SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Mancuso N) "

Sökning: WFRF:(Mancuso N)

  • Resultat 21-30 av 66
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  • Paciaroni, M., et al. (författare)
  • Early Recurrence and Major Bleeding in Patients With Acute Ischemic Stroke and Atrial Fibrillation Treated With Non-Vitamin-K Oral Anticoagulants (RAF-NOACs) Study
  • 2017
  • Ingår i: Journal of the American Heart Association. - : Ovid Technologies (Wolters Kluwer Health). - 2047-9980. ; 6:12
  • Tidskriftsartikel (refereegranskat)abstract
    • Background-The optimal timing to administer non-vitamin K oral anticoagulants (NOACs) in patients with acute ischemic stroke and atrial fibrillation is unclear. This prospective observational multicenter study evaluated the rates of early recurrence and major bleeding (within 90 days) and theirtiming in patients with acute ischemic stroke and atrial fibrillation who received NOACs for secondary prevention. Methods and Results-Recurrence was defined as the composite of ischemic stroke, transient ischemic attack, and symptomatic systemic embolism, and major bleeding was defined as symptomatic cerebral and major extracranial bleeding. For the analysis, 1127 patients were eligible: 381 (33.8%) were treated with dabigatran, 366 (32.5%) with rivaroxaban, and 380 (33.7%) with apixaban. Patients who received dabigatran were younger and had lower admission National Institutes of Health Stroke Scale score and less commonly had a CHA(2)DS(2)-VASc score >4 and less reduced renal function. Thirty-two patients (2.8%) had early recurrence, and 27 (2.4%) had major bleeding. The rates of early recurrence and major bleeding were, respectively, 1.8% and 0.5% in patients receiving dabigatran, 1.6% and 2.5% in those receiving rivaroxaban, and 4.0% and 2.9% in those receiving apixaban. Patients who initiated NOACs within 2 days after acute stroke had a composite rate of recurrence and major bleeding of 12.4%; composite rates were 2.1% for those who initiated NOACs between 3 and 14 days and 9.1% for those who initiated > 14 days after acute stroke. Conclusions-In patients with acute ischemic stroke and atrial fibrillation, treatment with NOACs was associated with a combined 5% rate of ischemic embolic recurrence and severe bleeding within 90 days.
  •  
22.
  • Paciaroni, M., et al. (författare)
  • Hemorrhagic transformation in patients with acute ischemic stroke and atrial fibrillation: Time to initiation of oral anticoagulant therapy and outcomes
  • 2018
  • Ingår i: Journal of the American Heart Association. - 2047-9980. ; 7:22
  • Tidskriftsartikel (refereegranskat)abstract
    • Background—In patients with acute ischemic stroke and atrial fibrillation, early anticoagulation prevents ischemic recurrence but with the risk of hemorrhagic transformation (HT). The aims of this study were to evaluate in consecutive patients with acute stroke and atrial fibrillation (1) the incidence of early HT, (2) the time to initiation of anticoagulation in patients with HT, (3) the association of HT with ischemic recurrences, and (4) the association of HT with clinical outcome at 90 days. Methods and Results—HT was diagnosed by a second brain computed tomographic scan performed 24 to 72 hours after stroke onset. The incidence of ischemic recurrences as well as mortality or disability (modified Rankin Scale scores >2) were evaluated at 90 days. Ischemic recurrences were the composite of ischemic stroke, transient ischemic attack, or systemic embolism. Among the 2183 patients included in the study, 241 (11.0%) had HT. Patients with and without HT initiated anticoagulant therapy after a mean 23.3 and 11.6 days, respectively, from index stroke. At 90 days, 4.6% (95% confidence interval, 2.3-8.0) of the patients with HT had ischemic recurrences compared with 4.9% (95% confidence interval, 4.0-6.0) of those without HT; 53.1% of patients with HT were deceased or disabled compared with 35.8% of those without HT. On multivariable analysis, HT was associated with mortality or disability (odds ratio, 1.71; 95% confidence interval, 1.24-2.35). Conclusions—In patients with HT, anticoagulation was initiated about 12 days later than patients without HT. This delay was not associated with increased detection of ischemic recurrence. HT was associated with increased mortality or disability. © 2018 The Authors.
  •  
23.
  • Reddy, Hemanth K. N., et al. (författare)
  • Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source
  • 2017
  • Ingår i: Scientia Danica. Series H. Humanistica 4. - : Nature Publishing Group. - 1904-5506 .- 2052-4463. ; 4
  • Tidskriftsartikel (refereegranskat)abstract
    • Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65-70 nm, which is considerably smaller than the previously reported similar to 600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. The data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.
  •  
24.
  • Abdelhameed, A. H., et al. (författare)
  • First results on sub-GeV spin-dependent dark matter interactions with Li-7
  • 2019
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 79:7
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work, we want to highlight the potential of lithium as a target for spin-dependent dark matter search in cryogenic experiments, with a special focus on the low-mass region of the parameter space. We operated a prototype detector module based on a Li2MoO4 target crystal in an above-ground laboratory. Despite the high background environment, the detector sets a competitive limit on spin-dependent interactions of dark matter particles with protons and neutrons for masses between 1.5 GeV/c(2).
  •  
25.
  • Aprile, E., et al. (författare)
  • An approximate likelihood for nuclear recoil searches with XENON1T data
  • 2022
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 82:11
  • Tidskriftsartikel (refereegranskat)abstract
    • The XENON collaboration has published stringent limits on specific dark matter – nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 t-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method we present. The approximate likelihood is constructed in bins of reconstructed energy, profiled along the signal expectation in each bin. This approach can be used to compute an approximate likelihood and therefore most statistical results for any nuclear recoil spectrum. Computing approximate results with this method is approximately three orders of magnitude faster than the likelihood used in the original publications of XENON1T, where limits were set for specific families of recoil spectra. Using this same method, we include toy Monte Carlo simulation-derived binwise likelihoods for the upcoming XENONnT experiment that can similarly be used to assess the sensitivity to arbitrary nuclear recoil signatures in its eventual 20 t-year exposure.
  •  
26.
  • Aprile, E., et al. (författare)
  • Application and modeling of an online distillation method to reduce krypton and argon in XENON1T
  • 2022
  • Ingår i: Progress of Theoretical and Experimental Physics. - : Oxford University Press (OUP). - 2050-3911. ; 2022:5
  • Tidskriftsartikel (refereegranskat)abstract
    • A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of (360 +/- 60) ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fitted to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove Ar-37 after its injection for a low-energy calibration in XENON1T. This makes the usage of Ar-37 as a regular calibration source possible in the future. The online distillation can be applied to next-generation liquid xenon time projection chamber experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large-scale detectors.
  •  
27.
  • Aprile, E., et al. (författare)
  • Double-weak decays of 124Xe and 136Xe in the XENON1T and XENONnT experiments
  • 2022
  • Ingår i: Physical Review C. - 2469-9985 .- 2469-9993. ; 106:2
  • Tidskriftsartikel (refereegranskat)abstract
    • We present results on the search for two-neutrino double-electron capture (2νECEC) of 124Xe and neutrinoless double-β decay (0νββ) of 136Xe in XENON1T. We consider captures from the K shell up to the N shell in the 2νECEC signal model and measure a total half-life of T2νECEC1/2=(1.1±0.2stat±0.1sys)×1022yr with a 0.87 kg yr isotope exposure. The statistical significance of the signal is 7.0σ. We use XENON1T data with 36.16 kg yr of 136Xe exposure to search for 0νββ. We find no evidence of a signal and set a lower limit on the half-life of T0νββ1/2>1.2×1024 yr at 90%CL. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to 0νββ. Assuming a 275 kg yr 136Xe exposure, the expected sensitivity is T0νββ1/2>2.1×1025 yr at 90%CL, corresponding to an effective Majorana mass range of ⟨mββ⟩<(0.19–0.59)eV/c2.
  •  
28.
  • Aprile, E., et al. (författare)
  • Effective Field Theory and Inelastic Dark Matter Results from XENON1T
  • Annan publikation (övrigt vetenskapligt/konstnärligt)abstract
    • In this work we expand on the XENON1T nuclear recoil searches and study the individual signals of Dark Matter interactions from operators up to dimension-eight in a Chiral Effective Field Theory (ChEFT) as well as a model of inelastic Dark Matter using data from the two science runs of the detector totalling 1 tonne*year exposure. For these analyses we extended the region of interest from [4.9, 40.9]keVnr to [4.9, 54.4]keVnr to enhance our sensitivity for signals that peak at nonzero energies. We show that the data is consistent with a background only hypothesis, with small excesses in the models which peak between 20 and 50keVnr, obtaining a maximum local discovery significance of 1.7 for the VVs ChEFT model for a WIMP mass of 70GeV/c2, and 1.8 for an iDM particle of 50GeV/c2 with a mass splitting of 100keV/c2. For each model we report 90% confidence level upper limits. We also report limits on three benchmark models of WIMP interaction using ChEFT for which we investigate the effect of isospin breaking interactions, reporting up to 6 orders of magnitude weaker limits with respect to the isospin conserving case driven by cancellations in the expected rate.
  •  
29.
  • Aprile, E., et al. (författare)
  • Emission of single and few electrons in XENON1T and limits on light dark matter
  • 2022
  • Ingår i: Physical Review D. - 2470-0010 .- 2470-0029. ; 106:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates <30 events/(electron×kg×day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons.
  •  
30.
  • Aprile, E., et al. (författare)
  • Material radiopurity control in the XENONnT experiment
  • 2022
  • Ingår i: European Physical Journal C. - : Springer Science and Business Media LLC. - 1434-6044 .- 1434-6052. ; 82:7
  • Tidskriftsartikel (refereegranskat)abstract
    • The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background (∼∼17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222Rn activity concentration in XENONnT is determined to be 4.2 (+0.5−0.7) μBq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 66

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy