SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Petersson S) "

Sökning: WFRF:(Petersson S)

  • Resultat 41-50 av 495
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
41.
  •  
42.
  • Jhund, Pardeep S., et al. (författare)
  • Dapagliflozin across the Range of Ejection Fraction in Patients with Heart Failure : A Patient-Level, Pooled Meta-Analysis of DAPA-HF and DELIVER.
  • 2022
  • Ingår i: Nature medicine. - : Springer Science and Business Media LLC. - 1078-8956 .- 1546-170X. ; 28:9, s. 1956-1964
  • Tidskriftsartikel (refereegranskat)abstract
    • Whether the sodium-glucose cotransporter 2 inhibitor dapagliflozin reduces the risk of a range of morbidity and mortality outcomes in patients with heart failure regardless of ejection fraction is unknown. A patient-level pooled meta-analysis of two trials testing dapagliflozin in participants with heart failure and different ranges of left ventricular ejection fraction ($<$/=40% and $>$40%) was pre-specified to examine the effect of treatment on endpoints that neither trial, individually, was powered for and to test the consistency of the effect of dapagliflozin across the range of ejection fractions. The pre-specified endpoints were: death from cardiovascular causes; death from any cause; total hospital admissions for heart failure; and the composite of death from cardiovascular causes, myocardial infarction or stroke (major adverse cardiovascular events (MACEs)). A total of 11,007 participants with a mean ejection fraction of 44% (s.d. 14%) were included. Dapagliflozin reduced the risk of death from cardiovascular causes (hazard ratio (HR) 0.86, 95% confidence interval (CI) 0.76-0.97; P = 0.01), death from any cause (HR 0.90, 95% CI 0.82-0.99; P = 0.03), total hospital admissions for heart failure (rate ratio 0.71, 95% CI 0.65-0.78; P $<$ 0.001) and MACEs (HR 0.90, 95% CI 0.81-1.00; P = 0.045). There was no evidence that the effect of dapagliflozin differed by ejection fraction. In a patient- level pooled meta-analysis covering the full range of ejection fractions in patients with heart failure, dapagliflozin reduced the risk of death from cardiovascular causes and hospital admissions for heart failure (PROSPERO: CRD42022346524).
  •  
43.
  • Kuschmierz, Paul, et al. (författare)
  • European first-year university students accept evolution but lack substantial knowledge about it : A standardized European cross-country assessment
  • 2021
  • Ingår i: Evolution. - : BioMed Central (BMC). - 1936-6426 .- 1936-6434. ; 14:1, s. 1-22
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Investigations of evolution knowledge and acceptance and their relation are central to evolution education research. Ambiguous results in this field of study demonstrate a variety of measuring issues, for instance differently theorized constructs, or a lack of standardized methods, especially for cross-country comparisons. In particular, meaningful comparisons across European countries, with their varying cultural backgrounds and education systems, are rare, often include only few countries, and lack standardization. To address these deficits, we conducted a standardized European survey, on 9200 first-year university students in 26 European countries utilizing a validated, comprehensive questionnaire, the “Evolution Education Questionnaire”, to assess evolution acceptance and knowledge, as well as influencing factors on evolution acceptance. Results: We found that, despite European countries’ different cultural backgrounds and education systems, European first-year university students generally accept evolution. At the same time, they lack substantial knowledge about it, even if they are enrolled in a biology-related study program. Additionally, we developed a multilevel-model that determines religious faith as the main influencing factor in accepting evolution. According to our model, knowledge about evolution and interest in biological topics also increase acceptance of evolution, but to a much lesser extent than religious faith. The effect of age and sex, as well as the country’s affiliation, students’ denomination, and whether or not a student is enrolled in a biology-related university program, is negligible. Conclusions: Our findings indicate that, despite all their differences, most of the European education systems for upper secondary education lead to acceptance of evolution at least in university students. It appears that, at least in this sample, the differences in knowledge between countries reflect neither the extent to which school curricula cover evolutionary biology nor the percentage of biology-related students in the country samples. Future studies should investigate the role of different European school curricula, identify particularly problematic or underrepresented evolutionary concepts in biology education, and analyze the role of religious faith when teaching evolution.
  •  
44.
  • Litaudon, X., et al. (författare)
  • 14 MeV calibration of JET neutron detectors-phase 1: Calibration and characterization of the neutron source
  • 2018
  • Ingår i: Nuclear Fusion. - : IOP Publishing. - 1741-4326 .- 0029-5515. ; 58:2
  • Tidskriftsartikel (refereegranskat)abstract
    • In view of the planned DT operations at JET, a calibration of the JET neutron monitors at 14 MeV neutron energy is needed using a 14 MeV neutron generator deployed inside the vacuum vessel by the JET remote handling system. The target accuracy of this calibration is 10% as also required by ITER, where a precise neutron yield measurement is important, e.g. for tritium accountancy. To achieve this accuracy, the 14 MeV neutron generator selected as the calibration source has been fully characterised and calibrated prior to the in-vessel calibration of the JET monitors. This paper describes the measurements performed using different types of neutron detectors, spectrometers, calibrated long counters and activation foils which allowed us to obtain the neutron emission rate and the anisotropy of the neutron generator, i.e.The neutron flux and energy spectrum dependence on emission angle, and to derive the absolute emission rate in 4π sr. The use of high resolution diamond spectrometers made it possible to resolve the complex features of the neutron energy spectra resulting from the mixed D/T beam ions reacting with the D/T nuclei present in the neutron generator target. As the neutron generator is not a stable neutron source, several monitoring detectors were attached to it by means of an ad hoc mechanical structure to continuously monitor the neutron emission rate during the in-vessel calibration. These monitoring detectors, two diamond diodes and activation foils, have been calibrated in terms of neutrons/counts within ± 5% total uncertainty. A neutron source routine has been developed, able to produce the neutron spectra resulting from all possible reactions occurring with the D/T ions in the beam impinging on the Ti D/T target. The neutron energy spectra calculated by combining the source routine with a MCNP model of the neutron generator have been validated by the measurements. These numerical tools will be key in analysing the results from the in-vessel calibration and to derive the response of the JET neutron detectors to DT plasma neutrons starting from the response to the generator neutrons, and taking into account all the calibration circumstances.
  •  
45.
  •  
46.
  • Pegourie, B., et al. (författare)
  • Deuterium inventory in Tore Supra : Coupled carbon-deuterium balance
  • 2013
  • Ingår i: Journal of Nuclear Materials. - : Elsevier BV. - 0022-3115 .- 1873-4820. ; 438:Suppl., s. S120-S125
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper presents an analysis of the carbon-deuterium circulation and the resulting balance in Tore Supra over the period 2002-2007. Carbon balance combines the estimation of carbon gross erosion from spectroscopy, net erosion and deposition using confocal microscopy, lock-in thermography and SEM, and a measure of the amount of deposits collected in the vacuum chamber. Fuel retention is determined from post-mortem (PM) analyses and gas balance (GB) measurements. Special attention was paid to the deuterium outgassed during the nights and weekends of the experimental campaign (vessel under vacuum, Plasma Facing Components at 120 degrees C) and during vents (vessel at atmospheric pressure, PFCs at room temperature). It is shown that this outgassing is the main process reconciling the PM and GB estimations of fuel retention, closing the coupled carbon-deuterium balance. In particular, it explains why the deuterium concentration in deposits decreases with increasing depth.
  •  
47.
  • Sandeman, S., et al. (författare)
  • Characterising Nanoporous Carbon Adsorbents for Biological Application to Chronic Kidney Disease
  • 2012
  • Ingår i: Journal of Biomaterials and Tissue Engineering. - : American Scientific Publishers. - 2157-9083 .- 2157-9091. ; 2:1, s. 40-47
  • Tidskriftsartikel (refereegranskat)abstract
    • The study characterises a range of advanced MAST carbons derived from pyrolysed porous phenolic resins for use in biological applications, considering how the porosity of the carbons impacts both the methods used to assess potential cytotoxicity and the removal of biological molecules relevant to kidney disease. The large surface area and pore volume available for adsorption make both the microporous and the mesoporous MAST carbons suitable for creatinine removal but not for removal of the small but highly water soluble urea. However, only the highly adsorbent MAST carbons with meso- and macroporosity were able to remove the high molecular weight inflammatory cytokine IL-6. It is the adsorption of the larger biological toxins, represented by IL-6 in this study and not removed by purely microporous carbons or in current haemodialysis therapy, which could most significantly contribute to the augmentation of current haemoperfusion therapy.
  •  
48.
  • Adamson, Carly, et al. (författare)
  • Dapagliflozin for Heart Failure According to Body Mass Index : The DELIVER Trial.
  • 2022
  • Ingår i: European heart journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 43:41, s. 4406-4417
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Obesity is common and associated with unique phenotypic features in heart failure with preserved ejection fraction (HFpEF). Therefore, understanding the efficacy and safety of new therapies in HFpEF patients with obesity is important. The effects of dapagliflozin were examined according to body mass index (BMI) among patients in the Dapagliflozin Evaluation to Improve the LIVEs of Patients With PReserved Ejection Fraction Heart Failure trial. METHODS AND RESULTS: Body mass index was analysed by World Health Organization (WHO) categories and as a continuous variable using restricted cubic splines. Body mass index ranged from 15.2 to 50 kg/m2 with a mean value of 29.8 (standard deviation +/- 6.1) kg/m2. The proportions, by WHO category, were: normal weight 1343 (21.5%); overweight 2073 (33.1%); Class I obesity 1574 (25.2%); Class II obesity 798 (12.8%); and Class III obesity 415 (6.6%). Compared with placebo, dapagliflozin reduced the risk of the primary outcome to a similar extent across these categories: hazard ratio (95% confidence interval): 0.89 (0.69-1.15), 0.87 (0.70-1.08), 0.74 (0.58-0.93), 0.78 (0.57-1.08), and 0.72 (0.47-1.08), respectively (P-interaction = 0.82). The placebo-corrected change in Kansas City Cardiomyopathy Questionnaire total symptom score with dapagliflozin at 8 months was: 0.9 (-1.1, 2.8), 2.5 (0.8, 4.1), 1.9 (-0.1, 3.8), 2.7 (-0.5, 5.8), and 8.6 (4.0, 13.2) points, respectively (P-interaction = 0.03). The placebo-corrected change in weight at 12 months was: -0.88 (-1.28, -0.47), -0.65 (-1.04, -0.26), -1.42 (-1.89, -0.94), -1.17 (-1.94, -0.40), and -2.50 (-4.4, -0.64) kg (P-interaction = 0.002). CONCLUSIONS: Obesity is common in patients with HFpEF and is associated with higher rates of heart failure hospitalization and worse health status. Treatment with dapagliflozin improves cardiovascular outcomes across the spectrum of BMI, leads to greater symptom improvement in patients with obesity, compared with those without, and has the additional benefit of causing modest weight loss.
  •  
49.
  •  
50.
  • Batistoni, P., et al. (författare)
  • 14 MeV calibration of JET neutron detectors-phase 2 : in-vessel calibration
  • 2018
  • Ingår i: Nuclear Fusion. - : IOP PUBLISHING LTD. - 0029-5515 .- 1741-4326. ; 58:10
  • Tidskriftsartikel (refereegranskat)abstract
    • A new DT campaign (DTE2) is planned at JET in 2020 to minimize the risks of ITER operations. In view of DT operations, a calibration of the JET neutron monitors at 14 MeV neutron energy has been performed using a well calibrated 14 MeV neutron generator (NG) deployed, together with its power supply and control unit, inside the vacuum vessel by the JET remote handling system. The NG was equipped with two calibrated diamond detectors, which continuously monitored its neutron emission rate during the calibration, and activation foils which provided the time integrated yield. Cables embedded in the remote handling boom were used to power the neutron generator, the active detectors and pre-amplifier, and to transport the detectors' signal. The monitoring activation foils were retrieved at the end of each day for decay gamma-ray counting, and replaced by fresh ones. About 76 hours of irradiation, in 9 days, were needed with the neutron generator in 73 different poloidal and toroidal positions in order to calibrate the two neutron yield measuring systems available at JET, the U-235 fission chambers (KN1) and the inner activation system (KN2). The NG neutron emission rates provided by the monitoring detectors were in agreement within 3%. Neutronics calculations have been performed using MCNP code and a detailed model of JET to derive the response of the JET neutron detectors to DT plasma neutrons starting from the response to the NG neutrons, and taking into account the anisotropy of the neutron generator and all the calibration circumstances. These calculations have made use of a very detailed and validated geometrical description of the neutron generator and of the modified. MNCP neutron source subroutine producing neutron energy-angle distribution for the neutrons emitted by the NG. The KN1 calibration factor for a DT plasma has been determined with +/- 4.2%' experimental uncertainty. Corrections due to NG and remote handling effects and the plasma volume effect have been calculated by simulation modelling. The related additional uncertainties are difficult to estimate, however the results of the previous calibration in 2013 have demonstrated that such uncertainties due to modelling are globally <= +/- 3%. It has been found that the difference between KN1 response to DD neutrons and that to DT neutrons is within the uncertainties in the derived responses. KN2 has been calibrated using the Nb-93(n,2n)Nb-92m and Al-27(n,a)Na-24 activation reactions (energy thresholds 10 MeV and 5 MeV respectively). The total uncertainty on the calibration factors is +/- 6% for Nb-93(n,2n)Nb-92m and +/- 8% Al-27(n,a)Na-24 (1 sigma). The calibration factors of the two independent systems KN1 and KN2 will be validated during DT operations. The experience gained and the lessons learnt are presented and discussed in particular with regard to the 14 MeV neutron calibrations in ITER.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 41-50 av 495
Typ av publikation
tidskriftsartikel (402)
konferensbidrag (61)
forskningsöversikt (14)
bokkapitel (7)
samlingsverk (redaktörskap) (5)
rapport (2)
visa fler...
annan publikation (2)
konstnärligt arbete (1)
recension (1)
visa färre...
Typ av innehåll
refereegranskat (432)
övrigt vetenskapligt/konstnärligt (62)
Författare/redaktör
Petersson, Per (113)
Rubel, Marek (105)
Zychor, I (82)
Brezinsek, S (71)
Weckmann, Armin (71)
Ström, Petter (70)
visa fler...
Frassinetti, Lorenzo (68)
Conroy, Sean (67)
Bykov, Igor (66)
Eriksson, Jacob, Dr, ... (66)
Bergsåker, Henric (64)
Hellsten, Torbjörn (63)
Cecconello, Marco (62)
Rachlew, Elisabeth, ... (61)
Menmuir, Sheena (60)
Hjalmarsson, Anders (60)
Andersson Sundén, Er ... (59)
Ericsson, Göran (59)
Possnert, Göran, 195 ... (58)
Weiszflog, Matthias (58)
Sjöstrand, Henrik, 1 ... (57)
Likonen, J (56)
Hellesen, Carl, 1980 ... (55)
Binda, Federico, 198 ... (53)
Garcia-Carrasco, Alv ... (50)
Wauters, T (49)
Skiba, Mateusz, 1985 ... (49)
Tholerus, Emmi (48)
Stefanikova, Estera (48)
Johnson, Thomas (46)
Crombe, K (45)
Dzysiuk, Nataliia (45)
Coad, J. P. (45)
Mayer, M. (44)
Zoletnik, S (44)
Koivuranta, S (43)
Nocente, M (43)
Petersson, P (43)
Alves, E (42)
Huber, A (41)
Tardocchi, M (41)
Krieger, K. (40)
Heinola, K (40)
Kirschner, A (40)
Lyssoivan, A (39)
Salewski, M (39)
Ratynskaia, Svetlana (39)
Giacomelli, L (38)
Rasmussen, J. (38)
Tolias, Panagiotis (38)
visa färre...
Lärosäte
Uppsala universitet (165)
Karolinska Institutet (159)
Kungliga Tekniska Högskolan (150)
Lunds universitet (71)
Chalmers tekniska högskola (41)
Linköpings universitet (34)
visa fler...
Göteborgs universitet (33)
Umeå universitet (17)
Mittuniversitetet (12)
Örebro universitet (11)
Linnéuniversitetet (10)
Stockholms universitet (7)
Malmö universitet (7)
Naturhistoriska riksmuseet (6)
RISE (4)
Sveriges Lantbruksuniversitet (3)
Luleå tekniska universitet (1)
Högskolan i Halmstad (1)
Mälardalens universitet (1)
Jönköping University (1)
Högskolan i Borås (1)
Karlstads universitet (1)
Högskolan Dalarna (1)
visa färre...
Språk
Engelska (483)
Svenska (9)
Odefinierat språk (2)
Portugisiska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (185)
Medicin och hälsovetenskap (98)
Teknik (49)
Samhällsvetenskap (16)
Lantbruksvetenskap (1)
Humaniora (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy