SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sinnaeve Peter) "

Sökning: WFRF:(Sinnaeve Peter)

  • Resultat 21-28 av 28
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
21.
  •  
22.
  •  
23.
  •  
24.
  • Tricoci, Pierluigi, et al. (författare)
  • Thrombin-receptor antagonist vorapaxar in acute coronary syndromes
  • 2012
  • Ingår i: New England Journal of Medicine. - 0028-4793 .- 1533-4406. ; 366:1, s. 20-33
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Vorapaxar is a new oral protease-activated-receptor 1 (PAR-1) antagonist that inhibits thrombin-induced platelet activation.METHODS:In this multinational, double-blind, randomized trial, we compared vorapaxar with placebo in 12,944 patients who had acute coronary syndromes without ST-segment elevation. The primary end point was a composite of death from cardiovascular causes, myocardial infarction, stroke, recurrent ischemia with rehospitalization, or urgent coronary revascularization.RESULTS:Follow-up in the trial was terminated early after a safety review. After a median follow-up of 502 days (interquartile range, 349 to 667), the primary end point occurred in 1031 of 6473 patients receiving vorapaxar versus 1102 of 6471 patients receiving placebo (Kaplan-Meier 2-year rate, 18.5% vs. 19.9%; hazard ratio, 0.92; 95% confidence interval [CI], 0.85 to 1.01; P=0.07). A composite of death from cardiovascular causes, myocardial infarction, or stroke occurred in 822 patients in the vorapaxar group versus 910 in the placebo group (14.7% and 16.4%, respectively; hazard ratio, 0.89; 95% CI, 0.81 to 0.98; P=0.02). Rates of moderate and severe bleeding were 7.2% in the vorapaxar group and 5.2% in the placebo group (hazard ratio, 1.35; 95% CI, 1.16 to 1.58; P<0.001). Intracranial hemorrhage rates were 1.1% and 0.2%, respectively (hazard ratio, 3.39; 95% CI, 1.78 to 6.45; P<0.001). Rates of nonhemorrhagic adverse events were similar in the two groups.CONCLUSIONS:In patients with acute coronary syndromes, the addition of vorapaxar to standard therapy did not significantly reduce the primary composite end point but significantly increased the risk of major bleeding, including intracranial hemorrhage. (Funded by Merck; TRACER ClinicalTrials.gov number, NCT00527943.).
  •  
25.
  • Ughi, Giovanni J., et al. (författare)
  • Automatic three-dimensional registration of intravascular optical coherence tomography images
  • 2012
  • Ingår i: Journal of Biomedical Optics. - 1083-3668 .- 1560-2281. ; 17:2, s. 026005-
  • Tidskriftsartikel (refereegranskat)abstract
    • Intravascular optical coherence tomography (IV-OCT) is a catheter-based high-resolution imaging technique able to visualize the inner wall of the coronary arteries and implanted devices in vivo with an axial resolution below 20 mu m. IV-OCT is being used in several clinical trials aiming to quantify the vessel response to stent implantation over time. However, stent analysis is currently performed manually and corresponding images taken at different time points are matched through a very labor-intensive and subjective procedure. We present an automated method for the spatial registration of IV-OCT datasets. Stent struts are segmented through consecutive images and three-dimensional models of the stents are created for both datasets to be registered. The two models are initially roughly registered through an automatic initialization procedure and an iterative closest point algorithm is subsequently applied for a more precise registration. To correct for nonuniform rotational distortions (NURDs) and other potential acquisition artifacts, the registration is consecutively refined on a local level. The algorithm was first validated by using an in vitro experimental setup based on a polyvinyl-alcohol gel tubular phantom. Subsequently, an in vivo validation was obtained by exploiting stable vessel landmarks. The mean registration error in vitro was quantified to be 0.14 mm in the longitudinal axis and 7.3-deg mean rotation error. In vivo validation resulted in 0.23 mm in the longitudinal axis and 10.1-deg rotation error. These results indicate that the proposed methodology can be used for automatic registration of in vivo IV-OCT datasets. Such a tool will be indispensable for larger studies on vessel healing pathophysiology and reaction to stent implantation. As such, it will be valuable in testing the performance of new generations of intracoronary devices and new therapeutic drugs.
  •  
26.
  •  
27.
  • Whellan, David J., et al. (författare)
  • Vorapaxar in Acute Coronary Syndrome Patients Undergoing Coronary Artery Bypass Graft Surgery
  • 2014
  • Ingår i: Journal of the American College of Cardiology. - : Elsevier BV. - 0735-1097 .- 1558-3597. ; 63:11, s. 1048-1057
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives This study evaluated effects of protease-activated receptor-1 antagonist vorapaxar (Merck, Whitehouse Station, New Jersey) versus placebo among the TRACER (Thrombin Receptor Antagonist for Clinical Event Reduction in Acute Coronary Syndrome) study patients with non-ST-segment elevation acute coronary syndromes undergoing coronary artery bypass grafting (CABG). Background Platelet activation may play a key role in graft occlusion, and antiplatelet therapies may reduce ischemic events, but perioperative bleeding risk remains a major concern. Although the TRACER study did not meet the primary quintuple composite outcome in the overall population with increased bleeding, an efficacy signal with vorapaxar was noted on major ischemic outcomes, and preliminary data suggest an acceptable surgical bleeding profile. We aimed to assess efficacy and safety of vorapaxar among CABG patients. Methods Associations between treatment and ischemic and bleeding outcomes were assessed using time-to-event analysis. Hazard ratios (HRs) and 95% confidence intervals (CIs) were calculated using the Cox hazards model. Event rates were estimated using the Kaplan-Meier method. Results Among 12,944 patients, 1,312 (10.1%) underwent CABG during index hospitalization, with 78% on the study drug at the time of surgery. Compared with placebo CABG patients, vorapaxar-treated patients had a 45% lower rate of the primary endpoint (i.e., a composite of death, myocardial infarction, stroke, recurrent ischemia with rehospitalization, or urgent coronary revascularizationduring index hospitalization) (HR: 0.55; 95% CI: 0.36 to 0.83; p = 0.005), with a significant interaction (p = 0.012). The CABG-related Thrombolysis In Myocardial Infarction major bleeding was numerically higher with vorapaxar, but not significantly different between vorapaxar and placebo (9.7% vs. 7.3%; HR: 1.36; 95% CI: 0.92 to 2.02; p = 0.12), with no excess in fatal bleeding (0% vs. 0.3%) or need for reoperation (4.7% vs. 4.6%). Conclusions In non-ST-segment elevation acute coronary syndrome patients undergoing CABG, vorapaxar was associated with a significant reduction in ischemic events and no significant increase in major CABG-related bleeding. These data show promise for protease-activated receptor 1 antagonism in patients undergoing CABG and warrant confirmatory evidence in randomized trials. (Trial to Assess the Effects of SCH 530348 in Preventing Heart Attack and Stroke in Patients With Acute Coronary Syndrome [TRA.CER] [Study P04736AM3]; NCT00527943) (C) 2014 by the American College of Cardiology Foundation
  •  
28.
  • 2017
  • swepub:Mat__t
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 21-28 av 28

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy