SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Auricchio Angelo) "

Search: WFRF:(Auricchio Angelo)

  • Result 31-40 of 45
Sort/group result
   
EnumerationReferenceCoverFind
31.
  • Nof, Eyal, et al. (author)
  • Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal : an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry
  • 2019
  • In: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 21:12, s. 1876-1889
  • Journal article (peer-reviewed)abstract
    • AIMS: The present study sought to determine predictors for success and outcomes of patients who underwent cardiac implantable electronic devices (CIED) extraction indicated for systemic or local CIED related infection in particular where complete lead removal could not be achieved.METHODS AND RESULTS: ESC-EORP ELECTRa (European Lead Extraction ConTRolled Registry) is a European prospective lead extraction registry. Out of the total cohort, 1865/3510 (52.5%) patients underwent removal due to CIED related infection. Predictors and outcomes of failure were analysed. Complete removal was achieved in 1743 (93.5%) patients, partial (<4 cm of lead left) in 88 (4.7%), and failed (>4 cm of lead left) in 32 (1.8%) patients. Removal success was unrelated to type of CIED infection (pocket or systemic). Predictors for failure were older leads and older patients [odds ratio (OR) 1.14 (1.08-1.19), P < 0.0001 and OR 2.68 (1.22-5.91), P = 0.0146, respectively]. In analysis by lead, predictors for failure were: pacemaker vs. defibrillator removal and failure to engage the locking stylet all the way to the tip [OR 0.20 (0.04-0.95), P = 0.03 and OR 0.32 (0.13-0.74), P = 0.008, respectively]. Significantly higher complication rates were noted in the failure group (40.6% vs. 15.9 for partial and 8.7% for success groups, P < 0.0001). Failure to remove a lead was a strong predictor for in hospital mortality [hazard ratio of 2.05 (1.01-4.16), P = 0.046].CONCLUSION: A total of 6.5% of infected CIED patients failed attempted extraction. Only were >4 cm of lead remained resulted in higher procedural complications and mortality rates.
  •  
32.
  • Normand, Camilla, et al. (author)
  • Cardiac resynchronization therapy pacemaker or cardiac resynchronization therapy defibrillator : what determines the choice?-findings from the ESC CRT Survey II
  • 2019
  • In: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:6, s. 918-927
  • Journal article (peer-reviewed)abstract
    • AIMS: The decision to implant a cardiac resynchronization therapy pacemaker (CRT-P) or a cardiac resynchronization therapy defibrillator (CRT-D) may be challenging. There are no clear guideline recommendations as no randomized study of cardiac resynchronization therapy (CRT) has been designed to compare the effects of CRT-P with those of CRT-D on patients' outcomes. In the CRT Survey II, we studied patient and implantation centre characteristics associated with the choice of CRT-P vs. CRT-D.METHODS AND RESULTS: Clinical practice data from 10 692 patients undergoing CRT implantation of whom 7467 (70%) patients received a CRT-D and 3225 (30%) received a CRT-P across 42 ESC countries were collected and analysed between October 2015 and January 2017. Factors favouring the selection of CRT-P implantation included age >75 years, female gender, non-ischaemic heart failure (HF) aetiology, New York Heart Association functional Class III/IV symptoms, left ventricular ejection fraction >25%, atrial fibrillation, atrioventricular (AV) block II/III, and implantation in a university hospital.CONCLUSION: In a large cohort from the CRT Survey II, we found that patients allocated to receive CRT-P exhibited particular phenotypes with more symptomatic HF, more frequent comorbidities, advanced age, female gender, non-ischaemic HF aetiology, atrial fibrillation, and evidence of AV block. There were substantial differences in the proportion of patients allocated to receive CRT-P vs. CRT-D between countries.
  •  
33.
  • Polewczyk, Anna, et al. (author)
  • Transvenous lead extraction procedures in women based on ESC-EHRA EORP European Lead Extraction ConTRolled ELECTRa registry : is female sex a predictor of complications?
  • 2019
  • In: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:12
  • Journal article (peer-reviewed)abstract
    • AIMS: Female sex is considered an independent risk factor of transvenous leads extraction (TLE) procedure. The aim of the study was to evaluate the effectiveness of TLE in women compared with men.METHODS AND RESULTS: A post hoc analysis of risk factors and effectiveness of TLE in women and men included in the ESC-EHRA EORP ELECTRa registry was conducted. The rate of major complications was 1.96% in women vs. 0.71% in men; P = 0.0025. The number of leads was higher in men (mean 1.89 vs. 1.71; P < 0.0001) with higher number of abandoned leads in women (46.04% vs. 34.82%; P < 0.0001). Risk factors of TLE differed between the sexes, of which the major were: signs and symptoms of venous occlusion [odds ratio (OR) 3.730, confidence interval (CI) 1.401-9.934; P = 0.0084], cumulative leads dwell time (OR 1.044, CI 1.024-1.065; P < 0.001), number of generator replacements (OR 1.029, CI 1.005-1.054; P = 0.0184) in females and the number of leads (OR 6.053, CI 2.422-15.129; P = 0.0001), use of powered sheaths (OR 2.742, CI 1.404-5.355; P = 0.0031), and white blood cell count (OR 1.138, CI 1.069-1.212; P < 0.001) in males. Individual radiological and clinical success of TLE was 96.29% and 98.14% in women compared with 98.03% and 99.21% in men (P = 0.0046 and 0.0098).CONCLUSION: The efficacy of TLE was lower in females than males, with a higher rate of periprocedural major complications. The reasons for this difference are probably related to disparities in risk factors in women, including more pronounced leads adherence to the walls of the veins and myocardium. Lead management may be key to the effectiveness of TLE in females.
  •  
34.
  •  
35.
  • Regoli, François, et al. (author)
  • Impact of anticoagulation therapy on outcomes in patients with cardiac implantable resynchronization devices undergoing transvenous lead extraction : A substudy of the ESC-EHRA EORP ELECTRa (European Lead Extraction ConTRolled) Registry
  • 2019
  • In: Cardiovascular Electrophysiology. - : Wiley. - 1045-3873 .- 1540-8167. ; 30:7, s. 1086-1095
  • Journal article (peer-reviewed)abstract
    • INTRODUCTION: Little data are available on anticoagulation (AC) management in patients with cardiac resynchronization (CRT) devices who undergo transvenous lead extraction (TLE) procedure. We investigated the impact of AC on periprocedural complications in CRT patients undergoing TLE, enrolled in the ESC-EHRA European Lead Extraction ConTrolled (ELECTRa) registry.METHODS AND RESULTS: All CRT patients treated with TLE enrolled in the registry were considered. Perioperative AC management was left to the discretion of the Center. Major and minor intraprocedural and postprocedural complications were compared between patients without AC (Gp1) and patients with AC (Gp2). Regression analyses were performed to identify predictors of complications for Gp2. Out of 734 CRT pts, 328 (44.7%) were under AC (Gp2). Patients from Gp2 presented lower LVEF (Gp2 32.5 ± 10.9 vs Gp1 34.5 ± 11.9%; P = 0.03), more advanced heart failure disease (NYHA III/IV: Gp2 42.0 vs Gp1 31.5%; P = 0.02), and renal impairment (Gp2 39.0 vs Gp1 24.3%; P < 0.001). Perioperative regimens included AC interruption (Gp2A: n = 169, 51.5%), "bridging" (Gp2B: n = 135, 41.2%), or continued AC (Gp2C: n = 24, 7.3%). TLE complete success rates (98% in both groups) and major complication rates were comparable for both groups; minor bleeding events were more frequent in Gp2 (5.5%) compared to Gp1 (2.5%; P = 0.051). No independent predictors were identified for Gp2, but minor complications were associated with "bridging" approach (Gp2B: 16 events vs Gp2A/C: 9 events; P = 0.020).CONCLUSION: CRT patients treated with TLE under AC were more compromised but did not present more major complications compared to patients without AC. More minor complications were associated with "bridging" AC regimen.
  •  
36.
  • Segreti, Luca, et al. (author)
  • Procedural outcomes associated with transvenous lead extraction in patients with abandoned leads : an ESC-EHRA ELECTRa (European Lead Extraction ConTRolled) Registry Sub-Analysis.
  • 2019
  • In: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 21:4, s. 645-654
  • Journal article (peer-reviewed)abstract
    • Aims: The decision to abandon or extract superfluous leads remains controversial. We sought to compare procedural outcome of patients with and without abandoned leads undergoing transvenous lead extraction (TLE).Methods and results: An analysis of the ESC-EHRA European Lead Extraction ConTRolled ELECTRa registry was conducted. Patients were stratified into two groups based on the presence (Group 1) or absence (Group 2) of abandoned leads at the time for extraction. Out of 3508 TLE procedures, 422 patients (12.0%) had abandoned leads (Group 1). Group 1 patients were older and more likely to have implantable cardioverter-defibrillator devices, infection indication (78.8% vs. 49.8%), and vegetations (24.6% vs. 15.3%). Oldest lead dwelling time was longer in Group 1 (10.9 vs. 6.3 years) as was the number of extracted leads per patient (3.2 vs. 1.7). Manual traction failure (94.5% vs. 78.8%), powered sheath use (50.7% vs. 28.4%), and femoral approach were higher in Group 1 (P < 0.0001). Procedural success rate and clinical success (89.8% vs. 96.6%, P < 0.0001) were lower in Group 1. Major complication including deaths (5.5% vs. 2.3%, P = 0.0007) and procedure related major complications (3.3% vs. 1.4%, P = 0.0123) were higher in Group 1. The presence of abandoned leads at the time of TLE was an independent predictor of clinical failure [odds ratio (OR) 2.31, confidence interval (CI) 1.57-3.40] and complications [OR 1.69, CI 1.22-2.35]. receiver-operating characteristic curve analysis showed a dwell time threshold of 9 years for radiological failure and major complications.Conclusions: Previously abandoned leads at the time of TLE were associated with increased procedural complexity, clinical failure, and major complication, which may have important implications for future studies regarding managing of lead failures.
  •  
37.
  • Sidhu, Baldeep S., et al. (author)
  • Risk stratification of patients undergoing transvenous lead extraction with the ELECTRa Registry Outcome Score (EROS) : an ESC EHRA EORP European lead extraction ConTRolled ELECTRa registry analysis
  • 2021
  • In: Europace. - : Oxford University Press. - 1099-5129 .- 1532-2092. ; 23:9, s. 1462-1471
  • Journal article (peer-reviewed)abstract
    • AIMS: Transvenous lead extraction is associated with a significant risk of complications and identifying patients at highest risk pre-procedurally will enable interventions to be planned accordingly. We developed the ELECTRa Registry Outcome Score (EROS) and applied it to the ELECTRa registry to determine if it could appropriately risk-stratify patients.METHODS AND RESULTS: EROS was devised to risk-stratify patients into low risk (EROS 1), intermediate risk (EROS 2), and high risk (EROS 3). This was applied to the ESC EORP European Lead Extraction ConTRolled ELECTRa registry; 57.5% EROS 1, 31.8% EROS 2, and 10.7% EROS 3. Patients with EROS 3 or 2 were significantly more likely to require powered sheaths and a femoral approach to complete procedures. Patients with EROS 3 were more likely to suffer procedure-related major complications including deaths (5.1 vs. 1.3%; P < 0.0001), both intra-procedural (3.5 vs. 0.8%; P = 0.0001) and post-procedural (1.6 vs. 0.5%; P = 0.0192). They were more likely to suffer post-procedural deaths (0.8 vs. 0.2%; P 0.0449), cardiac avulsion or tear (3.8 vs. 0.5%; P < 0.0001), and cardiovascular lesions requiring pericardiocentesis, chest tube, or surgical repair (4.6 vs. 1.0%; P < 0.0001). EROS 3 was associated with procedure-related major complications including deaths [odds ratio (OR) 3.333, 95% confidence interval (CI) 1.879-5.914; P < 0.0001] and all-cause in-hospital major complications including deaths (OR 2.339, 95% CI 1.439-3.803; P = 0.0006).CONCLUSION: EROS successfully identified patients who were at increased risk of significant procedural complications that require urgent surgical intervention.
  •  
38.
  • Sidhu, Baldeep S., et al. (author)
  • The effect of centre volume and procedure location on major complications and mortality from transvenous lead extraction : an ESC EHRA EORP European Lead Extraction ConTRolled ELECTRa registry subanalysis
  • 2020
  • In: Europace. - : Oxford University Press (OUP). - 1099-5129 .- 1532-2092. ; 22:11, s. 1718-1728
  • Journal article (peer-reviewed)abstract
    • AIMS : Transvenous lead extraction (TLE) should ideally be undertaken by experienced operators in a setting that allows urgent surgical intervention. In this analysis of the ELECTRa registry, we sought to determine whether there was a significant difference in procedure complications and mortality depending on centre volume and extraction location.METHODS AND RESULTS : Analysis of the ESC EORP European Lead Extraction ConTRolled ELECTRa registry was conducted. Low-volume (LoV) centres were defined as <30 procedures/year, and high-volume (HiV) centres as ≥30 procedures/year. Three thousand, two hundred, and forty-nine patients underwent TLE by a primary operator cardiologist; 17.1% in LoV centres and 82.9% in HiV centres. Procedures performed by primary operator cardiologists in LoV centres were less likely to be successful (93.5% vs. 97.1%; P < 0.0001) and more likely to be complicated by procedure-related deaths (1.1% vs. 0.4%; P = 0.0417). Transvenous lead extraction undertaken by primary operator cardiologists in LoV centres were associated with increased procedure-related major complications including death (odds ratio 1.858, 95% confidence interval 1.007-3.427; P = 0.0475). Transvenous lead extraction locations varied; 52.0% operating room, 9.5% hybrid theatre and 38.5% catheterization laboratory. Rates of procedure-related major complications, including death occurring in a high-risk environment (combining operating room and hybrid theatre), were similar to those undertaken in the catheterization laboratory (1.7% vs. 1.6%; P = 0.9297).CONCLUSION : Primary operator cardiologists in LoV centres are more likely to have extractions complicated by procedure-related deaths. There was no significant difference in procedure complications between different extraction settings. These findings support the need for TLE to be performed in experienced centres with appropriate personnel present.
  •  
39.
  •  
40.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 31-40 of 45
Type of publication
journal article (41)
research review (4)
Type of content
peer-reviewed (42)
other academic/artistic (3)
Author/Editor
Auricchio, Angelo (45)
Blomström-Lundqvist, ... (25)
Deharo, Jean-Claude (16)
Linde, Cecilia (14)
Dickstein, Kenneth (14)
Bongiorni, Maria Gra ... (14)
show more...
Kennergren, Charles (13)
Vardas, Panos E (12)
Butter, Christian (12)
Leclercq, Christophe (11)
Filippatos, Gerasimo ... (11)
Maggioni, Aldo P. (11)
Kuck, Karl-Heinz (11)
Kutarski, Andrzej (11)
Brignole, Michele (11)
Dean, Veronica (10)
Lip, Gregory Y H (10)
Rinaldi, Christopher ... (10)
Sechtem, Udo (10)
Funck-Brentano, Chri ... (10)
Vahanian, Alec (10)
Bax, Jeroen (10)
Boriani, Giuseppe (9)
Cleland, John (9)
Tendera, Michal (8)
Widimsky, Petr (8)
Zamorano, Jose Luis (7)
Gasparini, Maurizio (7)
Kirchhof, Paulus (7)
Popescu, Bogdan A. (7)
Kolh, Philippe (6)
Delgado, Victoria (6)
McDonagh, Theresa (6)
Ponikowski, Piotr (6)
Glikson, Michael (6)
De Caterina, Raffael ... (6)
Merkely, Bela (6)
Laroche, Cecile (6)
Reiner, Zeljko (6)
Mont, Lluis (6)
Heidbuchel, Hein (6)
Oto, Ali (6)
Israel, Carsten W (6)
Sutton, Richard (6)
Camm, John (6)
Ceconi, Claudio (6)
Le Heuzey, Jean-Yves (6)
Sirnes, Per Anton (6)
Crijns, Harry (6)
Daubert, Jean-Claude (6)
show less...
University
Uppsala University (34)
Linköping University (7)
Karolinska Institutet (7)
Lund University (3)
University of Gothenburg (2)
Linnaeus University (1)
Language
English (43)
Polish (1)
Portuguese (1)
Research subject (UKÄ/SCB)
Medical and Health Sciences (27)
Engineering and Technology (1)

Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view