SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Lubberink M) "

Sökning: WFRF:(Lubberink M)

  • Resultat 51-60 av 62
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
51.
  • Sousa, Joao M., 1989-, et al. (författare)
  • Composite attenuation correction method using a 68Ge-transmission multi-atlas for quantitative brain PET/MR.
  • 2022
  • Ingår i: Physica medica (Testo stampato). - : Elsevier. - 1120-1797 .- 1724-191X. ; 97, s. 36-43
  • Tidskriftsartikel (refereegranskat)abstract
    • In positron emission tomography (PET), 68Ge-transmission scanning is considered the gold standard in attenuation correction (AC) though not available in current dual imaging systems. In this experimental study we evaluated a novel AC method for PET/magnetic resonance (MR) imaging which is essentially based on a composite database of multiple 68Ge-transmission maps and T1-weighted (T1w) MR image-pairs (composite transmission, CTR-AC). This proof-of-concept study used retrospectively a database with 125 pairs of co-registered 68Ge-AC maps and T1w MR images from anatomical normal subjects and a validation dataset comprising dynamic [11C]PE2I PET data from nine patients with Parkinsonism. CTR-AC maps were generated by non-rigid image registration of all database T1w MRI to each subject's T1w, applying the same transformation to every 68Ge-AC map, and averaging the resulting 68Ge-AC maps. [11C]PE2I PET images were reconstructed using CTR-AC and a patient-specific 68Ge-AC map as the reference standard. Standardized uptake values (SUV) and quantitative parameters of kinetic analysis were compared, i.e., relative delivery (R1) and non-displaceable binding potential (BPND). CTR-AC showed high accuracy for whole-brain SUV (mean %bias ± SD: 0.5 ± 3.5%), whole-brain R1 (-0.1 ± 3.2%), and putamen BPND (3.7 ± 8.1%). SUV and R1 precision (SD of %bias) were modest and lowest in the anterior cortex, with an R1 %bias of -1.1 ± 6.4%). The prototype CTR-AC is capable of providing accurate MRAC-maps with continuous linear attenuation coefficients though still experimental. The method's accuracy is comparable to the best MRAC methods published so far, both in SUV and as found for ZTE-AC in quantitative parameters of kinetic modelling.
  •  
52.
  • Sousa, João M., et al. (författare)
  • Evaluation of zero-echo-time attenuation correction for integrated PET/MR brain imaging-comparison to head atlas and 68Ge-transmission-based attenuation correction
  • 2018
  • Ingår i: EJNMMI Physics. - : Springer Science and Business Media LLC. - 2197-7364. ; 5:20
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: MRI does not offer a direct method to obtain attenuation correction maps as its predecessors (stand-alone PET and PET/CT), and bone visualisation is particularly challenging. Recently, zero-echo-time (ZTE) was suggested for MR-based attenuation correction (AC). The aim of this work was to evaluate ZTE- and atlas-AC by comparison to 68Ge-transmission scan-based AC.Nine patients underwent brain PET/MR and stand-alone PET scanning using the dopamine transporter ligand 11C-PE2I. For each of them, two AC maps were obtained from the MR images: an atlas-based, obtained from T1-weighted LAVA-FLEX imaging with cortical bone inserted using a CT-based atlas, and an AC map generated from proton-density-weighted ZTE images. Stand-alone PET 68Ge-transmission AC map was used as gold standard. PET images were reconstructed using the three AC methods and standardised uptake value (SUV) values for the striatal, limbic and cortical regions, as well as the cerebellum (VOIs) were compared. SUV ratio (SUVR) values normalised for the cerebellum were also assessed. Bias, precision and agreement were calculated; statistical significance was evaluated using Wilcoxon matched-pairs signed-rank test.Results: Both ZTE- and atlas-AC showed a similar bias of 6–8% in SUV values across the regions. Correlation coefficients with 68Ge-AC were consistently high for ZTE-AC (r 0.99 for all regions), whereas they were lower for atlas-AC, varying from 0.99 in the striatum to 0.88 in the posterior cortical regions. SUVR showed an overall bias of 2.9 and 0.5% for atlas-AC and ZTE-AC, respectively. Correlations with 68Ge-AC were higher for ZTE-AC, varying from 0.99 in the striatum to 0.96 in the limbic regions, compared to atlas-AC (0.99 striatum to 0.77 posterior cortex).Conclusions: Absolute SUV values showed less variability for ZTE-AC than for atlas-AC when compared to 68Ge-AC, but bias was similar for both methods. This bias is largely caused by higher linear attenuation coefficients in atlas- and ZTE-AC image compared to 68Ge-images. For SUVR, bias was lower when using ZTE-AC than for atlas-AC. ZTE-AC shows to be a more robust technique than atlas-AC in terms of both intra- and inter-patient variability.
  •  
53.
  •  
54.
  • Timmer, Stefan A J, et al. (författare)
  • Carriers of the hypertrophic cardiomyopathy MYBPC3 mutation are characterized by reduced myocardial efficiency in the absence of hypertrophy and microvascular dysfunction
  • 2011
  • Ingår i: European Journal of Heart Failure. - : Wiley. - 1388-9842 .- 1879-0844. ; 13:12, s. 1283-1289
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS:Next to left ventricular (LV) hypertrophy, hypertrophic cardiomyopathy (HCM) is characterized by microvascular dysfunction and reduced myocardial external efficiency (MEE). Insights into the presence of these abnormalities as early markers of disease are of clinical importance in risk stratification, and development of therapeutic approaches. Therefore, the aim was to investigate myocardial perfusion and energetics in genotype-positive, phenotype-negative HCM subjects (carriers).METHODS AND RESULTS:Fifteen carriers of an MYBPC3 mutation underwent [15O]water positron emission tomography (PET) to assess myocardial blood flow (MBF). [11C]acetate PET was performed to obtain myocardial oxygen consumption (MVO2). By use of cardiovascular magnetic resonance imaging, LV volumes and mass were defined to calculate MEE, i.e. the ratio between external work and MVO2. Eleven healthy, genotype-negative, family relatives underwent similar scanning protocols to serve as a control group. Left ventricular mass was comparable between carriers and controls (93 ± 25 vs. 99 ± 21 g, P= 0.85), as was MBF at rest (1.19 ± 0.34 vs. 1.18 ± 0.32 mL min−1 g−1, P= 0.92), and during hyperaemia (3.87 ± 0.75 vs. 3.96 ± 0.86 mL min−1 g−1, P= 0.77). Myocardial oxygen consumption averaged 0.137 ± 0.057 mL min−1 g−1 in carriers and was not significantly different from controls (0.125 ± 0.043 mL min−1 g−1, P= 0.29). Cardiac work, however, was slightly reduced in carriers (7398 ± 1384 vs. 9139 ± 2484 mmHg mL in controls, P= 0.08). As a consequence, MEE was significantly decreased in carriers (27 ± 10 vs. 36 ± 8% in controls, P= 0.02).CONCLUSION:Carriers display reduced myocardial work generation in relation to oxygen consumption, in the absence of hypertrophy and flow abnormalities. Hence, impaired myocardial energetics may constitute a primary component of HCM pathogenesis.
  •  
55.
  • Timmer, Stefan A J, et al. (författare)
  • Effects of alcohol septal ablation on coronary microvascular function and myocardial energetics in hypertrophic obstructive cardiomyopathy
  • 2011
  • Ingår i: American Journal of Physiology. Heart and Circulatory Physiology. - : American Physiological Society. - 0363-6135 .- 1522-1539. ; 301:1, s. H129-H137
  • Tidskriftsartikel (refereegranskat)abstract
    • This study investigated the effects of alcohol septal ablation (ASA) on microcirculatory function and myocardial energetics in patients with hypertrophic cardiomyopathy (HCM) and left ventricular outflow tract (LVOT) obstruction. In 15 HCM patients who underwent ASA, echocardiography was performed before and 6 mo after the procedure to assess the LVOT gradient (LVOTG). Additionally, [15O]water PET was performed to obtain resting myocardial blood flow (MBF) and coronary vasodilator reserve (CVR). Changes in LV mass (LVM) and volumes were assessed by cardiovascular magnetic resonance imaging. Myocardial oxygen consumption (MVVo2) was evaluated by [11C]acetate PET in a subset of seven patients to calculate myocardial external efficiency (MEE). After ASA, peak LVOTG decreased from 41 ± 32 to 23 ± 19 mmHg (P = 0.04), as well as LVM (215 ± 74 to 169 ± 63 g; P < 0.001). MBF remained unchanged (0.94 ± 0.23 to 0.98 ± 0.15 ml·min−1·g−1; P = 0.45), whereas CVR increased (2.55 ± 1.23 to 3.05 ± 1.24; P = 0.05). Preoperatively, the endo-to-epicardial MBF ratio was lower during hyperemia compared with rest (0.80 ± 0.18 vs. 1.18 ± 0.15; P < 0.001). After ASA, the endo-to-epicardial hyperemic (h)MBF ratio increased to 1.03 ± 0.26 (P = 0.02). ΔCVR was correlated to ΔLVOTG (r = −0.82; P < 0.001) and ΔLVM (r = −0.54; P = 0.04). MEE increased from 15 ± 6 to 20 ± 9% (P = 0.04). Coronary microvascular dysfunction in obstructive HCM is at least in part reversible by relief of LVOT obstruction. After ASA, hMBF and CVR increased predominantly in the subendocardium. The improvement in CVR was closely correlated to the absolute reduction in peak LVOTG, suggesting a pronounced effect of LV loading conditions on microvascular function of the subendocardium. Furthermore, ASA has favorable effects on myocardial energetics.
  •  
56.
  • Timmer, Stefan A J, et al. (författare)
  • Relation of coronary microvascular dysfunction in hypertrophic cardiomyopathy to contractile dysfunction independent from myocardial injury
  • 2011
  • Ingår i: American Journal of Cardiology. - : Elsevier BV. - 0002-9149 .- 1879-1913. ; 107:10, s. 1522-1528
  • Tidskriftsartikel (refereegranskat)abstract
    • We studied the spatial relations among hyperemic myocardial blood flow (hMBF), contractile function, and morphologic tissue alterations in 19 patients with hypertrophic cardiomyopathy (HC). All patients were studied with oxygen-15 water positron emission tomography during rest and adenosine administration to assess myocardial perfusion. Cardiovascular magnetic resonance was performed to derive delayed contrast-enhanced images and to calculate contractile function (Ecc) with tissue tagging. Eleven healthy subjects underwent similar positron emission tomographic and cardiovascular magnetic resonance scanning protocols and served as a control group. In the HC group, hMBF averaged 2.46 ± 0.91 ml/min/g and mean Ecc was −14.7 ± 3.4%, which were decreased compared to the control group (3.97 ± 1.48 ml/min/g and −17.7 ± 3.2%, respectively, p <0.001 for the 2 comparisons). Delayed contrast enhancement (DCE) was present only in patients with HC, averaging 6.2 ± 10.3% of left ventricular mass. In the HC group, Ecc and DCE in the septum (−13.7 ± 3.6% and 10.2 ± 13.6%) significantly differed from the lateral wall (−16.0 ± 2.8% and 2.4 ± 5.9%, p <0.001 for the 2 comparisons). In general, hMBF and Ecc were decreased in segments displaying DCE compared to nonenhanced segments (p <0.001 for the comparisons). In the HC group, univariate analysis revealed relations of hMBF to Ecc (r = −0.45, p <0.001) and DCE (r = −0.31, p <0.001). Multivariate analysis revealed that Ecc was independently related to hMBF (beta −0.37, p <0.001) and DCE (beta 0.28, p <0.001). In conclusion, in HC hMBF is impaired and related to contractile function independent from presence of DCE. When present, DCE reflected a progressed disease state as characterized by an increased perfusion deficit and contractile dysfunction.
  •  
57.
  • Timmer, S A J, et al. (författare)
  • Right ventricular energetics in patients with hypertrophic cardiomyopathy and the effect of alcohol septal ablation
  • 2011
  • Ingår i: Journal of Cardiac Failure. - : Elsevier BV. - 1071-9164 .- 1532-8414. ; 17:10, s. 827-831
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Diastolic dysfunction in hypertrophic cardiomyopathy (HCM) is accompanied by augmented left ventricular (LV) end-diastolic pressure, above all in the presence of LV outflow tract (LVOT) obstruction. Increased back-pressure may augment right ventricular (RV) afterload and induce an oxidative metabolic imbalance between the 2 ventricles. The aim was to study right-to-left ventricular oxidative metabolism in HCM and the effects of alcohol septal ablation (ASA).METHODS AND RESULTS:Twenty-one HCM patients were enrolled. Eleven healthy subjects served as a control group. Subjects underwent 2-dimensional echocardiography to assess LVOT gradient, left atrial size, and diastolic function. [11C]Acetate positron-emission tomography (PET) was performed to determine RVk2 and LVk2, as a noninvasive index of oxidative metabolism. Seven HCM patients with LVOT obstruction, scheduled to undergo ASA, were also studied 6 months after the procedure. RVk2 was higher in HCM patients than i control subjects (0.081 ± 0.021 min−1 vs. 0.061 ± 0.017 min−1; P = .05), whereas LVk2 was similar between groups. Consequently, RVk2/LVk2 was increased in the patients (0.85 ± 0.19 vs 0.59 ± 0.13; P = .004). In patients with obstructive HCM, ASA reduced RVk2 (0.085 ± 0.021 min−1 to 0.072 ± 0.022 min−1; P = .001). Inasmuch as LVk2 remained unaffected by the procedure, RVk2/LVk2 was decreased after ASA (0.66 ± 0.18; P = .03). The absolute change in LVOT gradient was related to the absolute change in RVk2 (r = 0.77; P = .044).CONCLUSIONS:In HCM patients, RV oxygen consumption is increased in relation to the LV. ASA reduces RV oxygen consumption in HCM patients with LVOT obstruction, suggesting that increased LV loading conditions and diastolic dysfunction play a predominant role in augmenting RV workload in these patients.
  •  
58.
  •  
59.
  • van der Veldt, Astrid A M, et al. (författare)
  • Quantitative Parametric Perfusion Images Using 15O-Labeled Water and a Clinical PET/CT Scanner : test-retest variability in lung cancer
  • 2010
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 51:11, s. 1684-1690
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantification of tumor perfusion using radioactive water (H215O) and PET is a promising method for monitoring treatment with antiangiogenic agents. However, use of dynamic H215O scans together with a fully 3-dimensional clinical PET/CT scanner needs to be validated. The purpose of the present study was to assess validity and reproducibility of dynamic H215O PET/CT scans for measuring tumor perfusion and validate the quantitative accuracy of parametric perfusion images.Methods:Eleven patients with non–small cell lung cancer were included in this study. Patients underwent 2 dynamic H215O (370 MBq) PET scans on the same day. During the first scan, arterial blood was withdrawn continuously. Input functions were derived from blood sampler data and the ascending aorta as seen in the images themselves (image-derived input function [IDIF]). Parametric perfusion images were computed using a basis function implementation of the standard single-tissue-compartment model. Volumes of interest (VOIs) were delineated on low-dose CT (LD-CT) and parametric perfusion images.Results:VOIs could be accurately delineated on both LD-CT and parametric perfusion images. These parametric perfusion images had excellent image quality and quantitative accuracy when compared with perfusion values determined by nonlinear regression. Good correlation between perfusion values derived from the blood sampler input function and IDIF was found (Pearson correlation coefficient, r = 0.964; P < 0.001). Test–retest variability of tumor perfusion was 16% and 20% when delineated on LD-CT and parametric perfusion images, respectively.Conclusion:The use of ascending aorta IDIFs is an accurate alternative to arterial blood sampling for quantification of tumor perfusion. Image quality obtained with a clinical PET/CT scanner enables generation of accurate parametric perfusion images. VOIs delineated on LD-CT have the highest reproducibility, and changes of more than 16% in tumor perfusion are likely to represent treatment effects.
  •  
60.
  • van der Vos, Charlotte S, et al. (författare)
  • Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
  • 2017
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 44:Suppl 1, s. S4-S16
  • Forskningsöversikt (refereegranskat)abstract
    • In recent years, there have been multiple advances in positron emission tomography/computed tomography (PET/CT) that improve cancer imaging. The present generation of PET/CT scanners introduces new hardware, software, and acquisition methods. This review describes these new developments, which include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent (18)F-fluorodeoxyglucose (FDG) activity. Also, hardware developments such as continuous bed motion (CBM), (digital) solid-state photodetectors and combined PET and magnetic resonance (MR) systems are explained. These novel techniques have a significant impact on cancer imaging, as they result in better image quality, improved small lesion detectability, and more accurate quantification of radiopharmaceutical uptake. This influences cancer diagnosis and staging, as well as therapy response monitoring and radiotherapy planning. Finally, the possible impact of these developments on the European Association of Nuclear Medicine (EANM) guidelines and EANM Research Ltd. (EARL) accreditation for FDG-PET/CT tumor imaging is discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 51-60 av 62
Typ av publikation
tidskriftsartikel (47)
konferensbidrag (10)
forskningsöversikt (2)
annan publikation (1)
doktorsavhandling (1)
recension (1)
visa fler...
visa färre...
Typ av innehåll
refereegranskat (43)
övrigt vetenskapligt/konstnärligt (18)
populärvet., debatt m.m. (1)
Författare/redaktör
Lubberink, Mark (51)
Lammertsma, Adriaan ... (18)
Appel, Lieuwe (13)
Lubberink, M (10)
Ahlström, Håkan, 195 ... (8)
Furmark, Tomas (7)
visa fler...
Engström, Mathias (7)
Smit, Egbert F (7)
Windhorst, Albert D (7)
Antoni, Gunnar (6)
Fredrikson, Mats (6)
Nyholm, Dag (6)
van der Veldt, Astri ... (6)
Boellaard, Ronald (6)
Jonasson, M (6)
Frick, Andreas (5)
Åhs, Fredrik (5)
Jonasson, My (5)
Schuit, Robert C (5)
Hendrikse, N Harry (5)
van Rossum, Albert C ... (5)
Knaapen, Paul (5)
Sousa, Joao M., 1989 ... (5)
Sorensen, J (4)
Gaemperli, Oliver (4)
Alaie, Iman (4)
Dweck, Marc R. (4)
Habib, Gilbert (4)
Kero, Tanja (4)
Postmus, Pieter E (4)
Gimelli, Alessia (4)
Gheysens, Olivier (4)
Glaudemans, Andor W ... (4)
Saraste, Antti (4)
Slart, Riemer H J A (4)
van Berckel, Bart N. ... (4)
Hoekstra, Otto S. (4)
Papadimitriou, Sterg ... (4)
Hyafil, Fabien (4)
von Knorring, Lars (3)
Scheltens, Philip (3)
Engman, Jonas (3)
Yaqub, Maqsood (3)
Appel, L. (3)
Ten Berg, Jurrien M (3)
Eriksson, Jonas (3)
Harms, H J (3)
Bucerius, Jan (3)
Frans, Örjan (3)
Knaapen, P. (3)
visa färre...
Lärosäte
Uppsala universitet (55)
Karolinska Institutet (13)
Mittuniversitetet (3)
Göteborgs universitet (1)
Stockholms universitet (1)
Linköpings universitet (1)
Språk
Engelska (62)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (35)
Samhällsvetenskap (8)
Teknik (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy