SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology) ;hsvcat:2;pers:(Johansson Carina B. 1955)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Medical Biotechnology) > Teknik > Johansson Carina B. 1955

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Sarve, Hamid, et al. (författare)
  • Methods for visualization of bone tissue in the proximity of implants
  • 2010
  • Ingår i: Computer vision and graphics. - Berlin : Springer. - 9783642159060 ; 6375, s. 243-250
  • Konferensbidrag (refereegranskat)abstract
    • In this work we present two methods for visualization of SRμCT-scanned 3D volumes of screw-shaped bone implant samples: thread fly-through and 2D unfolding. The thread fly-through generates an animation by following the thread helix and extracting slices along it. Relevant features, such as bone ratio and bone implant contact, are computed for each slice of the animation and displayed as graphs beside the animation. The 2D unfolding, on the other hand, maps the implant surface onto which feature information is projected to a 2D image, providing an instant overview of the whole implant. The unfolding is made area-preserving when appropriate. These visualization methods facilitate better understanding of the bone-implant integration and provides a good platform for communication between involved experts.
  •  
2.
  • Franco Tabares, Sebastian, et al. (författare)
  • Effect of airborne-particle abrasion and polishing on novel translucent zirconias: Surface morphology, phase transformation and insights into bonding
  • 2021
  • Ingår i: Journal of Prosthodontic Research. - : Japan Prosthodontic Society. - 1883-1958 .- 2212-4632. ; 65:1, s. 97-105
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The purpose this study was to investigate the effect of Kern ' s air-borne particle abrasion protocol (KAPA) and polishing on two translucent zirconias (4Y, 5Y-zirconias) compared to a traditional zirconia (3Y-zirconia). Methods: Two different surface treatments were analysed by X-ray diffraction (XRD) and interferometry 1) KAPA (0.1 MPa, 50 mu m alumina, 10-12 mm distance, 15 sec and 30 sec and cleaning in ultrasound using isopropyl alcohol 99%) and 2) Clinical-delivery polishing paste (Zircon Brite, Dental Ventures, USA). Shear-bond strength tests (SBS's) were performed with a highly polished and virtually flat surface in combination with a 10-MDP based cement and a surface modified by KAPA in combination with zinc phosphate cement. The SBS was expressed in terms of MPa. Results: The mean values for monoclinic content were 13 wt%, 7 wt% and 2 wt% for 3Y-, 4Y- and 5Y-zirconias respectively, no differences were found between 15 and 30 seconds. Polishing did not result in phase transformation to monoclinic phase in any of the zirconias. The rhombohedral phase was identified in all types of zirconias regardless of surface treatment. Shear-bond strength tests showed 5 MPa for polished/10-MDP based cement and 3 MPa for KAPA/Zinc phosphate. Statistically significant differences were found between the two different surface treatments but not between the types of zirconias. Conclusions: KAPA for 15 sec seems to be equal to 30 sec regarding morphology and phase transformation. Sole micro-retention appears not to be fully responsible for the bonding phenomena of 10-MDP and zirconia that underwent KAPA.
  •  
3.
  • Sarve, Hamid, et al. (författare)
  • Extracting 3D information on bone remodeling in the proximity of titanium implants in SRμCT image volumes.
  • 2011
  • Ingår i: Computer methods and programs in biomedicine. - : Elsevier BV. - 1872-7565 .- 0169-2607. ; 102:1, s. 25-34
  • Tidskriftsartikel (refereegranskat)abstract
    • Bone-implant integration is measured in several ways. Traditionally and routinely, 2D histological sections of samples, containing bone and the biomaterial, are stained and analyzed using a light microscope. Such histological section provides detailed cellular information about the bone regeneration in the proximity of the implant. However, this information reflects the integration in only a very small fraction, a 10 μm thick slice, of the sample. In this study, we show that feature values quantified on 2D sections are highly dependent on the orientation and the placement of the section, suggesting that a 3D analysis of the whole sample is of importance for a more complete judgment of the bone structure in the proximity of the implant. We propose features describing the 3D data by extending the features traditionally used for 2D-analysis. We present a method for extracting these features from 3D image data and we measure them on five 3D SRμCT image volumes. We also simulate cuts through the image volume positioned at all possible section positions. These simulations show that the measurement variations due to the orientation of the section around the center line of the implant are about 30%.
  •  
4.
  • Sul, Young-Taeg, 1960, et al. (författare)
  • A novel in vivo method for quantifying the interfacial biochemical bond strength of bone implants
  • 2010
  • Ingår i: Journal of the Royal Society Interface. - London, United Kingdom : Royal Society. - 1742-5689 .- 1742-5662. ; 7:42, s. 81-90
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantifying the in vivo interfacial biochemical bond strength of bone implants is a biological challenge. We have developed a new and novel in vivo method to identify an interfacial biochemical bond in bone implants and to measure its bonding strength. This method, named biochemical bond measurement (BBM), involves a combination of the implant devices to measure true interfacial bond strength and surface property controls, and thus enables the contributions of mechanical interlocking and biochemical bonding to be distinguished from the measured strength values. We applied the BBM method to a rabbit model, and observed great differences in bone integration between the oxygen (control group) and magnesium (test group) plasma immersion ion-implanted titanium implants (0.046 versus 0.086 MPa, n=10, p=0.005). The biochemical bond in the test implants resulted in superior interfacial behaviour of the implants to bone: (i) close contact to approximately 2 μm thin amorphous interfacial tissue, (ii) pronounced mineralization of the interfacial tissue, (iii) rapid bone healing in contact, and (iv) strong integration to bone. The BBM method can be applied to in vivo experimental models not only to validate the presence of a biochemical bond at the bone–implant interface but also to measure the relative quantity of biochemical bond strength. The present study may provide new avenues for better understanding the role of a biochemical bond involved in the integration of bone implants.
  •  
5.
  • Sarve, Hamid, et al. (författare)
  • Introducing a novel analysis technique for osseointegrated dental implants retrieved 29 years postsurgery
  • 2013
  • Ingår i: Clinical Implant Dentistry and Related Research. - : Wiley-Blackwell. - 1523-0899 .- 1708-8208. ; 15:4, s. 538-549
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate osseointegration of oral implants, which were retrieved from a patient after 29 years in situ, we use novel three-dimensional analysis methods and visualization techniques that supplement conventional two-dimensional analysis. Materials and Methods: The sample processing involved nondecalcification and embedment in resin. Conventional two-dimensional histomorphometrical methods were conducted. Additionally, the quantification was extended to three-dimensional by using synchrotron radiation micro-computed tomography (SRmCT) technique and two relevant visualization methods for the three-dimensional data were introduced. Results: The three-dimensional results involved three-dimensional quantification and visualization of two implant samples with methods beyond state-of-the-art. Traditional two-dimensional histomorphometrical results revealed a mean bone-implant contact (BIC) of about 50%. In most samples, bone area (BA) was lower inside the treads compared with out-folded mirror images, which were confirmed by the three-dimensional quantification. The BIC along four selected regions showed highest percentages in the bottom/valley region and lowest in the thread-peak region. Qualitative observations revealed ongoing bone remodeling areas in all samples. The apical hole demonstrated high osseointegration. Conclusion: The novel techniques including an animation and an out-folding of BIC and BA enabled a simultaneous visualization of the three-dimensional material obtained from SRmCT data. However, the two-dimensional histological sections were needed for qualitative and quantitative evaluation of osseointegration and, thus, both methods are considered equally important.
  •  
6.
  • Kassapidou, Maria, et al. (författare)
  • Cobalt-chromium alloys in fixed prosthodontics in Sweden
  • 2017
  • Ingår i: Acta Biomaterialia Odontologica Scandinavica. - : Informa UK Limited. - 2333-7931. ; 3:1, s. 53-62
  • Tidskriftsartikel (refereegranskat)abstract
    • Aim: The aim of this study was to compile the usage of Co-Cr alloys in fixed prosthodontics (FP) among dental laboratories in Sweden.Methods: From March to October 2015, questionnaires were sent to 542 registered dental laboratories in Sweden. The questionnaires were divided in two parts, one for fixed dental-supported prosthodontics (FDP) and one for fixed implant-supported prosthodontics (FIP). Reminders were sent three times.Results: In total of 542 dental laboratories, 55% answered the questionnaires. Most dental laboratories use Co-Cr in FP, 134 (74%) in FDP and 89(66%) in FIP. The laboratories used Co-Cr alloys of various compositions in the prostheses, 35 for FDP and 30 for FIP. The most commonly used Co-Cr alloys for tooth-supported FDPs were (a) Wirobond® 280, (b) Cara SLM and (c) Wirobond® C. For implant-supported frameworks the frequently used alloys were: (a) Cara SLM, (b) Cara Milled and (c) Wirobond® 280. Except for the difference in composition of these alloys, they were also manufactured with various techniques. In tooth-supported prostheses the dominating technique was the cast technique while newer techniques as laser-sintering and milling were more commonly reported for implant-supported constructions. A fourth technique; the ‘pre-state’ milling was reported in FDP.Conclusion: More than 30 different Co-Cr alloys were reported as being used in FP. Thus, there is a need for studies exploring the mechanical and physical behavior and the biological response to the most commonly used Co-Cr alloys.
  •  
7.
  • Reinedahl, David, et al. (författare)
  • Aseptic Ligatures Induce Marginal Peri-Implant Bone Loss-An 8-Week Trial in Rabbits
  • 2019
  • Ingår i: Journal of Clinical Medicine. - : MDPI. - 2077-0383. ; 8:8
  • Tidskriftsartikel (refereegranskat)abstract
    • The clinical value of ligature-induced experimental peri-implantitis studies has been questioned due to the artificial nature of the model. Despite repeated claims that ligatures of silk, cotton and other materials may not induce bone resorption by themselves; a recent review showed that the tissue reaction toward them has not been investigated. Hence, the current study aimed to explore the hard and soft tissue reactions toward commonly used ligature materials. A total of 60 dental implants were inserted into the femur ( = 20) and tibia ( = 40) of 10 rabbits. The femoral implants were ligated with sterile 3-0 braided silk in one leg and sterile cotton retraction chord in the other leg. The tibial implants were ligated with silk or left as non-ligated controls. All wounds were closed in layers. After a healing time of 8 weeks, femoral (silk versus cotton) and proximal tibial (silk versus non-ligated control) implants were investigated histologically. Distal tibial (silk versus non-ligated control) implants were investigated with real time polymerase chain reaction (qPCR). The distance from the implant-top to first bone contact point was longer for silk ligated implants compared to non-ligated controls ( = 0.007), but did not vary between cotton and silk. The ligatures triggered an immunological reaction with cell infiltrates in close contact with the ligature materials, adjacent soft tissue encapsulation and bone resorption. qPCR further demonstrated an upregulated immune response toward the silk ligatures compared to non-ligated controls. Silk and cotton ligatures provoke foreign body reactions of soft tissue encapsulation type and bone resorption around implants in the absence of plaque.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy