SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sörensen Jens) "

Sökning: WFRF:(Sörensen Jens)

  • Resultat 21-30 av 422
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  • Alzuhairi, Karam Sadoon, et al. (författare)
  • Sub-acute cardiac magnetic resonance to predict irreversible reduction in left ventricular ejection fraction after ST-segment elevation myocardial infarction : A DANAMI-3 sub-study
  • 2020
  • Ingår i: International Journal of Cardiology. - : Elsevier BV. - 0167-5273. ; 301, s. 215-219
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims: To predict irreversible reduction in left ventricular ejection fraction (LVEF) during admission for ST-segment elevation myocardial infarction (STEMI) using cardiac magnetic resonance (CMR) in addition to classical clinical parameters. Irreversible reduction in LVEF is an important prognostic factor after STEMI which necessitates medical therapy and implantation of prophylactic implantable cardioverter defibrillator (ICD). Methods and results: A post-hoc analysis of DANAMI-3 trial program (Third DANish Study of Optimal Acute Treatment of Patients With ST-elevation Myocardial Infarction) which recruited 649 patients who had CMR performed during index hospitalization and after 3 months. Patients were divided into two groups according to CMR-LVEF at 3 months: Group 1 with LVEF≤35% and Group 2 with LVEF>35%. Group 1 included 15 patients (2.3%) while Group 2 included 634 patients (97.7%). A multivariate analysis showed that: Killip class >1 (OR 7.39; CI:1.47–36.21, P = 0.01), symptom onset-to-wire ≥6 h (OR 7.19; CI 1.07–50.91, P = 0.04), LVEF≤35% using index echocardiography (OR 7.11; CI: 1.27–47.43, P = 0.03), and infarct size ≥40% of LV on index CMR (OR 42.62; CI:7.83–328.29, P < 0.001) independently correlated with a final LVEF≤35%. Clinical models consisted of these parameters could identify 7 out of 15 patients in Group 1 with 100% positive predictive value. Conclusion: Together with other clinical measurements, the assessment of infarct size using late Gadolinium enhancement by CMR during hospitalization is a strong predictor of irreversible reduction in CMR_LVEF ≤35. That could potentially, after validation with future research, aids the selection and treatment of high-risk patients after STEMI, including implantation of prophylactic ICD during index hospitalization.
  •  
22.
  • Andersen, S.J., et al. (författare)
  • Comparison of Engineering Wake Models with CFD Simulations
  • 2014
  • Ingår i: Journal of Physics, Conference Series. - : IOP Publishing. - 1742-6588 .- 1742-6596. ; 524, s. 012161-
  • Tidskriftsartikel (refereegranskat)abstract
    • The engineering wake models by Jensen [1] and Frandsen et al. [2] are assessed for different scenarios simulated using Large Eddy Simulation and the Actuator Line method implemented in the Navier-Stokes equations. The scenarios include the far wake behind a single wind turbine, a long row of turbines in an atmospheric boundary layer, idealised cases of an infinitely long row of wind turbines and infinite wind farms with three different spacings. Both models include a wake expansion factor, which is calibrated to fit the simulated wake velocities. The analysis highlights physical deficiencies in the ability of the models to universally predict the wake velocities, as the expansion factor can be fitted for a given case, but with not apparent transition between the cases. 1.
  •  
23.
  • Andersen, S. J., et al. (författare)
  • Quantifying variability of Large Eddy Simulations of very large wind farms
  • 2015
  • Ingår i: Wake Conference 2015. - : IOP Publishing. ; , s. 012027-
  • Konferensbidrag (refereegranskat)abstract
    • Large Eddy Simulations are inherently dynamic as the largest scales are resolved and the smallest scales are modeled temporally. This raises challenges for simulations including very large scales such as atmospheric flows, which require very long simulation times. Simple averages fail at capturing these dynamics and potentially yield misleading interpretations concerning the capabilities of different models when tested in blind tests or in benchmarking exercises such as Wakebench, where results from different flow models are compared. This article will present results from very large wind farm simulations using Actuator Disc (AD) and Line (AL) models for two different turbine spacings with turbulent inflow. The results of each numerical flow model include a certain variability, and it will be examined if different models result in comparable probability distributions.
  •  
24.
  •  
25.
  • Anrup, Roland, et al. (författare)
  • Centrala universitetsvärden hotas av bolagiseringsidén
  • 2013
  • Ingår i: Dagens nyheter. - 1101-2447.
  • Tidskriftsartikel (populärvet., debatt m.m.)abstract
    • Högskolestiftelser. Förslaget att driva svenska universitet i stiftelseform ­öppnar för bolagisering. Men det är ingen riktig utredning, utan en politisk pamflett utan ­eftertanke. Privatisering av universitet hotar både oberoendet, forskningskvaliteten och samhällsnyttan, skriver 36 forskare vid svenska högskolor och universitet.
  •  
26.
  • Antoni, Gunnar, et al. (författare)
  • In Vivo Visualization of Amyloid Deposits in the Heart with C-11-PIB and PET
  • 2013
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 54:2, s. 213-220
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiac amyloidosis is a differential diagnosis in heart failure and is associated with high mortality. There is currently no noninvasive imaging test available for specific diagnosis. N-[methyl-C-11]2-(4'-methylamino-phenyl)-6-hydroxybenzothiazole (C-11-PIB) PET is used in the evaluation of brain amyloidosis. We evaluated the potential use of C-11-PIB PET in systemic amyloidosis affecting the heart. Methods: Patients (n = 10) diagnosed with systemic amyloidosis-including heart involvement of either monoclonal immunoglobulin light-chain (AL) or transthyretin (ATTR) type- and healthy volunteers (n = 5) were investigated with PET/CT using C-11-PIB to study cardiac amyloid deposits and with C-11-acetate to measure myocardial blood flow to study the impact of global and regional perfusion on PIB retention. Results: Myocardial C-11-PIB uptake was visually evident in all patients 15-25 min after injection and was not seen in any volunteer. A significant difference in C-11-PIB retention in the heart between patients and healthy controls was found. The data indicate that myocardial amyloid deposits in patients diagnosed with systemic amyloidosis could be visualized with C-11-PIB. No correlation between C-11-PIB retention index and myocardial blood flow as measured with C-11-acetate was found on the global level, whereas a positive correlation on the segmental level was seen in a single patient. Conclusion: C-11-PIB and PET could be a method to study systemic amyloidosis of type AL and ATTR affecting the heart and should be investigated further both as a diagnostic tool and as a noninvasive method for treatment follow-up.
  •  
27.
  • Antoni, Gunnar, et al. (författare)
  • In Vivo Visualization and Quantification of Neutrophil Elastase in Lungs of COVID-19 Patients : A First-in-Humans PET Study with 11C-NES
  • 2023
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 64:1, s. 145-148
  • Tidskriftsartikel (refereegranskat)abstract
    • COVID-19 can cause life-threatening lung-inflammation that is suggested to be mediated by neutrophils, whose effector mechanisms in COVID-19 is inexplicit. The aim of the present work is to evaluate a novel PET tracer for neutrophil elastase in COVID-19 patients and healthy controls.METHODS: In this open-label, First-In-Man study, four patients with hypoxia due to COVID-19 and two healthy controls were investigated with positron emission tomography (PET) using the new selective and specific neutrophil elastase PET-tracer [11C]GW457427 and [15O]water for the visualization and quantification of NE and perfusion in the lungs, respectively.RESULTS: [11C]GW457427 accumulated selectively in lung areas with ground-glass opacities on computed tomography characteristic of COVID-19 suggesting high levels on NE in these areas. In the same areas perfusion was severely reduced in comparison to healthy lung tissue as measured with [15O]water.CONCLUSION: The data suggests that NE may be responsible for the severe lung inflammation in COVID-19 patients and that inhibition of NE could potentially reduce the acute inflammatory process and improve the condition.
  •  
28.
  • Antoni, Gunnar, et al. (författare)
  • Molecular Imaging of Transporters with Positron Emission Tomography
  • 2009
  • Ingår i: Transporters as Targets for Drugs. - Berlin : Springer. - 3540879110 - 9783540879121 - 9783540879114 ; , s. 155-186
  • Bokkapitel (refereegranskat)abstract
    • Positron emission tomography (PET) visualization of brain components in vivo is a rapidly growing field. Molecular imaging with PET is also increasingly used in drug development, especially for the determination of drug receptor interaction for CNS-active drugs. This gives the opportunity to relate clinical efficacy to per cent receptor occupancy of a drug on a certain targeted receptor and to relate drug pharmacokinetics in plasma to interaction with target protein. In the present review we will focus on the study of transporters, such as the monoamine transporters, the P-glycoprotein (Pgp) transporter, the vesicular monoamine transporter type 2, and the glucose transporter using PET radioligands. Neurotransmitter transporters are presynaptically located and in vivo imaging using PET can therefore be used for the determination of the density of afferent neurons. Several promising PET ligands for the noradrenaline transporter (NET) have been labeled and evaluated in vivo including in man, but a really useful PET ligand for NET still remains to be identified. The most promising tracer to date is (S,S)-[18F]FMeNER-D2. The in vivo visualization of the dopamine transporter (DAT) may give clues in the evaluation of conditions related to dopamine, such as Parkinson's disease and drug abuse. The first PET radioligands based on cocaine were not selective, but more recently several selective tracers such as [11C]PE2I have been characterized and shown to be suitable as PET radioligands. Although there are a large number of serotonin transporter inhibitors used today as SSRIs, it was not until very recently, when [11C]McN5652 was synthesized, that this transporter was studied using PET. New candidates as PET radioligands for the SERT have subsequently been developed and [11C]DASB and [11C]MADAM and their analogues are today the most promising ligands. The existing radioligands for Pgp transporters seem to be suitable tools for the study of both peripheral and central drug–Pgp interactions, although [11C]verapamil and [18F]fluoropaclitaxel are probably restricted to use in studies of the blood–brain barrier. The vesicular monoamine transporter 2 (VMAT2) is another interesting target for diagnostic imaging and [11C]DTBZ is a promising tracer. The noninvasive imaging of transporter density as a function of disease progression or availability following interaction with blocking drugs is highlighted, including the impact on both development of new therapies and the process of developing new drugs. Although CNS-related work focusing on psychiatric disorders is the main focus of this review, other applications of PET ligands, such as diagnosis of cancer, diabetes research, and drug interactions with efflux systems, are also discussed. The use of PET especially in terms of tracer development is briefly described. Finally, it can be concluded that there is an urgent need for new, selective radioligands for the study of the transporter systems in the human brain using PET.
  •  
29.
  • Appel, Lieuwe, et al. (författare)
  • Use of C-11-PE2I PET in Differential Diagnosis of Parkinsonian Disorders
  • 2015
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 56:2, s. 234-242
  • Tidskriftsartikel (refereegranskat)abstract
    • In idiopathic Parkinson disease and atypical parkinsonian disorders, central dopaminergic and overall brain functional activity are altered to different degrees, causing difficulties in achieving an unambiguous clinical diagnosis. A dual examination using I-123-FP-CIT (I-123-N-omega-fluoropropyl- 2 beta-carbomethoxy-3 beta-(4-iodophenyl) nortropane, or I-123-ioflupane) SPECT and F-18-FDG PET provides complementary information on dopamine transporter (DAT) availability and overall brain functional activity, respectively. Parametric images based on a single, dynamic C-11-PE2I (N-(3-iodoprop-2E-enyl)-2 beta-carbomethoxy-3 beta-(4-methyl-phenyl) nortropane) scan potentially supply both DAT availability (nondisplaceable binding potential [BPND]) and relative cerebral blood flow (relative delivery [R-1]) at voxel level. This study aimed to evaluate the validity of C-11-PE2I PET against the dual-modality approach using I-123-FP-CIT SPECT and F-18-FDG PET.Methods: Sixteen patients with parkinsonian disorders had a dual examination with F-18-FDG PET and I-123-FP-CIT SPECT following clinical routines and additionally an experimental C-11-PE2I PET scan. Parametric BPND and R-1 images were generated using receptor parametric mapping with the cerebellum as a reference. T1-weighted MR imaging was used for automated definition of volumes of interest (VOI). The DAT VOIs included the basal ganglia, whereas the overall brain functional activity was examined using VOIs across the brain. BPND and R-1 values were compared with normalized I-123-FP-CIT and F-18-FDG uptake values, respectively, using Pearson correlations and regression analyses. In addition, 2 masked interpreters evaluated the images visually, in both the routine and the experimental datasets, for comparison of patient diagnoses.Results: Parametric C-11-PE2I BPND and R-1 images showed high consistency with I-123-FP-CIT SPECT and F-18-FDG PET images. Correlations between C-11-PE2I BPND and I-123-FP-CIT uptake ratios were 0.97 and 0.76 in the putamen and caudate nucleus, respectively. Regional C-11-PE2I R-1 values were moderately to highly correlated with normalized F-18-FDG values (range, 0.61-0.94). Visual assessment of DAT availability showed a high consistency between C-11-PE2I BPND and I-123-FP-CIT images, whereas the consistency was somewhat lower for appraisal of overall brain functional activity using I-123-FP-CIT and F-18-FDG images. Substantial differences were found between clinical diagnosis and both neuro-imaging diagnoses.Conclusion: A single, dynamic C-11-PE2I PET investigation is a powerful alternative to a dual examination with I-123-FP-CIT SPECT and F-18-FDG PET for differential diagnosis of parkinsonian disorders. A large-scale patient study is, however, needed to further investigate distinct pathologic patterns in overall brain functional activity for various parkinsonian disorders.
  •  
30.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-30 av 422
Typ av publikation
tidskriftsartikel (329)
doktorsavhandling (20)
annan publikation (18)
bokkapitel (17)
konferensbidrag (14)
rapport (8)
visa fler...
forskningsöversikt (6)
bok (4)
samlingsverk (redaktörskap) (3)
recension (3)
visa färre...
Typ av innehåll
refereegranskat (246)
övrigt vetenskapligt/konstnärligt (133)
populärvet., debatt m.m. (43)
Författare/redaktör
Sörensen, Jens (314)
Lubberink, Mark (81)
Velikyan, Irina (34)
Tolmachev, Vladimir (33)
Kero, Tanja (33)
Antoni, Gunnar (32)
visa fler...
Olsson, Erik J (32)
Zetterholm, Magnus (26)
Långström, Bengt (19)
Lindman, Henrik (18)
Sandström, Mattias (16)
Johansson, Silvia (16)
Feldwisch, Joachim (14)
Eriksson, Barbro (14)
Ivanell, Stefan (14)
Lindström, Elin (13)
Jonasson, My (12)
Ahlström, Håkan (11)
Orlova, Anna (11)
Sundin, Anders (11)
Appel, Lieuwe (10)
Nilsson, Olle (10)
Danfors, Torsten (10)
Orlova, Anna, 1960- (9)
Wassberg, Cecilia (9)
Velikyan, Irina, 196 ... (9)
Stilhoff Sörensen, J ... (9)
Hedegaard Sørensen, ... (9)
Estrada, Sergio (9)
Wennborg, Anders (8)
Eriksson, Olof (8)
Hansen, Torben (8)
Alhuseinalkhudhur, A ... (8)
Hedenstierna, Göran (8)
Mikkelsen, Robert (8)
Breton, Simon-Philip ... (8)
Carlsson, Jörgen (8)
Nilsson, Karl (8)
Madison, Guy (7)
Wanhainen, Anders (7)
Chernov, Vladimir (7)
Larhed, Mats (7)
Wikström, Gerhard (7)
Rosengren, Sara (7)
Nyholm, Dag (7)
Ståhle, Elisabeth (7)
Frejd, Fredrik Y. (7)
Varasteh, Zohreh (7)
Lindeberg, Gunnar (7)
Gudmundsson, Henrik (7)
visa färre...
Lärosäte
Uppsala universitet (263)
Göteborgs universitet (84)
Lunds universitet (61)
Karolinska Institutet (24)
Umeå universitet (18)
VTI - Statens väg- och transportforskningsinstitut (12)
visa fler...
Stockholms universitet (11)
Kungliga Tekniska Högskolan (10)
Örebro universitet (4)
Chalmers tekniska högskola (4)
Linköpings universitet (2)
Linnéuniversitetet (2)
Luleå tekniska universitet (1)
Malmö universitet (1)
Södertörns högskola (1)
visa färre...
Språk
Engelska (352)
Svenska (66)
Odefinierat språk (2)
Danska (1)
Norska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (203)
Samhällsvetenskap (103)
Humaniora (40)
Teknik (26)
Naturvetenskap (24)
Lantbruksvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy