SwePub
Sök i SwePub databas

  Utökad sökning

Booleska operatorer måste skrivas med VERSALER

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) ;lar1:(mau)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) > Malmö universitet

  • Resultat 1-10 av 49
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Grote, Ludger, 1964, et al. (författare)
  • National Knowledge-Driven Management of Obstructive Sleep Apnea-The Swedish Approach
  • 2023
  • Ingår i: Diagnostics. - : MDPI AG. - 2075-4418. ; 13:6
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: This paper describes the development of "Swedish Guidelines for OSA treatment" and the underlying managed care process. The Apnea Hypopnea Index (AHI) is traditionally used as a single parameter for obstructive sleep apnea (OSA) severity classification, although poorly associated with symptomatology and outcome. We instead implement a novel matrix for shared treatment decisions based on available evidence. Methods: A national expert group including medical and dental specialists, nurses, and patient representatives developed the knowledge-driven management model. A Delphi round was performed amongst experts from all Swedish regions (N = 24). Evidence reflecting treatment effects was extracted from systematic reviews, meta-analyses, and randomized clinical trials. Results: The treatment decision in the process includes a matrix with five categories from a "very weak"" to "very strong" indication to treat, and it includes factors with potential influence on outcome, including (A) OSA-related symptoms, (B) cardiometabolic comorbidities, (C) frequency of respiratory events, and (D) age. OSA-related symptoms indicate a strong incitement to treat, whereas the absence of symptoms, age above 65 years, and no or well-controlled comorbidities indicate a weak treatment indication, irrespective of AHI. Conclusions: The novel treatment matrix is based on the effects of treatments rather than the actual frequency of respiratory events during sleep. A nationwide implementation of this matrix is ongoing, and the outcome is monitored in a prospective evaluation by means of the Swedish Sleep Apnea Registry (SESAR).
  •  
2.
  • Brown, J, et al. (författare)
  • Basic training requirements for the use of dental CBCT by dentists : a position paper prepared by the European Academy of DentoMaxilloFacial Radiology
  • 2014
  • Ingår i: Dento-Maxillo-Facial Radiology. - : British Institute of Radiology. - 0250-832X .- 1476-542X. ; 43:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Cone beam CT (CBCT) is a relatively new imaging modality, which is now widely available to dentists for examining hard tissues in the dental and maxillofacial regions. CBCT gives a three-dimensional depiction of anatomy and pathology, which is similar to medical CT and uses doses generally higher than those used in conventional dental imaging. The European Academy of DentoMaxilloFacial Radiology recognizes that dentists receive training in two-dimensional dental imaging as undergraduates, but most of them have received little or no training in the application and interpretation of cross-sectional three-dimensional imaging. This document identifies the roles of dentists involved in the use of CBCT, examines the training requirements for the justification, acquisition and interpretation of CBCT imaging and makes recommendations for further training of dentists in Europe who intend to be involved in any aspect of CBCT imaging. Two levels of training are recognized. Level 1 is intended to train dentists who prescribe CBCT imaging, such that they may request appropriately and understand the resultant reported images. Level 2 is intended to train to a more advanced level and covers the understanding and skills needed to justify, carry out and interpret a CBCT examination. These recommendations are not intended to create specialists in CBCT imaging but to offer guidance on the training of all dentists to enable the safe use of CBCT in the dentoalveolar region.
  •  
3.
  • Bryndahl, Fredrik, et al. (författare)
  • Cartilage changes link retrognathic mandibular growth to TMJ disc displacement in a rabbit model
  • 2011
  • Ingår i: International Journal of Oral and Maxillofacial Surgery. - : Elsevier. - 0901-5027 .- 1399-0020. ; 40:6, s. 621-627
  • Tidskriftsartikel (refereegranskat)abstract
    • Recent experimental research demonstrated that non-reducing temporomandibular joint (TMJ) disc displacement in growing rabbits impaired mandibular growth. TMJ disc displacement is also shown to induce histological changes of the condylar cartilage. The authors hypothesized that the severity of these changes would correlate to the magnitude of mandibular growth. Bilateral non-reducing TMJ disc displacement was surgically created in 10 growing New Zealand White rabbits. Ten additional rabbits constituted a sham operated control group. Aided by tantalum implants, growth was cephalometrically determined for each mandibular side during a period equivalent to childhood and adolescence in man. At the end of the growth period, histologically classified cartilage features were correlated with the assessed ipsilateral mandibular growth. Non-reducing displacement of the TMJ disc during the growth period induced histological reactions of the condylar cartilage in the rabbit model. The severity of cartilage changes was inversely correlated to the magnitude and the direction of mandibular growth, which resulted in a retrognathic growth pattern.
  •  
4.
  • Salé, Hanna, et al. (författare)
  • Temporomandibular Joints in Asymptomatic and Symptomatic Nonpatient Volunteers : A Prospective 15-Year Follow-Up Clinical and MR Imaging Study
  • 2013
  • Ingår i: Radiology. - : Radiological Society of North America. - 0033-8419 .- 1527-1315. ; 267:1, s. 183-194
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To determine the incidence, prevalence, and progression of temporomandibular joint (TMJ) magnetic resonance (MR) imaging findings and symptoms during 15 years in adult asymptomatic and symptomatic volunteers (nonpatients). Materials and Methods: A regional committee for medical research ethics approved the study, and informed volunteer consent was obtained. Fifty-three volunteers were examined at study inception. For clinical assessment, a self-administered questionnaire was given, followed by an interview with each volunteer at study inception, at 1 year later, and at 15 years later. Bilateral TMJ MR imaging and clinical examination were performed at inception and at 15-year follow-up. The MR images were assessed for disk position, bone status, and joint fluid. All 53 volunteers participated at 1-year follow-up, and 50 of 53 volunteers participated at 15-year follow-up; of these 50 volunteers, 47 underwent MR imaging. The Fisher exact test was used to determine differences between groups, and the Wilcoxon signed-rank test was used to determine differences in prevalence of TMJ symptoms among the three examination times. Results: At study inception, TMJ disk displacement was observed in 31% of asymptomatic volunteers (nine of 29) compared with 89% of symptomatic volunteers (16 of 18, P < .001). Inceptive TMJ status was maintained after 15 years in 91% (43 of 47). Unilateral progression was observed in four volunteers (9%); one was symptomatic and three were asymptomatic. Progression involved development of new disk displacement (n = 1), development of new bone changes (n = 2), and aggravation from reducing to non-reducing disk displacement (n = 1). Prevalence of TMJ symptoms did not change significantly between examination times (P = .77). TMJ clicking was the most common clinical symptom. Conclusion: Volunteers with mild symptoms had a prevalence of disk displacement of the same magnitude as that reported in patients, although most volunteers, symptomatic as well as asymptomatic, maintained their TMJ status during 15 years. (C)RSNA, 2012
  •  
5.
  • Olsson, Lars, et al. (författare)
  • The effect of anatomical noise on perception of low contrast in intra-oral radiographs : an in vitro study
  • 2016
  • Ingår i: Dento-Maxillo-Facial Radiology. - London, United Kingdom : British Institute of Radiology. - 0250-832X .- 1476-542X. ; 45:4
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: Radiographic images suffer from varying amounts of noise. The most studied and discussed of these is random noise. However, recent research has shown that the projected anatomy contributes substantially to noise, especially when detecting low-contrast objects in the images. Our aim, therefore, was to evaluate the extent to which overprojected anatomical noise affects the detection of low-contrast objects in intra-oral images.Methods: Our study used four common sensor models. With each sensor, we took four series of images, three series with and one series without an anatomical phantom present. In each series, we exposed a low-contrast phantom at 18 different exposure times using a standardized method. 4 observers evaluated all 288 images.Results: The low-contrast characteristics differed substantially when imaging low contrast on a homogeneous background compared with imaging low contrast when an anatomical phantom was present. For three of the sensors, optimal exposure times for low-contrast imaging were found, while the fourth sensor displayed a completely different behaviour.Conclusions: Calibrating the low-contrast properties of an imaging system using low-contrast objects on a homogeneous background is not recommended. On an anatomical background, low-contrast properties are completely different, and these will mimic the clinical situation much more closely, directing the operator how to best use the system. There is a clear demand for further research on this subject.
  •  
6.
  • Bladh, Magnus, et al. (författare)
  • Defined shapes of carotid artery calcifications on panoramic radiographs correlate with specific signs of cardiovascular disease on ultrasound examination
  • 2024
  • Ingår i: Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology. - : Elsevier. - 2212-4403 .- 2212-4411.
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: The aim was to optimize diagnostics for carotid artery calcifications (CACs) on panoramic radiographs (PRs) to identify cardiovascular disease (CVD) by investigating how 4 defined CAC shapes are associated with ultrasound (US) findings indicating CVD. Study Design: The study included 414 participants (802 neck sides) from the Malmö Offspring Dental Study, examined with PRs. The PRs were assessed for CAC shapes stratified into 4 categories: single, scattered, vessel-width defining, and vessel-outlining. The carotid arteries were examined with US for signs of CVD: the presence of plaques, largest individual area of a plaque, number of plaques, and percentage reduction of the lumen. Associations between the different CAC categories and US characteristics were analyzed. Results: All categories of CAC were significantly associated with a higher degree of US findings indicating CVD compared with no CAC (P < .001). The most significant differences were found for vessel-outlining CAC, with the mean of the largest individual plaque area of 17.9 vs 2.3 mm2, mean number of plaques 1.6 vs 0.2, and mean percentage reduction of the lumen 24.1% vs 3.5% (all P < .001). Conclusions: Independent of shape, CACs detected on PRs were associated with a higher degree of US findings of CVD. This was most pronounced for vessel-outlining CAC. With refined differential diagnostics of CACs in PRs, dentists may contribute to improved identification of patients in need of cardiovascular prevention.
  •  
7.
  • Hellén-Halme, Kristina, et al. (författare)
  • Comparison of the performance of intraoral X-ray sensors using objective image quality assessment
  • 2016
  • Ingår i: Oral surgery, oral medicine, oral pathology and oral radiology. - : Elsevier. - 2212-4403 .- 2212-4411. ; 121:5, s. e129-e137
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives. The main aim of this study was to evaluate the performance of 10 individual sensors of the same make, using objective measures of key image quality parameters. A further aim was to compare 8 brands of sensors. Study Design. Ten new sensors of 8 different models from 6 manufacturers (i.e., 80 sensors) were included in the study. All sensors were exposed in a standardized way using an X-ray tube voltage of 60 kVp and different exposure times. Sensor response, noise, low-contrast resolution, spatial resolution and uniformity were measured Results. Individual differences between sensors of the same brand were surprisingly large in some cases. There were clear differences in the characteristics of the different brands of sensors. The largest variations were found for individual sensor response for some of the brands studied. Also, noise level and low contrast resolution showed large variations between brands Conclusions. Sensors, even of the same brand, vary significantly in their quality. It is thus valuable to establish action levels for the acceptance of newly delivered sensors and to use objective image quality control for commissioning purposes and periodic checks to ensure high performance of individual digital sensors.
  •  
8.
  • Sonesson, Mikael, et al. (författare)
  • Orthodontic appliances and MR image artefacts : An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners
  • 2021
  • Ingår i: Imaging Science in Dentistry. - : Korean Academy of Oral and Maxillofacial Radiology. - 2233-7822 .- 2233-7830. ; 51
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.(Imaging Sci Dent 20200199)
  •  
9.
  • Bergkvist, Göran, et al. (författare)
  • Bone Density at Implant Sites and Its Relationship to Assessment of Bone Quality and Treatment Outcome
  • 2010
  • Ingår i: INTERNATIONAL JOURNAL OF ORAL and MAXILLOFACIAL IMPLANTS. - : Quintessence Publishing Co, Inc. - 0882-2786 .- 1942-4434. ; 25:2, s. 321-328
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the relationship between bone mineral density (BMD) before implant placement, implant stability measures at implant placement, and marginal bone loss of immediately loaded implants after 1 year in situ. Materials and Methods: Consecutively recruited patients received Straumann SLActive implants loaded with fixed provisional prostheses within 24 hours. BMD was measured from computed tomographic images before implant placement. Alveolar bone quality was assessed during surgery. Implant stability-both rotational and as measured with resonance frequency analysis- and marginal bone height were assessed at implant placement and after 1 year. The Pearson correlation coefficient was used to calculate correlations, and significance was considered when P andlt; .05. Results: Twenty-one patients received 137 implants (87 in maxillae and 50 in mandibles). BMD was significantly correlated with bone quality classification in both arches (P andlt; .001). Mean BMD was also significantly correlated with stability values (P andlt; .001). Mean marginal bone loss at implant surfaces differed, but not significantly, at the 1-year follow-up, regardless of BMD values (P = .086) and measured stability (rotational stability P = .34, resonance frequency analysis P = .43) at implant placement. Conclusion: Within the limits of this study, it can be concluded that computed tomographic examination can be used as a preoperative method to assess jawbone density before implant placement, since density values correlate with prevailing methods of measuring implant stability. However, in the short time perspective of 1 year, there were no differences in survival rates or changes in marginal bone level between implants placed in bone tissue of different density.
  •  
10.
  • Thorsson, Ola, et al. (författare)
  • Advantages of standardized criteria for the interpretation of angiotensin-converting enzyme inhibition renography
  • 2009
  • Ingår i: NUCLEAR MEDICINE COMMUNICATIONS. - 0143-3636 .- 1473-5628. ; 30, s. 449-454
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The aim of this study was to evaluate the efficiency of captopril renography to detect renovascular hypertension (RVH) using the standardized test criteria established at the consensus conference in Santa Fe 1995. The evaluation was made prospectively and in a clinical situation.less thanpgreater thanMethods Renal scintigraphy was performed with Tc-99m-MAG3 according to a 2-day protocol in patients receiving 25 mg captopril 1 h before the test. A baseline study was added only in patients showing abnormal findings in the captopril-stimulated study. All tests were re-evaluated according to the consensus criteria by two nuclear medicine specialists who were unaware of the original evaluation that was made by different doctors on duty at the nuclear medicine section at the time.less than/pgreater than less thanpgreater thanResults Using a 12-month clinical follow-up as a reference, 16 patients in a group of 164 hypertensive patients had RVH, that is, a prevalence of 10%. The re-evaluation and original evaluation indicated a sensitivity of 94 versus 100%, specificity of 97 versus 88%, accuracy of 97 versus 89%, positive predictive value of 83 versus 47%, and negative predictive value of 99 versus 100%. In 15 studies, results from the two evaluations were discordant and in 14 of these studies an originally false positive or intermediate study was re-evaluated as negative. The test result was highly decisive in the future management of patients, minimizing the number of renal angiograms that had to be performed and initiating a search for other causes of secondary hypertension. Conclusion Captopril renography is a useful and reliable test in patients with suspicion of RVH. Strict adherence to the diagnostic criteria and recommendations from the 1995 consensus conference further improved the performance of the test compared with clinical follow-up.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 49
Typ av publikation
tidskriftsartikel (36)
konferensbidrag (10)
doktorsavhandling (1)
forskningsöversikt (1)
bokkapitel (1)
Typ av innehåll
refereegranskat (38)
övrigt vetenskapligt/konstnärligt (7)
populärvet., debatt m.m. (4)
Författare/redaktör
Lindh, Christina (16)
Horner, Keith (8)
Nilsson, Mats (6)
Rohlin, Madeleine (4)
Petersson, Arne (3)
Graham, Jim (3)
visa fler...
Bondemark, Lars (2)
Strand, Sven-Erik (2)
Åkerström, Bo (2)
Alstergren, Per (2)
Hellborg, Ragnar (2)
Friberg, Danielle (1)
Eriksson, Lars (1)
Brown, J. (1)
Engström, Gunnar (1)
Galli, Silvia (1)
Abdulraheem, Salem (1)
Sonesson, Mikael (1)
Ekman, Jörgen (1)
Jacobs, R. (1)
Marsal, Karel (1)
Warfvinge, Gunnar (1)
Sundgren, Pia C. (1)
Gunnarsson, Mikael (1)
Nilsson, Peter M (1)
Svensson, Peter (1)
Boonen, Steven (1)
Helou, Khalil, 1966 (1)
Olsson, Lars (1)
Skog, Göran (1)
Stenström, Kristina (1)
Mattsson, Sören (1)
Fischer, Johannes (1)
Gram, Magnus (1)
Forssell-Aronsson, E ... (1)
Isberg, Annika (1)
Levring Jäghagen, Ev ... (1)
Lindström, Johan (1)
Thorsson, Ola (1)
Sajavaara, Timo (1)
Theorell-Haglöw, Jen ... (1)
Westergren, Hans (1)
Cheng, Yuanji (1)
Salé, Hanna (1)
Alexander, Louise (1)
Schulze, D. (1)
Jujic, Amra (1)
Larsson, Jörgen (1)
Allen, P Danny (1)
Farnell, Damian J (1)
visa färre...
Lärosäte
Lunds universitet (15)
Umeå universitet (4)
Linköpings universitet (3)
Karolinska Institutet (3)
Göteborgs universitet (2)
visa fler...
Uppsala universitet (1)
Örebro universitet (1)
visa färre...
Språk
Engelska (46)
Svenska (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (49)
Naturvetenskap (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy