SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Persson Mats) "

Sökning: WFRF:(Persson Mats)

  • Resultat 11-20 av 912
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  • Brunskog, Rickard, et al. (författare)
  • First experimental evaluation of a high-resolution deep silicon photon-counting sensor
  • 2024
  • Ingår i: Journal of Medical Imaging. - : SPIE-Intl Soc Optical Eng. - 2329-4302 .- 2329-4310. ; 11:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Current photon-counting computed tomography detectors are limited to a pixel size of around 0.3 to 0.5 mm due to excessive charge sharing degrading the dose efficiency and energy resolution as the pixels become smaller. In this work, we present measurements of a prototype photon-counting detector that leverages the charge sharing to reach a theoretical sub-pixel resolution in the order of 1 μm. The goal of the study is to validate our Monte-Carlo simulation using measurements, enabling further development. Approach: We measure the channel response at the MAX IV Lab, in the DanMAX beamline, with a 35 keV photon beam, and compare the measurements with a 2D Monte Carlo simulation combined with a charge transport model. Only a few channels on the prototype are connected to keep the number of wire bonds low. Results: The measurements agree generally well with the simulations with the beam close to the electrodes but diverge as the beam is moved further away. The induced charge cloud signals also seem to increase linearly as the beam is moved away from the electrodes. Conclusions: The agreement between measurements and simulations indicates that the Monte-Carlo simulation can accurately model the channel response of the detector with the photon interactions close to the electrodes, which indicates that the unconnected electrodes introduce unwanted effects that need to be further explored. With the same Monte-Carlo simulation previously indicating a resolution of around 1 μm with similar geometry, the results are promising that an ultra-high resolution detector is not far in the future.
  •  
12.
  • Bülow-Hübe, Helena, 1964-, et al. (författare)
  • Nuläge termisk komfort : en kunskapssammanställning
  • 2022
  • Rapport (övrigt vetenskapligt/konstnärligt)abstract
    • Boverket ser ett behov av en kunskapssammanställning kring nuläget inom termisk komfort i Sverige för att ha en så bred och korrekt förståelse som möjligt för vem branschen är, vilka regler som tillämpas, var det finns kunskapscentra och vilka utvecklingsbehov som behöver stödjas för att branschen ska kunna ta större ansvar.Några faktafrågeställningar som vi författare noterat och som kan vara värda att kartlägga ytterligare:Metoder att simuleraKlimatdata för analyser och simuleringarBetydelsen av värmeöarÅtgärder för att minska värmelaster på byggnaderörbereda plats i byggnader för komfortkylaRisker med fukt och påväxt vid komfortkylaPrioriterade rum för termisk komfortUpplåtelseformers inverkan, utsatta grupper och lokala reglerVädring och fläktarPrioritera passiva åtgärderPortabel luftkylning/komfortkylaTillsyn och bygglovKrav som inte är samordnade (energi, dagsljus, buller, etc.)VarningssystemFörhoppningen är att kartläggning av termisk komfort ska bidra till kunskapsspridning om bransch, aktörer, teknik, system, konstruktion, kontroller, drift och underhåll samt forskning och utveckling.
  •  
13.
  • Chen, Han, et al. (författare)
  • A photon-counting silicon-strip detector for digital mammography with an ultrafast 0.18-mu m CMOS ASIC
  • 2014
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier. - 0168-9002 .- 1872-9576. ; 749, s. 1-6
  • Tidskriftsartikel (refereegranskat)abstract
    • We have evaluated a silicon-strip detector with a 0.18-mu m CMOS application specific integrated circuits (ASIC) containing 160 channels for use in photon-counting digital mammography. Measurements were performed at the Elettra light source using monochromatic X-ray beams with different energies and intensities. Energy resolution, Delta E/E-in, was measured to vary between 0.10 and 0.23 in the energy range of 15-40 keV. Pulse pileup has shown little effect on energy resolution.
  •  
14.
  • Chen, Han, 1986-, et al. (författare)
  • Optimization Of Beam Quality For Photon-Counting Spectral Computed Tomography In Head Imaging: Simulation Study
  • 2015
  • Ingår i: Journal of Medical Imaging. - : SPIE. - 2329-4302 .- 2329-4310. ; 2:4, s. 043504-1-043504-16
  • Tidskriftsartikel (refereegranskat)abstract
    • Head computed tomography (CT) plays an important role in the comprehensive evaluation of acutestroke. Photon-counting spectral detectors, as promising candidates for use in the next generation of x-ray CTsystems, allow for assigning more weight to low-energy x-rays that generally contain more contrast information.Most importantly, the spectral information can be utilized to decompose the original set of energy-selectiveimages into several basis function images that are inherently free of beam-hardening artifacts, a potential ad-vantage for further improving the diagnosis accuracy. We are developing a photon-counting spectral detector forCT applications. The purpose of this work is to determine the optimal beam quality for material decomposition intwo head imaging cases: nonenhanced imaging and K-edge imaging. A cylindrical brain tissue of 16-cm diam-eter, coated by a 6-mm-thick bone layer and 2-mm-thick skin layer, was used as a head phantom. The imagingtarget was a 5-mm-thick blood vessel centered in the head phantom. In K-edge imaging, two contrast agents,iodine and gadolinium, with the same concentration (5mg∕mL) were studied. Three parameters that affect beamquality were evaluated: kVp settings (50 to 130 kVp), filter materials (Z¼13to 83), and filter thicknesses [0 to 2half-value layer (HVL)]. The image qualities resulting from the varying x-ray beams were compared in terms oftwo figures of merit (FOMs): squared signal-difference-to-noise ratio normalized by brain dose (SDNR2∕BD) andthat normalized by skin dose (SDNR2∕SD). For nonenhanced imaging, the results show that the use of the 120-kVp spectrum filtered by 2 HVL copper (Z¼29) provides the best performance in both FOMs. When iodine isused in K-edge imaging, the optimal filter is 2 HVL iodine (Z¼53) and the optimal kVps are 60 kVp in terms ofSDNR2∕BD and 75 kVp in terms of SDNR2∕SD. A tradeoff of 65 kVp was proposed to lower the potential riskof skin injuries if a relatively long exposure time is necessarily performed in the iodinated imaging. In the case ofgadolinium imaging, both SD and BD can be minimized at 120 kVp filtered with 2 HVL thulium (Z¼69). Theresults also indicate that with the same concentration and their respective optimal spectrum, the values ofSDNR2∕BD and SDNR2∕SD in gadolinium imaging are, respectively, around 3 and 10 times larger thanthose in iodine imaging. However, since gadolinium is used in much lower concentrations than iodine in theclinic, iodine may be a preferable candidate for K-edge imaging.
  •  
15.
  • da Silva, Joakim, et al. (författare)
  • Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning
  • 2019
  • Ingår i: Journal of Medical Imaging. - USA : SPIE - International Society for Optical Engineering. - 2329-4302 .- 2329-4310. ; 6:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Photon-counting detectors are expected to bring a range of improvements to patient imaging with x-ray computed tomography (CT). One is higher spatial resolution. We demonstrate the resolution obtained using a commercial CT scanner where the original energy-integrating detector has been replaced by a single-slice, silicon-based, photon-counting detector. This prototype constitutes the first full-field-of-view silicon-based CT scanner capable of patient scanning. First, the pixel response function and focal spot profile are measured and, combining the two, the system modulation transfer function is calculated. Second, the prototype is used to scan a resolution phantom and a skull phantom. The resolution images are compared to images from a state-of-the-art CT scanner. The comparison shows that for the prototype 19 lp∕cm are detectable with the same clarity as 14 lp∕cm on the reference scanner at equal dose and reconstruction grid, with more line pairs visible with increasing dose and decreasing image pixel size. The high spatial resolution remains evident in the anatomy of the skull phantom and is comparable to that of other photon-counting CT prototypes present in the literature. We conclude that the deep silicon-based detector used in our study could provide improved spatial resolution in patient imaging without increasing the x-ray dose.
  •  
16.
  • Daniel, Maxime, et al. (författare)
  • Charge collection efficiency of CdTe detectors : Impact of charge collection time and polarisation
  • 2023
  • Ingår i: Medical Imaging 2023. - : SPIE-Intl Soc Optical Eng.
  • Konferensbidrag (refereegranskat)abstract
    • Cadmium telluride (CdTe) is one of the materials used in photon-counting detectors for x-ray computed tomography. One challenge with this material is that it is susceptible to polarisation due to holes being trapped in impurities in the material. This can potentially lead to the buildup of bulk charge in the semiconductor, causing decreased charge collection efficiency and degraded energy resolution. In this work, we develop a simulation model of CdTe detectors with polarisation and use it to study the effect of polarisation on the measured energy spectrum for different charge collection times. To this end, we use a theoretical model of charge buildup to find the critical charge in the detector's bulk above which the detector can be considered completely polarised. We then simulate a 320-by-270-by-1600 μm CdTe detector used in CT clinical imaging, for varying degrees of polarisation (ratio between the actual charge and the critical charge) and charge collection time. Our results show that the measured spectrum gets heavily distorted for large degrees of polarisation or for short charge collection time. We also put these results in context by discussing how they relate to the critical fluence rate and the time of flight of the charge carriers. These results can lead to improved simulation models of CdTe detectors and a better understanding the factors affecting their imaging performance.
  •  
17.
  •  
18.
  • Danielsson, Mats, Professor, et al. (författare)
  • Photon-counting x-ray detectors for CT
  • 2021
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 66:3, s. 03TR01-
  • Forskningsöversikt (refereegranskat)abstract
    • The introduction of photon-counting detectors is expected to be the next major breakthrough in clinical x-ray CT. During the last decade, there has been considerable research activity in the field of photon-counting CT, in terms of both hardware development and theoretical understanding of the factors affecting image quality. In this article, we review the recent progress in this field with the intent of highlighting the relationship between detector design considerations and the resulting image quality. We discuss detector design choices such as converter material, pixel size, and readout electronics design, and then elucidate their impact on detector performance in terms of dose efficiency, spatial resolution, and energy resolution. Furthermore, we give an overview of data processing, reconstruction methods and metrics of imaging performance; outline clinical applications; and discuss potential future developments.
  •  
19.
  •  
20.
  • Engström, Gunnar, et al. (författare)
  • The Swedish CArdioPulmonary BioImage Study : objectives and design
  • 2015
  • Ingår i: Journal of Internal Medicine. - : Wiley. - 0954-6820 .- 1365-2796. ; 278:6, s. 645-659
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiopulmonary diseases are major causes of death worldwide, but currently recommended strategies for diagnosis and prevention may be outdated because of recent changes in risk factor patterns. The Swedish CArdioPulmonarybioImage Study (SCAPIS) combines the use of new imaging technologies, advances in large-scale 'omics' and epidemiological analyses to extensively characterize a Swedish cohort of 30 000 men and women aged between 50 and 64 years. The information obtained will be used to improve risk prediction of cardiopulmonary diseases and optimize the ability to study disease mechanisms. A comprehensive pilot study in 1111 individuals, which was completed in 2012, demonstrated the feasibility and financial and ethical consequences of SCAPIS. Recruitment to the national, multicentre study has recently started.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-20 av 912
Typ av publikation
tidskriftsartikel (491)
konferensbidrag (143)
rapport (108)
doktorsavhandling (43)
bokkapitel (42)
bok (24)
visa fler...
annan publikation (24)
samlingsverk (redaktörskap) (10)
patent (9)
forskningsöversikt (6)
recension (6)
konstnärligt arbete (3)
licentiatavhandling (3)
visa färre...
Typ av innehåll
refereegranskat (565)
övrigt vetenskapligt/konstnärligt (294)
populärvet., debatt m.m. (53)
Författare/redaktör
Persson, Mats (238)
Persson, Mats, 1954 (77)
Persson, Mats, 1987- (55)
Ohlin, Mats (32)
Persson, Jonas (28)
Bornefalk, Hans (24)
visa fler...
Danielsson, Mats (23)
Johansson, Mats (21)
Persson, Helena (21)
Danielsson, Mats, Pr ... (21)
Gustafsson, Mats (20)
Persson, Kristin (19)
Persson, Ylva (19)
Tysklind, Mats (18)
Nilsson, Mats (15)
Andersson, Mats (15)
Xu, Cheng (15)
Karlsson, Staffan (14)
Dyer, M. S. (14)
Persson, Lennart (13)
Svanberg, Sune (12)
Persson, Anders (12)
Wahlgren, Mats (12)
Persson, Tomas (12)
Öberg, Lars (12)
Persson, Linda (12)
Persson, Martin (12)
Persson, Vilhelm (12)
Grönberg, Fredrik (12)
Persson, Torsten (11)
Persson, Jeanette (11)
Persson, Mats, PhD, ... (11)
Engström, Gunnar (10)
Eriksson, Mats (10)
Persson, Lars-Åke (10)
Målqvist, Mats (10)
Landin, Anne (10)
Samuelson, Lars (9)
Persson, Margaretha (9)
Wallin, Lars (9)
Agell, Jonas (9)
Pistol, Mats Erik (9)
Eriksson, Leif (9)
Nygren, Mats (9)
Käll, Per-Olov (9)
Björk, Jonas (9)
Thell, Arne (9)
Hansson, Mats (9)
Persson, Kristina (9)
Wahlberg, Lena (9)
visa färre...
Lärosäte
Lunds universitet (216)
Uppsala universitet (147)
Kungliga Tekniska Högskolan (139)
Chalmers tekniska högskola (93)
Stockholms universitet (92)
Linköpings universitet (92)
visa fler...
Umeå universitet (77)
Karolinska Institutet (71)
Göteborgs universitet (44)
Malmö universitet (36)
Sveriges Lantbruksuniversitet (31)
Örebro universitet (23)
Högskolan Dalarna (21)
Mittuniversitetet (19)
Linnéuniversitetet (12)
Karlstads universitet (12)
Luleå tekniska universitet (11)
Högskolan i Halmstad (11)
Handelshögskolan i Stockholm (9)
RISE (9)
Södertörns högskola (6)
Högskolan i Skövde (6)
Högskolan Kristianstad (5)
Jönköping University (5)
IVL Svenska Miljöinstitutet (4)
Gymnastik- och idrottshögskolan (3)
Högskolan i Borås (3)
Försvarshögskolan (3)
Nordiska Afrikainstitutet (2)
Mälardalens universitet (2)
Havs- och vattenmyndigheten (2)
Kungl. Musikhögskolan (2)
Högskolan i Gävle (1)
Naturvårdsverket (1)
Marie Cederschiöld högskola (1)
visa färre...
Språk
Engelska (710)
Svenska (196)
Odefinierat språk (5)
Tyska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (211)
Teknik (210)
Medicin och hälsovetenskap (210)
Samhällsvetenskap (169)
Humaniora (46)
Lantbruksvetenskap (28)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy