SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Booleska operatorer måste skrivas med VERSALER

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) ;lar1:(liu)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) > Linköpings universitet

  • Resultat 1-10 av 672
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Ahlander, Britt-Marie, 1954-, et al. (författare)
  • An echo-planar imaging sequence is superior to a steady-state free precession sequence for visual as well as quantitative assessment of cardiac magnetic resonance stress perfusion
  • 2017
  • Ingår i: Clinical Physiology and Functional Imaging. - : Blackwell Publishing. - 1475-0961 .- 1475-097X. ; 37:1, s. 52-61
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: To assess myocardial perfusion, steady-state free precession cardiac magnetic resonance (SSFP, CMR) was compared with gradient-echo-echo-planar imaging (GRE-EPI) using myocardial perfusion scintigraphy (MPS) as reference.METHODS: Cardiac magnetic resonance perfusion was recorded in 30 patients with SSFP and in another 30 patients with GRE-EPI. Timing and extent of inflow delay to the myocardium was visually assessed. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were calculated. Myocardial scar was visualized with a phase-sensitive inversion recovery sequence (PSIR). All scar positive segments were considered pathologic. In MPS, stress and rest images were used as in clinical reporting. The CMR contrast wash-in slope was calculated and compared with the stress score from the MPS examination. CMR scar, CMR perfusion and MPS were assessed separately by one expert for each method who was blinded to other aspects of the study.RESULTS: Visual assessment of CMR had a sensitivity for the detection of an abnormal MPS at 78% (SSFP) versus 91% (GRE-EPI) and a specificity of 58% (SSFP) versus 84% (GRE-EPI). Kappa statistics for SSFP and MPS was 0·29, for GRE-EPI and MPS 0·72. The ANOVA of CMR perfusion slopes for all segments versus MPS score (four levels based on MPS) had correlation r = 0·64 (SSFP) and r = 0·96 (GRE-EPI). SNR was for normal segments 35·63 ± 11·80 (SSFP) and 17·98 ± 8·31 (GRE-EPI), while CNR was 28·79 ± 10·43 (SSFP) and 13·06 ± 7·61 (GRE-EPI).CONCLUSION: GRE-EPI displayed higher agreement with the MPS results than SSFP despite significantly lower signal intensity, SNR and CNR.
  •  
2.
  • Rosendahl, Lene, 1963-, et al. (författare)
  • Computer-assisted calculation of myocardial infarct size shortens the evaluation time of contrast-enhanced cardiac MRI
  • 2008
  • Ingår i: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 28:1, s. 1-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Delayed enhancement magnetic resonance imaging depicts scar in the left ventricle which can be quantitatively measured. Manual segmentation and scar determination is time consuming. The purpose of this study was to evaluate a software for infarct quantification, to compare with manual scar determination, and to measure the time saved.Methods: Delayed enhancement magnetic resonance imaging was performed in 40 patients where myocardial perfusion single photon emission computed tomography imaging showed irreversible uptake reduction suggesting a myocardial scar. After segmentation, the semi-automatic software was applied. A scar area was displayed, which could be corrected and compared with manual delineation. The different time steps were recorded with both methods.Results: The software shortened the average evaluation time by 12.4min per cardiac exam, compared with manual delineation. There was good correlation of myocardial volume, infarct volume and infarct percentage (%) between the two methods, r = 0.95, r = 0.92 and r = 0.91 respectively.Conclusions: A computer software for myocardial volume and infarct size determination cut the evaluation time by more than 50% compared with manual assessment, with maintained clinical accuracy.
  •  
3.
  • Rosendahl, Lene, et al. (författare)
  • Image quality and myocardial scar size determined with magnetic resonance imaging in patients with permanent atrial fibrillation : A comparison of two imaging protocols
  • 2010
  • Ingår i: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 30:2, s. 122-129
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Magnetic resonance imaging (MRI) of the heart generally requires breath holding and a regular rhythm. Single shot 2D steady-state free precession (SS_SSFP) is a fast sequence insensitive to arrhythmia as well as breath holding. Our purpose was to determine image quality, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and infarct size with a fast single shot and a standard segmented MRI sequence in patients with permanent atrial fibrillation and chronic myocardial infarction.Methods: Twenty patients with chronic myocardial infarction and ongoing atrial fibrillation were examined with inversion recovery SS_SSFP and segmented inversion recovery 2D fast gradient echo (IR_FGRE). Image quality was assessed in four categories: delineation of infarcted and non-infarcted myocardium, occurrence of artefacts and overall image quality. SNR and CNR were calculated. Myocardial volume (ml) and infarct size, expressed as volume (ml) and extent (%), were calculated, and the methodological error was assessed.Results: SS_SSFP had significantly better quality scores in all categories (P = 0·037, P = 0·014, P = 0·021, P = 0·03). SNRinfarct and SNRblood were significantly better for IR_FGRE than for SS_SSFP (P = 0·048, P = 0·018). No significant difference was found in SNRmyocardium and CNR. The myocardial volume was significantly larger with SS_SSFP (170·7 versus 159·2 ml, P<0·001), but no significant difference was found in infarct volume and infarct extent.Conclusion: SS_SSFP displayed significantly better image quality than IR_FGRE. The infarct size and the error in its determination were equal for both sequences, and the examination time was shorter with SS_SSFP.
  •  
4.
  • Andersson, Elisabeth, et al. (författare)
  • Surveillance of indeterminate pulmonary nodules detected with CT in a Swedish population-based study (SCAPIS) : Psychosocial consequences and impact on health-related quality of life - A multicentre prospective cross-sectional study
  • 2021
  • Ingår i: BMJ Open. - : BMJ Publishing Group Ltd. - 2044-6055. ; 11:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: To investigate whether surveillance of pulmonary nodules detected with low-dose CT (LDCT) impacted health-related quality of life and psychosocial consequences in the Swedish population-based study, Swedish CArdioPulmonary bioImage Study (SCAPIS).Design: A prospective cross-sectional study.Settings and participants: This multicentre (five sites) observational study, which included a cohort from SCAPIS, consisted of 632 participants with indeterminate pulmonary nodules detected with LDCT. These participants continued surveillance for up to 36 months, during which lung cancer was not detected (surveillance group). Additionally, 972 participants with a negative pulmonary LDCT scan were included as a control group. Matching criteria were LDCT date (±2 weeks), gender and site.Outcome measures: All participants completed a health-related quality of life questionnaire (RAND-36) and the Consequences of Screening (COS) questionnaire, an average of 3 years after LDCT was conducted at entry into SCAPIS.Results: Participants were 51-70 years old at study commencement. Overall, the two groups did not differ in demographic or psychosocial variables, smoking habits or pulmonary medical history. Individuals from countries other than Sweden and those with low socioeconomic status were less likely to participate (p<0.001). No effects on health-related quality of life were observed via RAND-36. In COS, the surveillance group demonstrated a higher OR for anxiety about lung cancer (OR 3.96, 95% CI 2.35 to 6.66, p<0.001), experiencing a sense of dejection (OR 1.35, 95% CI 1.06 to 1.72, p=0.015) and thoughts about existential values (OR 1.30, 95% CI 1.04 to 1.60, p=0.018).Conclusions: Lung surveillance with LDCT contributed to significant experiences of sense of dejection, anxiety about lung cancer and development of thoughts about existential values among participants in the surveillance group compared with the controls. The risk of side effects should be communicated for informed decision-making about (non-)attendance in lung cancer screening.
  •  
5.
  • Ahlander, Britt-Marie, 1954-, et al. (författare)
  • Development and validation of a questionnaire evaluating patient anxiety during Magnetic Resonance Imaging : the Magnetic Resonance Imaging- Anxiety Questionnaire (MRI-AQ)
  • 2016
  • Ingår i: Journal of Advanced Nursing. - : Wiley-Blackwell. - 0309-2402 .- 1365-2648. ; 72:6, s. 1368-1380
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: To develop and validate a new instrument measuring patient anxiety during Magnetic Resonance Imaging examinations, Magnetic Resonance Imaging-Anxiety Questionnaire.Background: Questionnaires measuring patients’ anxiety during Magnetic Resonance Imaging examinations have been the same as used in a wide range of conditions. To learn about patients’ experience during examination and to evaluate interventions, a specific questionnaire measuring patient anxiety during Magnetic Resonance Imaging is needed.Design: Psychometric cross-sectional study with test-retest design.Methods: A new questionnaire, Magnetic Resonance Imaging-Anxiety Questionnaire, was designed from patient expressions of anxiety in Magnetic Resonance Imagingscanners. The sample was recruited between October 2012–October 2014. Factor structure was evaluated with exploratory factor analysis and internal consistency with Cronbach’s alpha. Criterion-related validity, known-group validity and test-retest was calculated.Results: Patients referred for Magnetic Resonance Imaging of either the spine or the heart, were invited to participate. The development and validation of Magnetic Resonance Imaging-Anxiety Questionnaire resulted in 15 items consisting of two factors. Cronbach’s alpha was found to be high. Magnetic Resonance Imaging-Anxiety Questionnaire correlated higher with instruments measuring anxiety than with depression scales. Known-group validity demonstrated a higher level of anxiety for patients undergoing Magnetic Resonance Imaging scan of the heart than for those examining the spine. Test-retest reliability demonstrated acceptable level for the scale.Conclusion: Magnetic Resonance Imaging-Anxiety Questionnaire bridges a gap among existing questionnaires, making it a simple and useful tool for measuring patient anxiety during Magnetic Resonance Imaging examinations.
  •  
6.
  • Nyholm, Tufve, et al. (författare)
  • A national approach for automated collection of standardized and population-based radiation therapy data in Sweden
  • 2016
  • Ingår i: Radiotherapy and Oncology. - : Elsevier BV. - 0167-8140 .- 1879-0887. ; 119:2, s. 344-350
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To develop an infrastructure for structured and automated collection of interoperable radiation therapy (RT) data into a national clinical quality registry. Materials and methods: The present study was initiated in 2012 with the participation of seven of the 15 hospital departments delivering RT in Sweden. A national RT nomenclature and a database for structured unified storage of RT data at each site (Medical Information Quality Archive, MIQA) have been developed. Aggregated data from the MIQA databases are sent to a national RT registry located on the same IT platform (INCA) as the national clinical cancer registries. Results: The suggested naming convention has to date been integrated into the clinical workflow at 12 of 15 sites, and MIQA is installed at six of these. Involvement of the remaining 3/15 RT departments is ongoing, and they are expected to be part of the infrastructure by 2016. RT data collection from ARIA (R), Mosaiq (R), Eclipse (TM), and Oncentra (R) is supported. Manual curation of RT-structure information is needed for approximately 10% of target volumes, but rarely for normal tissue structures, demonstrating a good compliance to the RT nomenclature. Aggregated dose/volume descriptors are calculated based on the information in MIQA and sent to INCA using a dedicated service (MIQA2INCA). Correct linkage of data for each patient to the clinical cancer registries on the INCA platform is assured by the unique Swedish personal identity number. Conclusions: An infrastructure for structured and automated prospective collection of syntactically inter operable RT data into a national clinical quality registry for RT data is under implementation. Future developments include adapting MIQA to other treatment modalities (e.g. proton therapy and brachytherapy) and finding strategies to harmonize structure delineations. How the RT registry should comply with domain-specific ontologies such as the Radiation Oncology Ontology (ROO) is under discussion.
  •  
7.
  • Klintström, Eva, et al. (författare)
  • Trabecular bone microstructure analysis on data from a novel twin robotic X-ray device
  • 2023
  • Ingår i: Acta Radiologica. - : SAGE Publications. - 0284-1851 .- 1600-0455. ; 64:4, s. 1566-1572
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Bone strength is related to both mineral density (BMD) and the bone microstructure. However, only the assessment of BMD is available in clinical routine care today. Purpose: To analyze and study the correlation of trabecular bone microstructure from the imaging data of a prototype Multitom Rax system, using micro-computed tomography (CT) data as the reference method (Skyscan 1176).Material and Methods: Imaging data from 14 bone samples from the human radius were analyzed regarding six bone structure parameters, i.e. trabecular nodes, separation, spacing, and thickness as well as bone volume (BV/TV) and structural model index (SMI).Results: All six structure parameters showed strong correlations to micro-CT with Spearman correlation coefficients in the range of 0.83–0.93. BV/TV and SMI had a correlation >0.90. Two of the parameters, namely, separation and number, had mean values in the same range as micro-CT. The other four were either over- or underestimated.Conclusion: The strong correlation between micro-CT and the clinical imaging system, indicates the possibility for analyzing bone microstructure with potential to add value in fracture assessment using the studied device in a clinical workflow. 
  •  
8.
  • Ahlander, Britt-Marie, 1954- (författare)
  • Magnetic Resonance Imaging of the Heart : Image quality, measurement accuracy and patient experience
  • 2016
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • Background: Non-invasive diagnostic imaging of atherosclerotic coronary artery disease (CAD) is frequently carried out with cardiovascular magnetic resonance imaging (CMR) or myocardial perfusion single photon emission computed tomography (MPS). CMR is the gold standard for the evaluation of scar after myocardial infarction and MPS the clinical gold standard for ischemia. Magnetic Resonance Imaging (MRI) is at times difficult for patients and may induce anxiety while patient experience of MPS is largely unknown.Aims: To evaluate image quality in CMR with respect to the sequences employed, the influence of atrial fibrillation, myocardial perfusion and the impact of patient information. Further, to study patient experience in relation to MRI with the goal of improving the care of these patients.Method: Four study designs have been used. In paper I, experimental cross-over, paper (II) experimental controlled clinical trial, paper (III) psychometric crosssectional study and paper (IV) prospective intervention study. A total of 475 patients ≥ 18 years with primarily cardiac problems (I-IV) except for those referred for MRI of the spine (III) were included in the four studies.Result: In patients (n=20) with atrial fibrillation, a single shot steady state free precession (SS-SSFP) sequence showed significantly better image quality than the standard segmented inversion recovery fast gradient echo (IR-FGRE) sequence (I). In first-pass perfusion imaging the gradient echo-echo planar imaging sequence (GREEPI) (n=30) had lower signal-to-noise and contrast–to-noise ratios than the steady state free precession sequence (SSFP) (n=30) but displayed a higher correlation with the MPS results, evaluated both qualitatively and quantitatively (II). The MRIAnxiety Questionnaire (MRI-AQ) was validated on patients, referred for MRI of either the spine (n=193) or the heart (n=54). The final instrument had 15 items divided in two factors regarding Anxiety and Relaxation. The instrument was found to have satisfactory psychometric properties (III). Patients who prior CMR viewed an information video scored significantly (lower) better in the factor Relaxation, than those who received standard information. Patients who underwent MPS scored lower on both factors, Anxiety and Relaxation. The extra video information had no effect on CMR image quality (IV).Conclusion: Single shot imaging in atrial fibrillation produced images with less artefact than a segmented sequence. In first-pass perfusion imaging, the sequence GRE-EPI was superior to SSFP. A questionnaire depicting anxiety during MRI showed that video information prior to imaging helped patients relax but did not result in an improvement in image quality.
  •  
9.
  • Romu, Thobias, et al. (författare)
  • Characterization of Brown Adipose Tissue by Water-Fat Separated Magnetic Resonance Imaging
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 42:6, s. 1639-1645
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To evaluate the possibility of quantifying brown adipose tissue (BAT) volume and fat concentration with a high resolution, long echo time, dual-echo Dixon imaging protocol. Methods: A 0.42 mm isotropic resolution water-fat separated MRI protocol was implemented by using the second opposite-phase echo and third in-phase echo. Fat images were calibrated with regard to the intensity of nearby white adipose tissue (WAT) to form relative fat content (RFC) images. To evaluate the ability to measure BAT volume and RFC contrast dynamics, rats were divided into two groups that were kept at 48 or 22 degrees C for 5 days. The rats were then scanned in a 70 cm bore 3.0 Tesla MRI scanner and a human dual energy CT. Interscapular, paraaortal, and perirenal BAT (i/pa/pr-BAT) depots as well as WAT and muscle were segmented in the MRI and CT images. Biopsies were collected from the identified BAT depots. Results: The biopsies confirmed that the three depots identified with the RFC images consisted of BAT. There was a significant linear correlation (P< 0.001) between the measured RFC and the Hounsfield units from DECT. Significantly lower iBAT RFC (P=0.0064) and significantly larger iBAT and prBAT volumes (P=0.0017) were observed in the cold stimulated rats. Conclusion: The calibrated Dixon images with RFC scaling can depict BAT and be used to measure differences in volume, and fat concentration, induced by cold stimulation. The high correlation between RFC and HU suggests that the fat concentration is the main RFC image contrast mechanism.
  •  
10.
  • Wang, Chunliang, 1980-, et al. (författare)
  • An interactive software module for visualizing coronary arteries in CT angiography
  • 2008
  • Ingår i: International Journal of Computer Assisted Radiology and Surgery. - Heidelberg/Berlin : Springer. - 1861-6410 .- 1861-6429. ; 3:1-2, s. 11-18
  • Tidskriftsartikel (refereegranskat)abstract
    • A new software module for coronary artery segmentation and visualization in CT angiography (CTA) datasets is presented, which aims to interactively segment coronary arteries and visualize them in 3D with maximum intensity projection (MIP) and volume rendering (VRT).Materials and Methods:  The software was built as a plug-in for the open-source PACS workstation OsiriX. The main segmentation function is based an optimized “virtual contrast injection” algorithm, which uses fuzzy connectedness of the vessel lumen to separate the contrast-filled structures from each other. The software was evaluated in 42 clinical coronary CTA datasets acquired with 64-slice CT using isotropic voxels of 0.3–0.5 mm.Results:  The median processing time was 6.4 min, and 100% of main branches (right coronary artery, left circumflex artery and left anterior descending artery) and 86.9% (219/252) of visible minor branches were intact. Visually correct centerlines were obtained automatically in 94.7% (321/339) of the intact branches.Conclusion:  The new software is a promising tool for coronary CTA post-processing providing good overviews of the coronary artery with limited user interaction on low-end hardware, and the coronary CTA diagnosis procedure could potentially be more time-efficient than using thin-slab technique.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 672
Typ av publikation
tidskriftsartikel (420)
konferensbidrag (117)
rapport (56)
doktorsavhandling (37)
forskningsöversikt (18)
annan publikation (12)
visa fler...
bokkapitel (5)
licentiatavhandling (5)
samlingsverk (redaktörskap) (1)
patent (1)
visa färre...
Typ av innehåll
refereegranskat (473)
övrigt vetenskapligt/konstnärligt (194)
populärvet., debatt m.m. (1)
Författare/redaktör
Lundberg, Peter (54)
Borga, Magnus (52)
Alm Carlsson, Gudrun (51)
Dahlqvist Leinhard, ... (36)
Romu, Thobias (35)
Sandborg, Michael (34)
visa fler...
Dahlqvist Leinhard, ... (33)
Persson, Anders (31)
Sandborg, Michael, 1 ... (29)
Carlsson Tedgren, Ås ... (26)
Smedby, Örjan (24)
Engvall, Jan (22)
Vogel, HJ (16)
Ebbers, Tino (15)
Lund, Eva (14)
Dasu, Alexandru (14)
West, Janne (14)
Smedby, Örjan, 1956- (13)
Eklund, Anders, 1981 ... (13)
Larsson, Elna-Marie (12)
Pettersson, Håkan (12)
Forsgren, Mikael (12)
Dyverfeldt, Petter (12)
Linge, Jennifer (12)
Lundberg, Peter, 195 ... (11)
Karlsson, Anette (11)
Kihlberg, Johan (11)
Warntjes, Marcel Jan ... (11)
Kechagias, Stergios (10)
Smedby, Örjan, Profe ... (10)
Brismar, Torkel (10)
Moreno, Rodrigo, 197 ... (10)
Klintström, Eva (10)
Persson, Anders, 195 ... (10)
Alm Carlsson, Gudrun ... (9)
Knutsson, Hans (9)
Bell, Jimmy (9)
Smedby, Örjan, Profe ... (9)
Tisell, Anders, 1981 ... (8)
Landtblom, Anne-Mari ... (8)
Carlsson Tedgren, Ås ... (8)
Nilsson, Markus (8)
Länne, Toste (8)
Toma-Daşu, Iuliana (8)
Rydén Ahlgren, Åsa (8)
Persliden, Jan (8)
Båth, Magnus, 1974 (8)
Tisell, Anders (8)
Woisetschläger, Misc ... (8)
Dahlström, Nils, 196 ... (8)
visa färre...
Lärosäte
Karolinska Institutet (96)
Lunds universitet (85)
Uppsala universitet (57)
Göteborgs universitet (48)
Kungliga Tekniska Högskolan (32)
visa fler...
Örebro universitet (26)
Umeå universitet (23)
Stockholms universitet (16)
Jönköping University (7)
Chalmers tekniska högskola (3)
Linnéuniversitetet (2)
Luleå tekniska universitet (1)
Malmö universitet (1)
Handelshögskolan i Stockholm (1)
visa färre...
Språk
Engelska (632)
Svenska (39)
Spanska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (672)
Teknik (116)
Naturvetenskap (46)
Samhällsvetenskap (5)
Humaniora (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy