SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Tajima K) "

Sökning: WFRF:(Tajima K)

  • Resultat 141-150 av 151
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
141.
  • Kanai, Y., et al. (författare)
  • Beam test of a prototype phoswich detector assembly for the PoGOLite astronomical soft gamma-ray polarimeter
  • 2007
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 570:1, s. 61-71
  • Tidskriftsartikel (refereegranskat)abstract
    • We report about the beam test on a prototype of the balloon-based astronomical soft gamma-ray polarimeter, PoGOLite (Polarized Gamma-ray Observer-Light Version) conducted at KEK Photon Factory, a synchrotron radiation facility in Japan. The synchrotron beam was set at 30, 50, and 70 keV and its polarization was monitored by a calibrated polarimeter. The goal of the experiment was to validate the flight design of the polarimeter. PoGOLite is designed to measure polarization by detecting a Compton scattering and the subsequent photo-absorption in an array of 217 well-type phoswich detector cells (PDCs). The test setup included a first flight model PDC and a front-end electronics to select and reconstruct valid Compton scattering events. The experiment has verified that the flight PDC can detect recoil electrons and select valid Compton scattering events down to 30 keV from background. The measure azimuthal modulations (34.4%, 35.8% and 37.2% at 30, 50, and 70 keV, respectively) agreed within 10% (relative) with the predictions by Geant4 implemented with dependence on the initial and final photon polarizations.
  •  
142.
  • Kiss, Mózsi, et al. (författare)
  • The PoGOLite balloon-borne soft gamma-ray polarimeter
  • 2008
  • Ingår i: COOL DISCS, HOT FLOWS. - : AIP. ; , s. 225-232
  • Konferensbidrag (refereegranskat)abstract
    • Linearly polarized radiation in the hard X-ray/soft gamma-ray band is expected from a large variety of astronomical sources. We discuss the importance of polarimetric studies for several classes of sources - pulsars, accreting black holes. magnetic neutron stars and jets from active galaxies - and then describe PoGOLite, a balloon-borne instrument which is currently under construction and will be able to measure the polarization of electromagnetic radiation from such extra-solar objects in the energy range 25-80 keV.
  •  
143.
  • Kurita, K., et al. (författare)
  • Recent Development Status of PoGOLite
  • 2009
  • Ingår i: Astrophysics with All-Sky X-Ray Observations. ; , s. 386-
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
  •  
144.
  •  
145.
  • Mizuno, T., et al. (författare)
  • A Monte Carlo method for calculating the energy response of plastic scintillators to polarized photons below 100 keV
  • 2009
  • Ingår i: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 600:3, s. 609-617
  • Tidskriftsartikel (refereegranskat)abstract
    • The energy response of plastic scintillators (Eljen Technology EJ-204) to polarized soft gamma-ray photons below 100 keV has been studied, primarily for the balloon-borne polarimeter, PoGOLite. The response calculation includes quenching effects due to low-energy recoil electrons and the position dependence of the light collection efficiency in a 20 cm long scintillator rod. The broadening of the pulse-height spectrum, presumably caused by light transportation processes inside the scintillator, as well as the generation and multiplication of photoelectrons in the photomultiplier tube, were studied experimentally and have also been taken into account. A Monte Carlo simulation based on the Geant4 toolkit was used to model photon interactions in the scintillators. When using the polarized Compton/Rayleigh scattering processes previously corrected by the authors, scintillator spectra and angular distributions of scattered polarized photons could clearly be reproduced, in agreement with the results obtained at a synchrotron beam test conducted at the KEK Photon Factory. Our simulation successfully reproduces the modulation factor, defined as the ratio of the amplitude to the mean of the distribution of the azimuthal scattering angles, within similar to 5% (relative). Although primarily developed for the PoGOLite mission, the method presented here is also relevant for other missions aiming to measure polarization from astronomical objects using plastic scintillator scatterers. 
  •  
146.
  • Mochizuki, S., et al. (författare)
  • JIKEI HEART Study--a morbi-mortality and remodeling study with valsartan in Japanese patients with hypertension and cardiovascular disease
  • 2004
  • Ingår i: Cardiovasc Drugs Ther. - 0920-3206. ; 18:4, s. 305-9
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Several recent clinical trials have demonstrated that angiotensin II receptor blockers (ARBs) have cardiovascular as well as renal protective effects. Asian patients including Japanese were under-represented in these trials, however, and no large-scale clinical trials of ARBs have yet been performed in Japan. It is therefore important to verify that the results of these studies are also valid for Japanese patients. The JIKEI HEART Study has been designed to investigate whether concomitant treatment with valsartan, an angiotensin II receptor blocker, in addition to conventional treatment, will improve the prognosis of Japanese patients with cardiovascular diseases (hypertension, ischemic heart disease, congestive heart failure). METHOD AND EVALUATION OF RESULTS: Around 3,000 patients with hypertension, ischemic heart disease and/or congestive heart failure will be randomized to receive either additional treatment with valsartan (80 mg/day) or conventional therapy. The follow-up period will be three years. The primary endpoint will be the onset of any cardiovascular event. Secondary endpoints will include death from any cause, changes in left ventricular size and function, renal function, changes in neuro-hormonal levels and quality-of-life assessments. Sub-studies will explore the effect in patients with diabetes mellitus, hyperlipidemia and the effects of combination of drugs. CONCLUSION: Improved prognosis would confirm the role of angiotensin II receptor blockers in the treatment of the cardiovascular disease in Japanese patients.
  •  
147.
  •  
148.
  • Takahashi, H., et al. (författare)
  • Beam test results of the polarized gamma-ray observer, PoGOLite
  • 2008
  • Ingår i: 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9. - 9781424427147 ; , s. 732-736
  • Konferensbidrag (refereegranskat)abstract
    • The Polarized Gamma-ray Observer, PoGOLite, is a balloon experiment with the capability of detecting 10% polarization from a 200 mCrab celestial object in the energy range 25 #x2013;80 keV. During a beam test at KEK-PF in February 2008, 20 detector units were assembled, and a 50 keV X-ray beam with a polarization degree of #x223C;90% was irradiated at the center unit. Signals from all 20 units were fed into flightversion electronics consisting of six circuit boards (four waveform digitizer boards, one digital I/O board and one router board) and one microprocessor (SpaceCube), which communicate using a SpaceWire interface. One digitizer board, which can associate up to 8 PDCs, outputs a trigger signal. The digital I/O board handles the trigger and returns a data acquisition request if there is no veto signal (upper or pulse-shape discriminators) from any detector unit. This data acquisition system worked well, and the modulation factor was successfully measured to be #x223C;34%. These results confirmed the capabilities of both detector and data-acquisition system for a pathfinder flight planned in 2010.
  •  
149.
  • Takahashi, H., et al. (författare)
  • The Polarized Gamma-Ray Observer, PoGOLite
  • 2010
  • Ingår i: Transactions of the Japanese Society for Artificial Intelligence, Aerospace Technology Japan. - 1346-0714 .- 1346-0714. ; 8
  • Tidskriftsartikel (refereegranskat)abstract
    • The Polarized Gamma-ray Observer, PoGOLite, is a balloon experiment with the capability of detecting 10% polarization from a 200 mCrab celestial object in the energy-range 25–80 keV. During a beam test at KEK-PF in 2008, 19 detector units and one anti-coincidence detector were assembled, and a 50 keV X-ray beam with a polarization degree of ∼90% was irradiated at the center unit. Signals from all 20 units were fed into flight-version electronics consisting of six circuit boards (four waveform digitizer boards, one digital I/O board and one router board) and one microprocessor (SpaceCube), which communicate using a SpaceWire interface. One digitizer board, which can associate up to 8 detectors, outputs a trigger signal. The digital I/O board handles the trigger and returns a data acquisition request if there is no veto signal (upper or pulse-shape discriminators) from any detector unit. This data acquisition system worked well, and the modulation factor was successfully measured to be ∼34%. These results confirmed the capabilities of the data-acquisition system for a “pathfinder” flight planned in 2010.
  •  
150.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 141-150 av 151
Typ av publikation
tidskriftsartikel (145)
konferensbidrag (5)
rapport (1)
Typ av innehåll
refereegranskat (147)
övrigt vetenskapligt/konstnärligt (4)
Författare/redaktör
Mizuno, T. (112)
Fukazawa, Y. (108)
Longo, F. (102)
Giglietto, N. (102)
Reimer, O. (101)
Morselli, A. (101)
visa fler...
Bastieri, D. (101)
Paneque, D. (100)
Bellazzini, R. (100)
Bruel, P. (100)
Ciprini, S. (100)
Fusco, P. (100)
Gargano, F. (100)
Giordano, F. (100)
Guiriec, S. (100)
Loparco, F. (100)
Raino, S. (100)
Kuss, M. (100)
Reimer, A. (99)
Baldini, L. (99)
Cameron, R. A. (99)
Mazziotta, M. N. (99)
Spinelli, P. (99)
Latronico, L. (99)
Sgrò, C. (99)
Torres, D. F. (98)
Barbiellini, G. (98)
Lubrano, P. (98)
Nuss, E. (98)
Rando, R. (98)
Michelson, P. F. (97)
Orlando, E. (97)
Piron, F. (97)
de Palma, F. (96)
Pesce-Rollins, M. (96)
Bregeon, J. (95)
Caraveo, P. A. (95)
Grenier, I. A. (95)
Lovellette, M. N. (93)
Razzano, M. (93)
Thayer, J. B. (93)
Spandre, G. (93)
Cohen-Tanugi, J. (92)
Moskalenko, I. V. (91)
Funk, S. (90)
Favuzzi, C. (90)
Kamae, T. (90)
Takahashi, H. (89)
Ackermann, M. (88)
Suson, D. J. (88)
visa färre...
Lärosäte
Stockholms universitet (97)
Kungliga Tekniska Högskolan (91)
Linnéuniversitetet (35)
Karolinska Institutet (14)
Uppsala universitet (10)
Lunds universitet (8)
visa fler...
Högskolan Dalarna (7)
Umeå universitet (3)
Göteborgs universitet (1)
Linköpings universitet (1)
visa färre...
Språk
Engelska (151)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (128)
Medicin och hälsovetenskap (6)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy