseptic loosening, have been scantily reported. The purpose of this study was to compare implant migration and clinical outcomes of all-polyethylene tibial components versus metal-backed trays of similar geometrical shape. Patients and methods — In this randomized controlled trial, 59 patients received a cemented Triathlon condylar-stabilizing implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed tibial component (n = 30). RSA measurements and clinical scores (the Knee Society Score, Forgotten Joint Score, and Knee Osteoarthritis and Injury Outcome Score) were evaluated at baseline and postoperatively at 3, 12, and 24 months. A linear mixed-effects model was used to analyze the repeated measurements. Results — A statistically significant difference in mean migration after 2 years was found in favor of the all-polyethylene group, with a mean maximum total point motion of 0.61 mm (95% CI 0.49–0.74) versus 0.81 mm (95% CI 0.68–0.96) for the cemented group (p = 0.03). However, this difference was smaller and not statistically significant after post hoc adjustment for surgeon effect. Both groups showed comparable improvements on all clinical outcome scores over time. Interpretation — The Triathlon all-polyethylene tibial component showed less migration, suggesting a lower risk of late loosening as compared with its metal-backed counterpart. However, the found surgeon effect warrants further investigation.
  •  
4.
  • van Hamersveld, Koen T., et al. (författare)
  • Risk Factors for Tibial Component Loosening : A Meta-Analysis of Long-Term Follow-up Radiostereometric Analysis Data
  • 2021
  • Ingår i: Journal of Bone and Joint Surgery. American volume. - : NLM. - 0021-9355 .- 1535-1386. ; 103:12, s. 1115-1124
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Radiostereometric analysis (RSA) is a highly accurate tool to detect implant migration and predict loosening following total knee arthroplasty (TKA). However, little is known about the predisposing risk factors for implant migration, nor which migration profile should be considered physiological (i.e., merely part of an implant-settling phase) and which should be considered pathological (i.e., having a high probability for implant loosening). By pooling individual participant data from long-term follow-up RSA studies, we aimed to identify predisposing risk factors for tibial component loosening.METHODS: Individual data were collected for 630 patients from 11 RSA studies. The repeated measurements were analyzed with use of a linear mixed-effects model, determining the effect of age, sex, body mass index, diagnosis, preoperative and postoperative limb alignment, and prosthesis characteristics on tibial component migration over time, taking into account the clustering of patients within studies.RESULTS: High initial migration was found to result in early mechanical loosening in 18 cases (2.9%) and septic loosening in 2 cases (0.3%), whereas stabilization of high initial migration occurred in 17 cases (2.7%). Late loosening occurred in 13 cases (2.1%). All other 580 cases (92.1%) showed early stabilization and remained stable over time. Mixed-effects model analyses showed that for cemented prostheses, sex, diagnosis, and posterior cruciate ligament type had an effect on migration, but these differences were nonsignificant when analyzing migration from 3 months onwards. Uncemented prostheses aligned in varus showed more migration than neutrally and valgus-aligned TKAs (p = 0.031), and this difference increased over time (p < 0.001). Significantly higher migration was observed following uncemented TKA without an osseointegration-promoting surface (p < 0.001).CONCLUSIONS: For cemented prostheses, increased migration during the first 3 postoperative months was observed for female patients, patients with rheumatoid arthritis, and patients who underwent a posterior-stabilized TKA. For uncemented prostheses, both postoperative varus alignment of the lower limb and the absence of an osseointegration-promoting surface significantly increased postoperative tibial component migration.LEVEL OF EVIDENCE: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.
  •  
5.
  • van Hamersveld, Koen T., et al. (författare)
  • Marker-based versus model-based radiostereometric analysis of total knee arthroplasty migration : a reanalysis with comparable mean outcomes despite distinct types of measurement error
  • 2019
  • Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 90:4, s. 366-372
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose — Pooling data of studies evaluating total knee arthroplasty migration using radiostereometric analysis (RSA) may be compromised when the RSA method used would influence estimated differences between groups. We therefore reanalyzed a marker-based RSA study with model-based RSA to assess possible limitations of each RSA method, including insert micromotions in modular TKA and their effect on estimated group differences. Patients and methods — All patients had received a cemented Triathlon implant (Stryker, Mahwah, NJ, USA) with either an all-polyethylene (n = 29) or a metal-backed (n = 28) tibial component. The latter group was reanalyzed with model-based RSA. Precision of each RSA method was calculated using double examinations. Bland–Altman plots were constructed to determine the limits of agreement between the 2 RSA methods. Polyethylene insert micromotion was quantified by measuring migration with respect to the metal tray. Finally, analyses of the original study were repeated with the model-based RSA results. Results — Systematic differences were found in translations between marker-based and model-based RSA as a result of different reference origins being used for migration calculations. Micromotions of the polyethylene insert within the metal tray were negligibly small. Mean migration results were comparable between marker-based and model-based RSA when using the same reference origin, even though conclusions on individual patients may differ between RSA methods due to various types of measurement error (e.g., marker occlusion and model-fit inaccuracies). Interpretation — At least for the studied TKA design, pooling mean migration data of different RSA methods appears justified. For translations, however, adjustments should be made to correct for differences in reference origin. Migration patterns of individual patients may differ as a result of distinct types of measurement error.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy