SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Axelsson Jan 1966 ) "

Sökning: WFRF:(Axelsson Jan 1966 )

  • Resultat 31-40 av 80
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
31.
  • Brynolfsson, Patrik, et al. (författare)
  • Technical note : adapting a GE SIGNA PET/MR scanner for radiotherapy
  • 2018
  • Ingår i: Medical physics (Lancaster). - : Wiley-Blackwell Publishing Inc.. - 0094-2405. ; 45:8, s. 3546-3550
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Simultaneous collection of PET and MR data for radiotherapy purposes are useful for, for example, target definition and dose escalations. However, a prerequisite for using PET/MR in the radiotherapy workflow is the ability to image the patient in treatment position. The aim of this work was to adapt a GE SIGNA PET/MR scanner to image patients for radiotherapy treatment planning and evaluate the impact on signal-to-noise (SNR) of the MR images, and the accuracy of the PET attenuation correction. Method: A flat tabletop and a coil holder were developed to image patients in the treatment position, avoid patient contour deformation, and facilitate attenuation correction of flex coils. Attenuation corrections for the developed hardware and an anterior array flex coil were also measured and implemented to the PET/MR system to minimize PET quantitation errors. The reduction of SNR in the MR images due to the added distance between the coils and the patient was evaluated using a large homogenous saline-doped water phantom, and the activity quantitation errors in PET imaging were evaluated with and without the developed attenuation corrections. Result: We showed that the activity quantitation errors in PET imaging were within ±5% when correcting for attenuation of the flat tabletop, coil holder, and flex coil. The SNR of the MRI images were reduced to 74% using the tabletop, and 66% using the tabletop and coil holders. Conclusion: We present a tabletop and coil holder for an anterior array coil to be used with a GE SIGNA PET/MR scanner, for scanning patients in the radiotherapy work flow. Implementing attenuation correction of the added hardware from the radiotherapy setup leads to acceptable PET image quantitation. The drop in SNR in MR images may require adjustment of the imaging protocols.
  •  
32.
  • Cedernaes, Jonathan, et al. (författare)
  • Short Sleep Makes Declarative Memories Vulnerable to Stress in Humans
  • 2015
  • Ingår i: Sleep. - : Oxford University Press (OUP). - 0161-8105 .- 1550-9109. ; 38:12, s. 1861-1868
  • Tidskriftsartikel (refereegranskat)abstract
    • Study Objective: This study sought to investigate the role of nocturnal sleep duration for the retrieval of oversleep consolidated memories, both prior to and after being cognitively stressed for similar to 30 minutes the next morning. Design: Participants learned object locations (declarative memory task comprising 15 card pairs) and a finger tapping sequence (procedural memory task comprising 5 digits) in the evening. After learning, participants either had a sleep opportunity of 8 hours (between similar to 23:00 and similar to 07:00, full sleep condition) or they could sleep between similar to 03:00 and similar to 07:00 (short sleep condition). Retrieval of both memory tasks was tested in the morning after each sleep condition, both before (similar to 08:30) and after being stressed (similar to 09:50). Setting: Sleep laboratory. Participants: 15 healthy young men. Results: The analyses demonstrated that oversleep memory changes did not differ between sleep conditions. However, in their short sleep condition, following stress hallmarked by increased subjective stress feelings, the men were unable to maintain their pre-stress performance on the declarative memory task, whereas their performance on the procedural memory task remained unchanged. While men felt comparably subjectively stressed by the stress intervention, overall no differences between pre- and post-stress recalls were observed following a full night of sleep. Conclusions: The findings suggest that 8-h sleep duration, within the range recommended by the US National Sleep Foundation, may not only help consolidate newly learned procedural and declarative memories, but also ensure full access to both during periods of subjective stress.
  •  
33.
  • Censoni, Luciano, et al. (författare)
  • Verification of multi-structure targeting in chronic microelectrode brain recordings from CT scans
  • 2022
  • Ingår i: Journal of Neuroscience Methods. - : Elsevier. - 0165-0270 .- 1872-678X. ; 382
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Large-scale microelectrode recordings offer a unique opportunity to study neurophysiological processes at the network level with single cell resolution. However, in the small brains of many experimental animals, it is often technically challenging to verify the correct targeting of the intended structures, which inherently limits the reproducibility of acquired data.New method: To mitigate this problem, we have developed a method to programmatically segment the trajectory of electrodes arranged in larger arrays from acquired CT-images and thereby determine the position of individual recording tips with high spatial resolution, while also allowing for coregistration with an anatomical atlas, without pre-processing of the animal samples or post-imaging histological analyses.Results: Testing the technical limitations of the developed method, we found that the choice of scanning angle influences the achievable spatial resolution due to shadowing effects caused by the electrodes. However, under optimal acquisition conditions, individual electrode tip locations within arrays with 250 µm inter-electrode spacing were possible to reliably determine.Comparison to existing methods: Comparison to a histological verification method suggested that, under conditions where individual wires are possible to track in slices, a 90% correspondence could be achieved in terms of the number of electrodes groups that could be reliably assigned to the same anatomical structure.Conclusions: The herein reported semi-automated procedure to verify anatomical targeting of brain structures in the rodent brain could help increasing the quality and reproducibility of acquired neurophysiological data by reducing the risk of assigning recorded brain activity to incorrectly identified anatomical locations.
  •  
34.
  • Constantinescu, Clara, 1995, et al. (författare)
  • Persons with suspicious onset of multiple sclerosis but with undetermined diagnosis had persistent lower cognition and reduced quality of life
  • 2021
  • Ingår i: Multiple Sclerosis and Related Disorders. - : Elsevier BV. - 2211-0348. ; 52
  • Tidskriftsartikel (refereegranskat)abstract
    • Backgound: Differential diagnosis of multiple sclerosis (MS) includes a variety of disorders and misdiagnosis is common. Objective: To follow-up persons with suspected onset of MS but in whom the diagnostic investigation was negative. Methods: In a prospective study including 271 persons with clinical features of suspected MS onset, 136 persons were diagnosed with MS or clinically isolated syndrome (PwMS), 46 had other disorders, and 89 persons had a negative diagnostic work-up, i.e. persons with undetermined diagnosis (PwUD). They underwent diagnostic reassessment, and those who remained without a diagnosis were investigated for signs of pathology including cognitive tests and assessments of quality of life (QoL). Results were compared with those of PwMS and 24 age and sex matched healthy controls (HC). Results: After reassement 55 (20%) persons still had undetermined diagnosis (PwUD). They had similar age and gender distribution as PwMS. In 76% of PwUD, the suspected clinical onset included sensory symptoms. PwUD and PwMS scored similarly in cognitive tests and QoL but significantly lower than HC. At 3 years follow-up, PwMS and PwUD improved in most test parameters, but PwUD scored lower than PwMS in cognition. Conclusion: PwUD constituted the dominating differential diagnosis in persons with suspected clinical onset of MS. QoL and cognition were comparable with those of PwMS but significantly lower than in HC.
  •  
35.
  • Giacobbo, B., et al. (författare)
  • The Aged Striatum : Evidence of Molecular and Structural Changes Using a Longitudinal Multimodal Approach in Mice
  • 2022
  • Ingår i: Frontiers in Aging Neuroscience. - : Frontiers Media S.A.. - 1663-4365. ; 14
  • Tidskriftsartikel (refereegranskat)abstract
    • To study the aging human brain requires significant resources and time. Thus, mice models of aging can provide insight into changes in brain biological functions at a fraction of the time when compared to humans. This study aims to explore changes in dopamine D1 and D2 receptor availability and of gray matter density in striatum during aging in mice and to evaluate whether longitudinal imaging in mice may serve as a model for normal brain aging to complement cross-sectional research in humans. Mice underwent repeated structural magnetic resonance imaging (sMRI), and [11C]Raclopride and [11C]SCH23390 positron emission tomography (PET) was performed on a subset of aging mice. PET and sMRI data were analyzed by binding potential (BP ND ), voxel- and tensor-based morphometry (VBM and TBM, respectively). Longitudinal PET revealed a significant reduction in striatal BP ND for D2 receptors over time, whereas no significant change was found for D1 receptors. sMRI indicated a significant increase in modulated gray matter density (mGMD) over time in striatum, with limited clusters showing decreased mGMD. Mouse [11C]Raclopride data is compatible with previous reports in human cross-sectional studies, suggesting that a natural loss of dopaminergic D2 receptors in striatum can be assessed in mice, reflecting estimates from humans. No changes in D1 were found, which may be attributed to altered [11C]SCH23390 kinetics in anesthetized mice, suggesting that this tracer is not yet able to replicate human findings. sMRI revealed a significant increase in mGMD. Although contrary to expectations, this increase in modulated GM density may be attributed to an age-related increase in non-neuronal cells.
  •  
36.
  • Grefve, Josefine, et al. (författare)
  • Histopathology-validated gross tumor volume delineations of intraprostatic lesions using PSMA-positron emission tomography/multiparametric magnetic resonance imaging
  • 2024
  • Ingår i: Physics and Imaging in Radiation Oncology. - : Elsevier. - 2405-6316. ; 31
  • Tidskriftsartikel (refereegranskat)abstract
    • Background and purpose: Dose escalation in external radiotherapy of prostate cancer shows promising results in terms of biochemical disease-free survival. Boost volume delineation guidelines are sparse which may cause high interobserver variability. The aim of this research was to characterize gross tumor volume (GTV) delineations based on multiparametric magnetic resonance imaging (mpMRI) and prostate specific membrane antigen-positron emission tomography (PSMA-PET) in relation to histopathology-validated Gleason grade 4 and 5 regions.Material and methods: The study participants were examined with [68Ga]PSMA-PET/mpMRI prior to radical prostatectomy. Four radiation oncologists delineated GTVs in 15 study participants, on four different image types; T2-weighted (T2w), diffusion weighted imaging (DWI), dynamic contrast enhanced (DCE) and PSMA-PET scans separately. The simultaneous truth and performance level estimation (STAPLE) algorithm was used to generate combined GTVs. GTVs were subsequently compared to histopathology. We analysed how Dice similarity coefficient (DSC) and lesion coverage are affected by using single versus multiple image types as well as by adding a clinical target volume (CTV) margin.Results: Median DSC (STAPLE) for different GTVs varied between 0.33 and 0.52. GTVPSMA-PET/mpMRI generated the highest median lesion coverage at 0.66. Combining different image types achieved similar lesion coverage as adding a CTV margin to contours from a single image type, while reducing non-malignant tissue inclusion within the target volume.Conclusion: The combined use of mpMRI or PSMA-PET/mpMRI shows promise, achieving higher DSC and lesion coverage while minimizing non-malignant tissue inclusion, in comparison to the use of a single image type with an added CTV margin.
  •  
37.
  • Hird, Emily J., et al. (författare)
  • Dopamine and reward-related vigor in younger and older adults
  • 2022
  • Ingår i: Neurobiology of Aging. - : Elsevier. - 0197-4580 .- 1558-1497. ; 118, s. 34-43
  • Tidskriftsartikel (refereegranskat)abstract
    • Vigor reflects how motivated people are to respond to stimuli. We previously showed that, on average, humans are more vigorous when a higher rate of reward is available, and that this relationship is modulated by the dopamine precursor levodopa. Dopamine signaling and probabilistic reward learning deteriorate across the adult life span, and thus, the relationship between vigor and reward may also change in aging. We tested this assertion and assessed whether it correlates with D1 dopamine receptor availability, measured using Positron Emission Tomography. We registered response times of 30 older and 30 younger participants during an oddball discrimination task where rewards varied systematically between trials. The average reward rate had a similar impact on vigor in both age groups. There was a weak positive association between ventral striatal dopamine receptor availability and the effect of average reward rate on response time. Overall, the effect of reward on response vigor was similar in younger and older adults, and weakly correlated with dopamine D1 receptor availability.
  •  
38.
  • Holmberg, Daniel, et al. (författare)
  • Reducing scanning time to 50% for In-111 pentetreotide SPECT when using model-based compensation
  • 2012
  • Ingår i: 2012 IEEE nuclear science symposium and medical imaging conference record (NSS/MIC). - : IEEE. - 9781467320306 - 9781467320283 ; , s. 2946-2949
  • Konferensbidrag (refereegranskat)abstract
    • In In-111-pentetreotide SPECT, it can be difficult to detect small tumors because of high noise levels and low spatial resolution. The aim of this study was to perform optimization of tumor detection in the liver, with regards to the acquisition and reconstruction protocol for In-111-pentetreotide SPECT with model-based compensation included in the OSEM reconstruction. We were also interested in the effect of performing the examination in half of the time or with half the administered activity. Image reconstruction without model-based compensation was also included for comparison. The study concentrates on the acquired number of projections and the subset size in the OSEM reconstruction, and evaluates contrast as a function of noise for a range of OSEM iterations. The raw-data projections are produced using Monte Carlo simulations of a patient-like anthropomorphic phantom with realistic In-111 pentetreotide uptake, including spherical tumors in the liver. Two collimators are evaluated, the extended low-energy general-purpose (ELEGP) and the medium-energy general-purpose (MEGP) collimator. ELEGP proved to be a better collimator when using model-based compensation. The results also indicate that a relatively low number of subsets is advantageous, and that 60 projection angles or even lower is a better choice than 120. For both collimators the time-reduced scan including model-based compensation was better compared to the full-time reconstructions without model-based compensation.
  •  
39.
  • Jakobson Mo, Susanna, Medicine Doktor, 1968-, et al. (författare)
  • Validation of dynamic [18F]FE-PE2I PET for estimation of relative regional cerebral blood flow : a comparison with [15O]H2O PET
  • 2022
  • Ingår i: EJNMMI Research. - : Springer Science+Business Media B.V.. - 2191-219X. ; 12:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Dopamine transporter (DAT) imaging is used in the diagnostic work-up in suspected parkinsonian syndromes and dementia with Lewy bodies but cannot differentiate between these syndromes, and an extra brain imaging examination of the regional cerebral blood flow (rCBF) or glucose metabolism is often needed for differential diagnosis. The requirement of two different imaging examinations is resource-consuming and inconvenient for the patients. Therefore, imaging of both cortical blood flow and DAT imaging with the same radiotracer would be more convenient and cost-effective. The aim of this study was to test whether relative regional cerebral blood flow (rCBFR) can be measured with the DAT-specific positron emission tomography (PET) tracer [18F]FE-PE2I (FE-PE2I), by validation with cerebral perfusion measured with [15O]H2O PET (H2O).Methods: The rCBFR was quantified by kinetic modeling for FE-PE2I (R1) and H2O (F). The R1 was calculated using the simplified reference tissue model, and F was calculated with a modified Koopman double-integration method. The linear relationship and intraclass correlation (ICC) between R1 and F were tested in image data derived from 29 patients with recent onset parkinsonism and 30 healthy controls.Results: There was a strong linear correlation across all subjects between R1 and F in the frontal, parietal, temporal, cingulate and occipital cortex as well as in the striatum (r ≥ 0.731–0.905, p < 0.001) with a good-to-excellent ICC, ranging from 0.727 to 0.943 (p < 0.001).Conclusions: Our results suggest that FE-PE2I may be used as a proxy for cerebral perfusion, thus potentially serving as a radiotracer for assessment of both DAT availability and rCBFR in one single dynamic scan. This could be valuable in the differential diagnosis of parkinsonian syndromes.Trial registration: EUDRA-CT 2015-003045-26. Registered 23 October 2015 https://www.clinicaltrialsregister.eu/ctr-search/search?query=2015-003045-26
  •  
40.
  • Jakobson Mo, Susanna, et al. (författare)
  • VNTR polymorphism in the SLC6A3 gene does not influence dopamine transporter availability measured by [18F]FE-PE2I PET or [123I]FP-Cit SPECT
  • 2022
  • Ingår i: Nuclear medicine communications. - : Wolters Kluwer. - 0143-3636 .- 1473-5628. ; 43:3, s. 247-255
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVE: To investigate the potential impact of polymorphism in the 3'-untranslated region (3'UTR) of the SLC6A3 gene (DAT1) on normal variation in dopamine transporter (DAT) imaging with [18F]FE-PE2I PET and [123I]FP-Cit SPECT.METHODS: Thirty-six individuals (mean age 70.4±5.4 years) with normal [18F]FE-PE2I PET and [123I]FP-Cit SPECT were genotyped for variable number of tandem repeats (VNTR) in the 3′UTR of the DAT1 gene. The DAT-availability in the caudate and putamen as measured with [18F]FE-PE2I PET and [123I]FP-Cit SPECT, as well as in the substantia nigra with [18F]FE-PE2I PET were compared between the participants carrying one or two 9-repeat alleles (i.e. 9R+10R or 9R+9R; 47%) and the participants without a 9R allele (i.e. 10R+10R or 10R+11R; 53%). Nonparametric tests, linear regression analysis and mixed model analysis were used to assess any statistical difference in measured DAT availability between the two allele groups.RESULTS: The measured DAT-availability in PET- and SPECT-imaging tended to be slightly higher in the 9R-group; however, the difference did not reach statistical significance in either the caudate or the putamen or the substantia nigra. Instead, age did have a significant effect on the DAT level (P < 0.05) notwithstanding the genotype.CONCLUSION: No significant effect of DAT1-genotype was detectable in imaging with [18F]FE-PE2I PET or [123I]FP-Cit, instead, age accounted for the normal variation in DAT-PET and DAT-SPECT.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 31-40 av 80
Typ av publikation
tidskriftsartikel (68)
konferensbidrag (5)
annan publikation (3)
doktorsavhandling (3)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (68)
övrigt vetenskapligt/konstnärligt (12)
Författare/redaktör
Axelsson, Jan, 1966- (67)
Riklund, Katrine, MD ... (26)
Nyberg, Lars, 1966- (20)
Andersson, Micael (13)
Bäckman, Lars (13)
Karalija, Nina, 1984 ... (12)
visa fler...
Lindenberger, Ulman (12)
Johansson, Jarkko (12)
Riklund, Katrine (11)
Papenberg, Goran (11)
Nyholm, Tufve (10)
Rieckmann, Anna (10)
Salami, Alireza (10)
Jonsson, Joakim, 198 ... (10)
Wåhlin, Anders (9)
Blomqvist, Lennart (9)
Larsson, Anne (8)
Thellenberg-Karlsson ... (8)
Guitart-Masip, Marc (7)
Widmark, Anders (7)
Strandberg, Sara, 19 ... (7)
Sandgren, Kristina (7)
Bergh, Anders (6)
Ericsson, Madelene (6)
Lövdén, Martin (6)
af Bjerkén, Sara (5)
Nilsson, Erik (5)
Ögren, Margareta (5)
Söderkvist, Karin (5)
Jonasson, Lars S., 1 ... (5)
Strandberg, Sara (4)
de Boer, Lieke (4)
Backman, Lars (4)
Palmqvist, Richard (4)
Brynolfsson, Patrik (4)
Grill, Filip (4)
Jakobson Mo, Susanna (4)
Varrone, Andrea (4)
Sundström, Torbjörn (4)
Grefve, Josefine (4)
Lycke, Jan, 1956 (3)
Suhr, Ole B. (3)
Zackrisson, Björn (3)
Lubberink, Mark (3)
Pilebro, Björn (3)
Rutegård, Martin, 19 ... (3)
Jonasson, Lars, 1983 ... (3)
Lövdén, Martin, 1972 ... (3)
Leffler, Klara, 1988 ... (3)
Garzón, Benjamín (3)
visa färre...
Lärosäte
Umeå universitet (70)
Karolinska Institutet (34)
Stockholms universitet (14)
Göteborgs universitet (13)
Uppsala universitet (7)
Lunds universitet (4)
visa fler...
Örebro universitet (3)
Linköpings universitet (3)
Högskolan Väst (1)
Jönköping University (1)
visa färre...
Språk
Engelska (79)
Svenska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (73)
Teknik (7)
Naturvetenskap (5)
Samhällsvetenskap (4)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy