SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Abe Y) "

Sökning: WFRF:(Abe Y)

  • Resultat 31-40 av 127
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
31.
  • Sumi, T., et al. (författare)
  • The first Neptune analog or super-earth with a Neptune-like orbit : MOA-2013-BLG-605LB
  • 2016
  • Ingår i: Astrophysical Journal. - 0004-637X. ; 825:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present the discovery of the first Neptune analog exoplanet or super-Earth with a Neptune-like orbit, MOA-2013-BLG-605Lb. This planet has a mass similar to that of Neptune or a super-Earth and it orbits at 9 ∼ 14 times the expected position of the snow line, a snow, which is similar to Neptune's separation of 11 a snow from the Sun. The planet/host-star mass ratio is q = (3.6 ± 0.7) × 10-4 and the projected separation normalized by the Einstein radius is s = 2.39 ± 0.05. There are three degenerate physical solutions and two of these are due to a new type of degeneracy in the microlensing parallax parameters, which we designate "the wide degeneracy." The three models have (i) a Neptune-mass planet with a mass of Mp = 21-7 +6M⊕ orbiting a low-mass M-dwarf with a mass of Mh = 0.19-0.06 +0.05M⊙, (ii) a mini-Neptune with Mp = 7.9-1.2 +1.8M⊕ orbiting a brown dwarf host with Mh = 0.068-0.011 +0.019M⊙, and (iii) a super-Earth with Mp = 3.2-0.3 +0.5MM⊕ orbiting a low-mass brown dwarf host with Mh = 0.025-0.0004 +0.005M⊙, which is slightly favored. The 3D planet-host separations are 4.6-1.2 +4.7au, 2.1-0.2 +1.0au, and 0.94-0.02 +0.67au, which are 8.9-1.4 +10.5, 12-1 +7, or 14-1 +11 times larger than a snow for these models, respectively. Keck adaptive optics observations confirm that the lens is faint. This discovery suggests that low-mass planets with Neptune-like orbits are common. Therefore processes similar to the one that formed Neptune in our own solar system or cold super-Earths may be common in other solar systems.
  •  
32.
  •  
33.
  •  
34.
  •  
35.
  • Aprile, E., et al. (författare)
  • An approximate likelihood for nuclear recoil searches with XENON1T data
  • 2022
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 82:11
  • Tidskriftsartikel (refereegranskat)abstract
    • The XENON collaboration has published stringent limits on specific dark matter – nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 t-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihood and therefore most statistical results for any nuclear recoil spectrum. Computing approximate results with this method is approximately three orders of magnitude faster than the likelihood used in the original publications of XENON1T, where limits were set for specific families of recoil spectra. Using this same method, we include toy Monte Carlo simulation-derived binwise likelihoods for the upcoming XENONnT experiment that can similarly be used to assess the sensitivity to arbitrary nuclear recoil signatures in its eventual 20 t-year exposure.
  •  
36.
  • Aprile, E., et al. (författare)
  • Application and modeling of an online distillation method to reduce krypton and argon in XENON1T
  • 2022
  • Ingår i: Progress of Theoretical and Experimental Physics. - : Oxford University Press (OUP). - 2050-3911. ; 2022:5
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of (360 +/- 60) ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fitted to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low-energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation liquid xenon time projection chamber experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large-scale detectors.
  •  
37.
  • Aprile, E., et al. (författare)
  • Effective Field Theory and Inelastic Dark Matter Results from XENON1T
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • In this work we expand on the XENON1T nuclear recoil searches and study the individual signals of Dark Matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) as well as a model of inelastic Dark Matter using data from the two science runs of the detector totalling 1 tonne*year exposure. For these analyses we extended the region of interest from [4.9, 40.9]keVnr to [4.9, 54.4]keVnr to enhance our sensitivity for signals that peak at nonzero energies. We show that the data is consistent with a background only hypothesis, with small excesses in the models which peak between 20 and 50keVnr, obtaining a maximum local discovery significance of 1.7 for the VVs ChEFT model for a WIMP mass of 70GeV/c2, and 1.8 for an iDM particle of 50GeV/c2 with a mass splitting of 100keV/c2. For each model we report 90% confidence level upper limits. We also report limits on three benchmark models of WIMP interaction using ChEFT for which we investigate the effect of isospin breaking interactions, reporting up to 6 orders of magnitude weaker limits with respect to the isospin conserving case driven by cancellations in the expected rate.
  •  
38.
  • Aprile, E., et al. (författare)
  • Emission of single and few electrons in XENON1T and limits on light dark matter
  • 2022
  • Ingår i: Physical Review D. - 2470-0010 .- 2470-0029. ; 106:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates <30 events/(electron×kg×day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.
  •  
39.
  • Aprile, E., et al. (författare)
  • Material radiopurity control in the XENONnT experiment
  • 2022
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 82:7
  • Tidskriftsartikel (refereegranskat)abstract
    • The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background (∼∼17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222Rn activity concentration in XENONnT is determined to be 4.2 (+0.5−0.7) μBq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.
  •  
40.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 31-40 av 127
Typ av publikation
tidskriftsartikel (114)
konferensbidrag (4)
forskningsöversikt (4)
rapport (1)
annan publikation (1)
Typ av innehåll
refereegranskat (114)
övrigt vetenskapligt/konstnärligt (10)
Författare/redaktör
Abe, Y (21)
Abe, K. (17)
Wang, Z. (16)
Stein, DJ (16)
Brem, S (16)
Piras, F (16)
visa fler...
Spalletta, G (16)
Brown, A. (15)
Benedetti, F (15)
Jahanshad, N (15)
Kwon, JS (15)
Lochner, C (15)
Thompson, PM (15)
Venkatasubramanian, ... (15)
van den Heuvel, OA (15)
Yun, JY (15)
Koch, K. (14)
Abe, S. (14)
Abe, M (14)
Bollettini, I (14)
Gruner, P (14)
Lazaro, L (14)
Marsh, R (14)
Mataix-Cols, D (14)
Menchon, JM (14)
Nakamae, T (14)
Soriano-Mas, C (14)
Itow, Y. (13)
Abe, T. (13)
Boedhoe, PSW (13)
Hoexter, MQ (13)
Narayanaswamy, JC (13)
Simpson, HB (13)
Soreni, N (13)
van Wingen, GA (13)
Denys, D (12)
Ameis, SH (12)
Arnold, PD (12)
Batistuzzo, MC (12)
Beucke, JC (12)
Cheng, YQ (12)
Dallaspezia, S (12)
Hu, H (12)
Huyser, C (12)
Kaufmann, C (12)
Martinez-Zalacain, I (12)
Nakao, T (12)
Reddy, YCJ (12)
Schmaal, L (12)
Walitza, S (12)
visa färre...
Lärosäte
Karolinska Institutet (63)
Stockholms universitet (30)
Uppsala universitet (13)
Lunds universitet (11)
Göteborgs universitet (9)
Linköpings universitet (8)
visa fler...
Kungliga Tekniska Högskolan (6)
Umeå universitet (4)
Luleå tekniska universitet (4)
Chalmers tekniska högskola (4)
Linnéuniversitetet (2)
Sveriges Lantbruksuniversitet (1)
visa färre...
Språk
Engelska (127)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (50)
Medicin och hälsovetenskap (21)
Teknik (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy