SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Booleska operatorer måste skrivas med VERSALER

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) ;pers:(Lundberg Peter)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) > Lundberg Peter

  • Resultat 1-10 av 74
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Lundberg, Peter, et al. (författare)
  • Kvantifiering av leversteatos: diagnostisk utvärdering av protonmagnetresonansspektroskopi jämfört med histologiska metoder
  • 2016
  • Konferensbidrag (refereegranskat)abstract
    • BakgrundLeversteatos är den vanligaste manifestationen av leversjukdom i västvärlden. Leverbiopsi med semikvantitativ histologisk gradering är referensmetod vid gradering av leversteatos. Med protonmagnetsresonansspektroskopi (1H-MRS), en metod som föreslagits ersätta leverbiopsi för värdering av steatos, kan leverns innehåll av triglycerider mätas icke-invasivt. Triglyceridinnehåll >5,00 % används ofta som ett diagnostiskt kriterium för leversteatos vid undersökning med 1H-MRS. Syftet med studien var att jämföra 1H-MRS med semikvantitativ histologisk steatosgradering och kvantitativ histologisk steatosmätning.MetodPatienter remitterade för utredning av förhöjda leverenzymer in-kluderades i studien. Samtliga patienter genomgick klinisk undersökning, laboratorieprovtagning samt 1H-MRS direkt följd av leverbiopsi. För konventionell histologisk semikvantitativ gradering av steatos användes kriterierna utarbetade av Brunt och medarbetare. Kvantitativ mätning av fett i biopsierna utfördes genom att med hjälp av stereologisk punkträkning (SPC) mäta andelen av ytan som innehöll fettvakuoler.ResultatI studien inkluderades 94 patienter, varav 37 hade icke-alkoholor-sakad fettleversjukdom (NAFLD), 49 hade andra leversjukdomar och 8 hade normal leverbiopsi. En stark korrelation noterades mel-lan 1H-MRS och SPC (r=0,92, p<0,0001; к=0.82). Korrelationen mellan 1H-MRS och Brunts kriterier (к=0.26) samt mellan SPC och Brunts kriterier (к=0.38) var betydligt sämre. När patologens gradering (Brunts kriterier) användes som referensmetod för diag-nos av leversteatos så hade alla patienter med triglyceridinnehåll >5,00 % mätt med 1H-MRS steatos (specificitet 100 %). Emellertid hade 22 av 69 patienter med triglyceridinnehåll ≤5,00 % också le-versteatos enligt Brunts kriterier (sensitivitet 53 %). Motsvarande siffror när man använde gränsvärdet 3,02 % var sensitivitet 79 % och specificitet 100 %. Vid ytterligare reduktion av gränsvärdet för triglyceridinnehåll till 2,00 % ökade sensitiviteten till 87 % med upprätthållande av hög specificitet (94 %).Slutsats1H-MRS och SPC uppvisade en mycket hög korrelation vid kvantifiering av leversteatos. SPC borde därför föredras framför Brunts kriterier när noggrann histologisk kvantifiering av leversteatos är önskvärd. Många patienter kan ha histologisk leversteatos trots triglyceridinnehåll ≤5,00 % mätt med 1H-MRS. Gränsvärdet för diagnostisering av leversteatos med 1H-MRS bör därför reduceras.
  •  
3.
  • Karlsson, Markus, et al. (författare)
  • Increased bile excretion of Gd-EOB-DTPA in diffuse liver disease : mechanistic modeling of qDCE-MRI in patients with severe fibro-sis
  • 2016
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - : Springer. - 0968-5243 .- 1352-8661. ; 29:1, s. S272-S273
  • Tidskriftsartikel (refereegranskat)abstract
    • IntroductionOver the past decades, several different non-invasive methods for staging hepatic fibrosis have been proposed. One such method is dynamic contrast enhanced MRI (DCE-MRI) using the contrast agent (CA) Gd-EOB-DTPA. Gd-EOB-DTPA is liver specific, which means that it is taken up specifically by the hepatocytes via the OATP3B1/B3 transporters and excreted into the bile via the MRP2 transporter. Several studies have shown that DCE-MRI and Gd-EOBDTPA can separate patients with advanced (F3-F4) from mild (F0-F2) hepatic fibrosis by measuring the signal intensity, where patients with advanced fibrosis have a lower signal intensity than the mild fibrosis cases.1 However, none of the studies up to date have been able to differentiate if the reduced signal intensity in the liver is because of an decreased uptake of CA or an increased excretion. Analyzing the DCE-MRI data with mechanistic mathematical modelling has the possibility of investigating such a differentiation.Subjects and methods88 patients with diffuse liver disease were examined using DCE-MRI (1.5 T Philips Achieva, two-point Dixon, TR=6.5 ms, TE=2.3/4.6 ms, FA=13) after a bolus injection of Gd-EOB-DTPA, followed by a liver biopsy. Regions of interest were placed within the liver, spleen and veins and a whole-body mechanistic pharmacokinetic model2 was fitted to the data. The fitted parameters in the model correspond to the rate of CA transport between different compartments, e.g. hepatocytes, blood plasma, and bile (Fig. 1).ResultsAs can be seen in Fig. 2, the parameter corresponding to the transport of CA from the blood plasma to the hepatocytes, kph, is lower for patients with advanced fibrosis (p=0.01). Fig. 3 shows that the parameter corresponding to the CA excretion into the bile, khb, is higher for patients with advanced fibrosis (p<0.01).Discussion/ConclusionThis work shows that the decreased signal intensity in DCE-MRI images in patients with advanced fibrosis depends on both a decreased uptake of CA in the hepatocytes and an increased excretion into the bile. Similar results have also been observed in a rat study3. In that study, rats with induced cirrhosis had a higher MRP2-activity than the healthy control rats.References1Norén et al: Eur. Radiol, 23(1), 174-181, 2013.2Forsgren et al: PloS One, 9(4): e95700, 2014.3Tsuda & Matsui: Radiol, 256(3): 767-773, 2010.
  •  
4.
  • Forsgren, Mikael (författare)
  • The Non-Invasive Liver Biopsy : Determining Hepatic Function in Diffuse and Focal LiverDisease
  • 2017
  • Doktorsavhandling (övrigt vetenskapligt/konstnärligt)abstract
    • The liver is one of the largest organs within the human body and it handles many vital tasks such as nutrient processing, toxin removal, and synthesis of important proteins. The number of people suffering from chronic liver disease is on the rise, likely due to the present ‘western’ lifestyle. As disease develops in the liver there are pathophysiological manifestations within the liver parenchyma that are both common and important to monitor. These manifestations include inflammation, fatty infiltration (steatosis), excessive scar tissue formation (fibrosis and cirrhosis), and iron loading. Importantly, as the disease progresses there is concurrent loss of liver function. Furthermore, postoperative liver function insufficiency is an important concern when planning surgical treatment of the liver, because it is associated with both morbidity and mortality. Liver function can also be hampered due to drug-induced injuries, an important aspect to consider in drug-development.Currently, an invasive liver needle biopsy is required to determine the aetiology and to stage or grade the pathophysiological manifestations. There are important limitations with the biopsy, which include, risk of serious complications, mortality, morbidity, inter- and intra-observer variability, sampling error, and sampling variability. Cleary, it would be beneficial to be able investigate the pathophysiological manifestations accurately, non-invasively, and on regional level.Current available laboratory liver function blood panels are typically insufficient and often only indicate damage at a late stage. Thus, it would be beneficial to have access to biomarkers that are both sensitive and responds to early changes in liver function in both clinical settings and for the pharmaceutical industry and regulatory agencies.The main aim of this thesis was to develop and evaluate methods that can be used for a ‘non-invasive liver biopsy’ using magnetic resonance (MR). We also aimed to develop sensitive methods for measure liver function based on gadoxetate-enhanced MR imaging (MRI).The presented work is primarily based on a prospective study on c. 100 patients suffering from chronic liver disease of varying aetiologies recruited due to elevated liver enzyme levels, without clear signs of decompensated cirrhosis. Our results show that the commonly used liver fat cut-off for diagnosing steatosis should be lowered from 5% to 3% when using MR proton-density fat fraction (PDFF). We also show that MR elastography (MRE) is superior in staging fibrosis.Finally we presented a framework for quantifying liver function based on gadoxetate-enhanced MRI. The method is based on clinical images and a clinical approved contrast agent (gadoxetate). The framework consists of; state-of the-art image reconstruction and correction methods, a mathematical model, and a precise model parametrization method. The model was developed and validated on healthy subjects. Thereafter the model was found applicable on the chronic liver disease cohort as well as validated using gadoxetate levels in biopsy samples and blood samples. The liver function parameters correlated with clinical markers for liver function and liver fibrosis (used as a surrogate marker for liver function).In summary, it should be possible to perform a non-invasive liver biopsy using: MRI-PDFF for liver fat and iron loading, MRE for liver fibrosis and possibly also inflammation, and measure liver function using the presented framework for analysing gadoxetate-enhanced MRI. With the exception of an MREtransducer no additional hardware is required on the MR scanner. The liver function method is likely to be useful both in a clinical setting and in pharmaceutical trials.
  •  
5.
  • Blystad, Ida, et al. (författare)
  • Quantitative MRI for Analysis of Active Multiple Sclerosis Lesions without Gadolinium-Based Contrast Agent
  • 2016
  • Ingår i: American Journal of Neuroradiology. - : American Society of Neuroradiology (ASNR). - 0195-6108 .- 1936-959X. ; 37:1, s. 94-100
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND AND PURPOSE: Contrast-enhancing MS lesions are important markers of active inflammation in the diagnostic work-up of MS and in disease monitoring with MR imaging. Because intravenous contrast agents involve an expense and a potential risk of adverse events, it would be desirable to identify active lesions without using a contrast agent. The purpose of this study was to evaluate whether pre-contrast injection tissue-relaxation rates and proton density of MS lesions, by using a new quantitative MR imaging sequence, can identify active lesions.MATERIALS AND METHODS: Forty-four patients with a clinical suspicion of MS were studied. MR imaging with a standard clinical MS protocol and a quantitative MR imaging sequence was performed at inclusion (baseline) and after 1 year. ROIs were placed in MS lesions, classified as nonenhancing or enhancing. Longitudinal and transverse relaxation rates, as well as proton density were obtained from the quantitative MR imaging sequence. Statistical analyses of ROI values were performed by using a mixed linear model, logistic regression, and receiver operating characteristic analysis.RESULTS: Enhancing lesions had a significantly (P < .001) higher mean longitudinal relaxation rate (1.22 ± 0.36 versus 0.89 ± 0.24), a higher mean transverse relaxation rate (9.8 ± 2.6 versus 7.4 ± 1.9), and a lower mean proton density (77 ± 11.2 versus 90 ± 8.4) than nonenhancing lesions. An area under the receiver operating characteristic curve value of 0.832 was obtained.CONCLUSIONS: Contrast-enhancing MS lesions often have proton density and relaxation times that differ from those in nonenhancing lesions, with lower proton density and shorter relaxation times in enhancing lesions compared with nonenhancing lesions.
  •  
6.
  • Tapper, Sofie, et al. (författare)
  • Retrospective artifact elimination in MEGA-PRESS using a correlation approach
  • 2019
  • Ingår i: Magnetic Resonance in Medicine. - : John Wiley & Sons. - 0740-3194 .- 1522-2594. ; 81:4, s. 2223-2237
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo develop a method for retrospective artifact elimination of MRS data. This retrospective method was based on an approach that combines jackknife analyses with the correlation of spectral windows, and therefore termed “JKC.”MethodsTwelve healthy volunteers performed 3 separate measurement protocols using a 3T MR system. One protocol consisted of 2 cerebellar MEGA‐PRESS measurements: 1 reference and 1 measurement including head movements. One‐third of the artifact‐influenced datasets were treated as training data for the implementation the JKC method, and the rest were used for validation.ResultsThe implemented JKC method correctly characterized most of the validation data. Additionally, after elimination of the detected artifacts, the resulting concentrations were much closer to those computed for the reference datasets. Moreover, when the JKC method was applied to the reference data, the estimated concentrations were not affected, compared with standard averaging.ConclusionThe implemented JKC method can be applied without any extra cost to MRS data, regardless of whether the dataset has been contaminated by artifacts. Furthermore, the results indicate that the JKC method could be used as a quality control of a dataset, or as an indication of whether a shift in voxel placement has occurred during the measurement.
  •  
7.
  • Blystad, Ida, et al. (författare)
  • Synthetic MRI of the brain in a clinical setting
  • 2012
  • Ingår i: Acta Radiologica. - : Sage Publications. - 0284-1851 .- 1600-0455. ; 53:10, s. 1158-1163
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:Conventional magnetic resonance imaging (MRI) has relatively long scan times for routine examinations, and the signal intensity of the images is related to the specific MR scanner settings. Due to scanner imperfections and automatic optimizations, it is impossible to compare images in terms of absolute image intensity. Synthetic MRI, a method to generate conventional images based on MR quantification, potentially both decreases examination time and enables quantitative measurements.PURPOSE:To evaluate synthetic MRI of the brain in a clinical setting by assessment of the contrast, the contrast-to-noise ratio (CNR), and the diagnostic quality compared with conventional MR images.MATERIAL AND METHODS:Twenty-two patients had synthetic imaging added to their clinical MR examination. In each patient, 12 regions of interest were placed in the brain images to measure contrast and CNR. Furthermore, general image quality, probable diagnosis, and lesion conspicuity were investigated.RESULTS:Synthetic T1-weighted turbo spin echo and T2-weighted turbo spin echo images had higher contrast but also a higher level of noise, resulting in a similar CNR compared with conventional images. Synthetic T2-weighted FLAIR images had lower contrast and a higher level of noise, which led to a lower CNR. Synthetic images were generally assessed to be of inferior image quality, but agreed with the clinical diagnosis to the same extent as the conventional images. Lesion conspicuity was higher in the synthetic T1-weighted images, which also had a better agreement with the clinical diagnoses than the conventional T1-weighted images.CONCLUSION:Synthetic MR can potentially shorten the MR examination time. Even though the image quality is perceived to be inferior, synthetic images agreed with the clinical diagnosis to the same extent as the conventional images in this study.
  •  
8.
  • Karlsson, Markus, et al. (författare)
  • Diffuse Liver Disease: Measurements of Liver Trace Metal Concentrations and R2* Relaxation Rates
  • 2016
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - : Springer. - 0968-5243 .- 1352-8661. ; 29:1, s. S395-S395
  • Tidskriftsartikel (refereegranskat)abstract
    • IntroductionOver the past decade, several methods for measuring of liver iron content (LIC) non-invasively with MRI have been developed and verified. The most promising methods uses relaxometry, measuring either R2- or R2* relaxation rate in the liver1,2. For instance, several studies have shown that there seems to be a linear relationship between R2* and LIC1. However, few of these studies have measured the liver content of other metals, which could also affect the relaxation rates. The goal of this study was to investigate if any trace metals, other than iron could affect the R2* relaxation rate in liver tissue in a patients with diffuse liver disease.Subjects and methods75 patients with suspected diffuse liver disease underwent an MRI examination followed by a liver biopsy the same day. The R2* relaxation rate of the water protons in the liver was measured using an axial 3D multi-slice fat-saturated multi-echo turbo field echo sequence (TE=4.60/9.20/13.80/18.40/23.00ms). Regions of interest (ROI) were drawn and R2* was estimated by fitting the mean signal intensity from the ROIs to a mono-exponential decay model. The biopsies were freeze dried and the concentrations of iron, manganese, copper, cobalt and gadolinium were measured using Inductively Coupled Plasma Sector Field Mass Spectrometry (ICP-SFMS). A multiple linear regression analysis was applied to determine which of the measured metals significantly affected the relaxation rate.ResultsA linear regression with the LIC and R2* showed a reasonable fit (Figure 1). The multiple linear regression analysis (Table 1) showed that iron as well as manganese had a significant affect on R2*. Unlike iron however, the regression coefficient of manganese was negative, meaning that an increasing manganese concentration gave a shorter R2* relaxation rate. The same trend can be seen when plotting the manganese concentration against R2* (Figure 2).
  •  
9.
  • Kihlberg, Johan, Medicine doktor, 1970-, et al. (författare)
  • Magnetic resonance imaging incidents are severely underreported : a finding in a multicentre interview survey
  • 2022
  • Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 32:1, s. 477-488
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives: The purpose of this study was to develop a procedure to investigate the occurrence, character and causes of magnetic resonance (MR) imaging incidents. Methods: A semi-structured questionnaire was developed containing details such as safety zones, examination complexity, staff MR knowledge, staff categories, and implementation of EU directive 2013/35. We focused on formally reported incidents that had occurred during 2014–2019, and unreported incidents during one year. Thirteen clinical MR units were visited, and the managing radiographer was interviewed. Open questions were analysed using conventionally adopted content analysis. Results: Thirty-seven written reports for 5 years and an additional 12 oral reports for 1 year were analysed. Only 38% of the incidents were reported formally. Some of these incidents were catastrophic. Negative correlations were observed between the number of annual incidents (per scanner) and staff MR knowledge (Spearman’s rho − 0.41, p < 0.05) as well as the number of MR physicists per scanner (− 0.48, p < 0.05). It was notable that only half of the sites had implemented the EU directive. Quotes like ‘Burns are to be expected in MR’ and not even knowing the name of the incident reporting system suggested an inadequate safety culture. Finally, there was a desire among staff for MR safety education. Conclusions: MR-related incidents were greatly underreported, and some incidents could have had catastrophic outcomes. There is a great desire among radiographers to enhance the safety culture, but to achieve this, much more accessible education is required, as well as focused involvement of the management of the operations. Key Points: • Only one in three magnetic resonance–related incidents were reported. • Several magnetic resonance incidents could have led to catastrophic consequences. • Much increased knowledge about magnetic resonance safety is needed by radiologists and radiographers.
  •  
10.
  • West, Janne, et al. (författare)
  • Normal Appearing and Diffusely Abnormal White Matter in Patients with Multiple Sclerosis, Assessed with Quantitative MR : Optimization for clinical usage
  • 2014
  • Ingår i: PLOS ONE. - : Public Library of Science. - 1932-6203. ; 9:4, s. e95161-
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Magnetic Resonance Imaging is a sensitive technique for detecting white matter (WM) MS lesions, but the relation with clinical disability is low. Because of this, changes in both ‘normal appearing white matter’ (NAWM) and ‘diffusely abnormal white matter’ (DAWM) have been of interest in recent years. MR techniques, including quantitative magnetic resonance imaging (qMRI) and quantitative magnetic resonance spectroscopy (qMRS), have been developed in order to detect and  quantify such changes.In this study, a combination of qMRI and qMRS was used to investigate NAWM and DAWM in typical MS patients and in MS patients with low number of WM lesions. Patient data were compared to ‘normal white matter’ (NWM) in healthy controls.Methods: QMRI and qMRS measurements were performed on a 1.5T Philips MR-scanner. 35 patients with clinically definite MS and 20 healthy controls were included. Fifteen of the patients showed few WM lesions (‘MRIneg‘) and 20 showed radiologically typical findings (‘MRIpos’). QMRI properties were determined in ROIs of NAWM, DAWM and WM lesions in the MS groups and of NWM in controls. Descriptive statistical analysis and comparisons were performed. Correlations were calculated between qMRI measurements and (1) clinical parameters and (2) WM metabolite concentrations. Regression analyses were performed with brain parenchyma fraction and MSSS.Results: NAWM in the MRIneg group was significantly different from NAWM in the MRIpos group and NWM. In addition, R1 and R2 of NAWM in the MRIpos group correlated negatively with EDSS and MSSS. DAWM was significantly different from NWM, but similar in the two MS groups. N-acetyl aspartate correlated negatively with R1 and R2 in MRIneg. Finally, R2 of DAWM was associated with BPF.Conclusions: Changes in NAWM and DAWM are independent pathological entities in the disease. Combined qMRI and qMRS measurements of NAWM and DAWM provide important markers for disease status.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 74
Typ av publikation
konferensbidrag (36)
tidskriftsartikel (26)
doktorsavhandling (9)
annan publikation (2)
patent (1)
Typ av innehåll
övrigt vetenskapligt/konstnärligt (44)
refereegranskat (29)
populärvet., debatt m.m. (1)
Författare/redaktör
Vogel, HJ (16)
Dahlqvist Leinhard, ... (14)
Lundberg, Peter, 195 ... (11)
Forsgren, Mikael (11)
Kechagias, Stergios (9)
visa fler...
Smedby, Örjan (7)
Dahlqvist Leinhard, ... (7)
Tisell, Anders, 1981 ... (7)
Borga, Magnus (6)
Norén, Bengt (6)
Tisell, Anders (6)
Dahlström, Nils (6)
Landtblom, Anne-Mari ... (5)
Ekstedt, Mattias (5)
Romu, Thobias (5)
Larsson, Elna-Marie (4)
Lundberg, Peter, Pro ... (4)
Almer, Sven (4)
Blystad, Ida (4)
Karlsson, Markus, 19 ... (4)
Smedby, Örjan, 1956- (3)
Ernerudh, Jan (3)
Blystad, Ida, 1972- (3)
Roy, S (3)
Warntjes, Marcel Jan ... (3)
Karlsson, Markus (3)
Engström, Maria, 195 ... (3)
Dahlström, Nils, 196 ... (3)
Norén, Bengt, 1955- (3)
Nasr, Patrik (2)
Kihlberg, Johan (2)
Smedby, Örjan, Profe ... (2)
Ekstedt, Mattias, 19 ... (2)
Andersson, Thord (2)
Backlund, EO (2)
Icenhour, Adriane (2)
Bednarska, Olga, 197 ... (2)
Tapper, Sofie, 1989- (2)
Walter, Susanna, 196 ... (2)
Ignatova, Simone (2)
Tapper, Sofie (2)
Nyström, Fredrik (2)
Ho, C (2)
West, Janne (2)
Smedby, Örjan, Profe ... (2)
Kihlberg, Johan, 197 ... (2)
Lindstam, H (2)
Stephenson, J (2)
Germann, MW (2)
visa färre...
Lärosäte
Linköpings universitet (72)
Uppsala universitet (6)
Kungliga Tekniska Högskolan (5)
Umeå universitet (3)
Göteborgs universitet (2)
Lunds universitet (2)
visa fler...
Karolinska Institutet (2)
visa färre...
Språk
Engelska (71)
Svenska (3)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (74)
Teknik (9)
Naturvetenskap (4)
Samhällsvetenskap (1)
Humaniora (1)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy